<?xml version="1.0"?>
<lsccip:ip version="1.0"
    xmlns:lsccip="http://www.latticesemi.com/XMLSchema/Radiant/ip"
    xmlns:xi="http://www.w3.org/2001/XInclude">

  <lsccip:general>
    <lsccip:vendor>latticesemi.com</lsccip:vendor>
    <lsccip:library>module</lsccip:library>
    <lsccip:name>ahb_lite_interconnect</lsccip:name>
    <lsccip:display_name>AHB Lite Interconnect</lsccip:display_name>
    <lsccip:version>1.6.0</lsccip:version>
    <lsccip:category>Processors_Controllers_and_Peripherals</lsccip:category>
    <lsccip:keywords>BusType_AHB-Lite</lsccip:keywords>
    <lsccip:min_radiant_version>3.1</lsccip:min_radiant_version>
    <lsccip:min_esi_version>2022.1</lsccip:min_esi_version>
    <lsccip:supported_products>
	  <lsccip:supported_family name="*"/>
    </lsccip:supported_products>
    <lsccip:supported_platforms>
      <lsccip:supported_platform name="radiant"/>
      <lsccip:supported_platform name="esi"/>
    </lsccip:supported_platforms>
  </lsccip:general>

  <lsccip:settings>
    <!-- General Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "TOTAL_MASTER_CNT"
                    type               = "param"
                    value_type         = "int"
                    default            = "2"
                    options            = "range(1,33)"
                    value_range        = "(1,32)"
                    title              = "Total AHB-Lite Managers"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "TOTAL_SLAVE_CNT"
                    type               = "param"
                    value_type         = "int"
                    default            = "2"
                    options            = "ext_calc_total_slave_range()"
                    value_range        = "(1,32)"
                    title              = "Total AHB-Lite Subordinates"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "M_ADDR_WIDTH"
                    type               = "param"
                    value_type         = "int"
                    default            = "32"
                    options            = "range(11,33)"
                    config_groups      = "'SystemBuilder'"
                    title              = "Manager Address Width(bits)"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "FULL_DECODE_EN_IN"
                    type               = "input"
                    value_type         = "bool"
                    default            = "True"
                    editable           = "False"
                    title              = "Full Address Decoding up to 1kB"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "FULL_DECODE_EN"
                    type               = "param"
                    value_type         = "int"
                    value_expr         = "1 if (FULL_DECODE_EN_IN == True) else 0"
                    config_groups      = "'SystemBuilder'"
                    editable           = "False"
                    hidden             = "True"
                    title              = ""
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "DATA_WIDTH"
                    type               = "param"
                    value_type         = "int"
                    default            = "32"
                    options            = "[8,16,32,64,128,256,512,1024]"
                    title              = "Data Bus Width(bits)"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "OUTREG_EN"
                    type               = "param"
                    value_type         = "bool"
                    default            = "False"
                    editable           = "False"
                    title              = "Registered Output"
    />
    
    <!-- 
    "Early Burst Termination Protection" will be exposed if "Round Robin" is selected on
    any of the subordinates. 
    -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "EARLY_BURST_TERM_PROTECT_INPUT"
                    type               = "input"
                    value_type         = "bool"
                    default            = "False"
                    editable           = "True"
                    hidden             = "True"
                    title              = "Early Burst Termination Protection"
    />
    
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "EARLY_BURST_TERM_PROTECT"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "'1\'b1' if (EARLY_BURST_TERM_PROTECT_INPUT == True) else '1\'b0'"
                    output_formatter   = "nostr"
                    editable           = "False"
                    hidden             = "True"
                    title              = ""
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "m_prio_width"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_clog2(TOTAL_MASTER_CNT)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M_PRIO_WIDTH"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "General"
                    id                 = "FAMILY"
                    type               = "param"
                    value_type         = "string"
                    default            = "LIFCL"
                    value_expr         = "runtime_info.device_info.architecture(1)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "Device Architecture"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s0)"
                    editable           = "en_m0 and en_s0"
                    default            = "True"
                    title              = "Manager 0 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s1)"
                    editable           = "en_m0 and en_s1"
                    default            = "True"
                    title              = "Manager 0 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s2)"
                    editable           = "en_m0 and en_s2"
                    default            = "True"
                    title              = "Manager 0 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s3)"
                    editable           = "en_m0 and en_s3"
                    default            = "True"
                    title              = "Manager 0 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s4)"
                    editable           = "en_m0 and en_s4"
                    default            = "True"
                    title              = "Manager 0 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s5)"
                    editable           = "en_m0 and en_s5"
                    default            = "True"
                    title              = "Manager 0 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s6)"
                    editable           = "en_m0 and en_s6"
                    default            = "True"
                    title              = "Manager 0 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s7)"
                    editable           = "en_m0 and en_s7"
                    default            = "True"
                    title              = "Manager 0 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s8)"
                    editable           = "en_m0 and en_s8"
                    default            = "True"
                    title              = "Manager 0 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s9)"
                    editable           = "en_m0 and en_s9"
                    default            = "True"
                    title              = "Manager 0 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s10)"
                    editable           = "en_m0 and en_s10"
                    default            = "True"
                    title              = "Manager 0 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s11)"
                    editable           = "en_m0 and en_s11"
                    default            = "True"
                    title              = "Manager 0 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s12)"
                    editable           = "en_m0 and en_s12"
                    default            = "True"
                    title              = "Manager 0 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s13)"
                    editable           = "en_m0 and en_s13"
                    default            = "True"
                    title              = "Manager 0 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s14)"
                    editable           = "en_m0 and en_s14"
                    default            = "True"
                    title              = "Manager 0 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s15)"
                    editable           = "en_m0 and en_s15"
                    default            = "True"
                    title              = "Manager 0 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s16)"
                    editable           = "en_m0 and en_s16"
                    default            = "True"
                    title              = "Manager 0 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s17)"
                    editable           = "en_m0 and en_s17"
                    default            = "True"
                    title              = "Manager 0 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s18)"
                    editable           = "en_m0 and en_s18"
                    default            = "True"
                    title              = "Manager 0 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s19)"
                    editable           = "en_m0 and en_s19"
                    default            = "True"
                    title              = "Manager 0 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s20)"
                    editable           = "en_m0 and en_s20"
                    default            = "True"
                    title              = "Manager 0 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s21)"
                    editable           = "en_m0 and en_s21"
                    default            = "True"
                    title              = "Manager 0 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s22)"
                    editable           = "en_m0 and en_s22"
                    default            = "True"
                    title              = "Manager 0 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s23)"
                    editable           = "en_m0 and en_s23"
                    default            = "True"
                    title              = "Manager 0 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s24)"
                    editable           = "en_m0 and en_s24"
                    default            = "True"
                    title              = "Manager 0 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s25)"
                    editable           = "en_m0 and en_s25"
                    default            = "True"
                    title              = "Manager 0 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s26)"
                    editable           = "en_m0 and en_s26"
                    default            = "True"
                    title              = "Manager 0 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s27)"
                    editable           = "en_m0 and en_s27"
                    default            = "True"
                    title              = "Manager 0 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s28)"
                    editable           = "en_m0 and en_s28"
                    default            = "True"
                    title              = "Manager 0 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s29)"
                    editable           = "en_m0 and en_s29"
                    default            = "True"
                    title              = "Manager 0 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s30)"
                    editable           = "en_m0 and en_s30"
                    default            = "True"
                    title              = "Manager 0 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "m0_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m0 and en_s31)"
                    editable           = "en_m0 and en_s31"
                    default            = "True"
                    title              = "Manager 0 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 0 Connection Setting"
                    id                 = "M0_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m0_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s0)"
                    editable           = "en_m1 and en_s0"
                    default            = "True"
                    title              = "Manager 1 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s1)"
                    editable           = "en_m1 and en_s1"
                    default            = "True"
                    title              = "Manager 1 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s2)"
                    editable           = "en_m1 and en_s2"
                    default            = "True"
                    title              = "Manager 1 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s3)"
                    editable           = "en_m1 and en_s3"
                    default            = "True"
                    title              = "Manager 1 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s4)"
                    editable           = "en_m1 and en_s4"
                    default            = "True"
                    title              = "Manager 1 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s5)"
                    editable           = "en_m1 and en_s5"
                    default            = "True"
                    title              = "Manager 1 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s6)"
                    editable           = "en_m1 and en_s6"
                    default            = "True"
                    title              = "Manager 1 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s7)"
                    editable           = "en_m1 and en_s7"
                    default            = "True"
                    title              = "Manager 1 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s8)"
                    editable           = "en_m1 and en_s8"
                    default            = "True"
                    title              = "Manager 1 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s9)"
                    editable           = "en_m1 and en_s9"
                    default            = "True"
                    title              = "Manager 1 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s10)"
                    editable           = "en_m1 and en_s10"
                    default            = "True"
                    title              = "Manager 1 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s11)"
                    editable           = "en_m1 and en_s11"
                    default            = "True"
                    title              = "Manager 1 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s12)"
                    editable           = "en_m1 and en_s12"
                    default            = "True"
                    title              = "Manager 1 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s13)"
                    editable           = "en_m1 and en_s13"
                    default            = "True"
                    title              = "Manager 1 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s14)"
                    editable           = "en_m1 and en_s14"
                    default            = "True"
                    title              = "Manager 1 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s15)"
                    editable           = "en_m1 and en_s15"
                    default            = "True"
                    title              = "Manager 1 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s16)"
                    editable           = "en_m1 and en_s16"
                    default            = "True"
                    title              = "Manager 1 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s17)"
                    editable           = "en_m1 and en_s17"
                    default            = "True"
                    title              = "Manager 1 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s18)"
                    editable           = "en_m1 and en_s18"
                    default            = "True"
                    title              = "Manager 1 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s19)"
                    editable           = "en_m1 and en_s19"
                    default            = "True"
                    title              = "Manager 1 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s20)"
                    editable           = "en_m1 and en_s20"
                    default            = "True"
                    title              = "Manager 1 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s21)"
                    editable           = "en_m1 and en_s21"
                    default            = "True"
                    title              = "Manager 1 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s22)"
                    editable           = "en_m1 and en_s22"
                    default            = "True"
                    title              = "Manager 1 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s23)"
                    editable           = "en_m1 and en_s23"
                    default            = "True"
                    title              = "Manager 1 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s24)"
                    editable           = "en_m1 and en_s24"
                    default            = "True"
                    title              = "Manager 1 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s25)"
                    editable           = "en_m1 and en_s25"
                    default            = "True"
                    title              = "Manager 1 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s26)"
                    editable           = "en_m1 and en_s26"
                    default            = "True"
                    title              = "Manager 1 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s27)"
                    editable           = "en_m1 and en_s27"
                    default            = "True"
                    title              = "Manager 1 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s28)"
                    editable           = "en_m1 and en_s28"
                    default            = "True"
                    title              = "Manager 1 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s29)"
                    editable           = "en_m1 and en_s29"
                    default            = "True"
                    title              = "Manager 1 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s30)"
                    editable           = "en_m1 and en_s30"
                    default            = "True"
                    title              = "Manager 1 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "m1_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m1 and en_s31)"
                    editable           = "en_m1 and en_s31"
                    default            = "True"
                    title              = "Manager 1 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 1 Connection Setting"
                    id                 = "M1_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m1_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s0)"
                    editable           = "en_m2 and en_s0"
                    default            = "True"
                    title              = "Manager 2 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s1)"
                    editable           = "en_m2 and en_s1"
                    default            = "True"
                    title              = "Manager 2 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s2)"
                    editable           = "en_m2 and en_s2"
                    default            = "True"
                    title              = "Manager 2 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s3)"
                    editable           = "en_m2 and en_s3"
                    default            = "True"
                    title              = "Manager 2 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s4)"
                    editable           = "en_m2 and en_s4"
                    default            = "True"
                    title              = "Manager 2 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s5)"
                    editable           = "en_m2 and en_s5"
                    default            = "True"
                    title              = "Manager 2 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s6)"
                    editable           = "en_m2 and en_s6"
                    default            = "True"
                    title              = "Manager 2 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s7)"
                    editable           = "en_m2 and en_s7"
                    default            = "True"
                    title              = "Manager 2 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s8)"
                    editable           = "en_m2 and en_s8"
                    default            = "True"
                    title              = "Manager 2 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s9)"
                    editable           = "en_m2 and en_s9"
                    default            = "True"
                    title              = "Manager 2 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s10)"
                    editable           = "en_m2 and en_s10"
                    default            = "True"
                    title              = "Manager 2 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s11)"
                    editable           = "en_m2 and en_s11"
                    default            = "True"
                    title              = "Manager 2 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s12)"
                    editable           = "en_m2 and en_s12"
                    default            = "True"
                    title              = "Manager 2 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s13)"
                    editable           = "en_m2 and en_s13"
                    default            = "True"
                    title              = "Manager 2 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s14)"
                    editable           = "en_m2 and en_s14"
                    default            = "True"
                    title              = "Manager 2 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s15)"
                    editable           = "en_m2 and en_s15"
                    default            = "True"
                    title              = "Manager 2 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s16)"
                    editable           = "en_m2 and en_s16"
                    default            = "True"
                    title              = "Manager 2 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s17)"
                    editable           = "en_m2 and en_s17"
                    default            = "True"
                    title              = "Manager 2 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s18)"
                    editable           = "en_m2 and en_s18"
                    default            = "True"
                    title              = "Manager 2 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s19)"
                    editable           = "en_m2 and en_s19"
                    default            = "True"
                    title              = "Manager 2 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s20)"
                    editable           = "en_m2 and en_s20"
                    default            = "True"
                    title              = "Manager 2 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s21)"
                    editable           = "en_m2 and en_s21"
                    default            = "True"
                    title              = "Manager 2 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s22)"
                    editable           = "en_m2 and en_s22"
                    default            = "True"
                    title              = "Manager 2 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s23)"
                    editable           = "en_m2 and en_s23"
                    default            = "True"
                    title              = "Manager 2 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s24)"
                    editable           = "en_m2 and en_s24"
                    default            = "True"
                    title              = "Manager 2 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s25)"
                    editable           = "en_m2 and en_s25"
                    default            = "True"
                    title              = "Manager 2 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s26)"
                    editable           = "en_m2 and en_s26"
                    default            = "True"
                    title              = "Manager 2 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s27)"
                    editable           = "en_m2 and en_s27"
                    default            = "True"
                    title              = "Manager 2 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s28)"
                    editable           = "en_m2 and en_s28"
                    default            = "True"
                    title              = "Manager 2 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s29)"
                    editable           = "en_m2 and en_s29"
                    default            = "True"
                    title              = "Manager 2 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s30)"
                    editable           = "en_m2 and en_s30"
                    default            = "True"
                    title              = "Manager 2 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "m2_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m2 and en_s31)"
                    editable           = "en_m2 and en_s31"
                    default            = "True"
                    title              = "Manager 2 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 2 Connection Setting"
                    id                 = "M2_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m2_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s0)"
                    editable           = "en_m3 and en_s0"
                    default            = "True"
                    title              = "Manager 3 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s1)"
                    editable           = "en_m3 and en_s1"
                    default            = "True"
                    title              = "Manager 3 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s2)"
                    editable           = "en_m3 and en_s2"
                    default            = "True"
                    title              = "Manager 3 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s3)"
                    editable           = "en_m3 and en_s3"
                    default            = "True"
                    title              = "Manager 3 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s4)"
                    editable           = "en_m3 and en_s4"
                    default            = "True"
                    title              = "Manager 3 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s5)"
                    editable           = "en_m3 and en_s5"
                    default            = "True"
                    title              = "Manager 3 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s6)"
                    editable           = "en_m3 and en_s6"
                    default            = "True"
                    title              = "Manager 3 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s7)"
                    editable           = "en_m3 and en_s7"
                    default            = "True"
                    title              = "Manager 3 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s8)"
                    editable           = "en_m3 and en_s8"
                    default            = "True"
                    title              = "Manager 3 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s9)"
                    editable           = "en_m3 and en_s9"
                    default            = "True"
                    title              = "Manager 3 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s10)"
                    editable           = "en_m3 and en_s10"
                    default            = "True"
                    title              = "Manager 3 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s11)"
                    editable           = "en_m3 and en_s11"
                    default            = "True"
                    title              = "Manager 3 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s12)"
                    editable           = "en_m3 and en_s12"
                    default            = "True"
                    title              = "Manager 3 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s13)"
                    editable           = "en_m3 and en_s13"
                    default            = "True"
                    title              = "Manager 3 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s14)"
                    editable           = "en_m3 and en_s14"
                    default            = "True"
                    title              = "Manager 3 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s15)"
                    editable           = "en_m3 and en_s15"
                    default            = "True"
                    title              = "Manager 3 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s16)"
                    editable           = "en_m3 and en_s16"
                    default            = "True"
                    title              = "Manager 3 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s17)"
                    editable           = "en_m3 and en_s17"
                    default            = "True"
                    title              = "Manager 3 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s18)"
                    editable           = "en_m3 and en_s18"
                    default            = "True"
                    title              = "Manager 3 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s19)"
                    editable           = "en_m3 and en_s19"
                    default            = "True"
                    title              = "Manager 3 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s20)"
                    editable           = "en_m3 and en_s20"
                    default            = "True"
                    title              = "Manager 3 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s21)"
                    editable           = "en_m3 and en_s21"
                    default            = "True"
                    title              = "Manager 3 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s22)"
                    editable           = "en_m3 and en_s22"
                    default            = "True"
                    title              = "Manager 3 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s23)"
                    editable           = "en_m3 and en_s23"
                    default            = "True"
                    title              = "Manager 3 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s24)"
                    editable           = "en_m3 and en_s24"
                    default            = "True"
                    title              = "Manager 3 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s25)"
                    editable           = "en_m3 and en_s25"
                    default            = "True"
                    title              = "Manager 3 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s26)"
                    editable           = "en_m3 and en_s26"
                    default            = "True"
                    title              = "Manager 3 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s27)"
                    editable           = "en_m3 and en_s27"
                    default            = "True"
                    title              = "Manager 3 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s28)"
                    editable           = "en_m3 and en_s28"
                    default            = "True"
                    title              = "Manager 3 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s29)"
                    editable           = "en_m3 and en_s29"
                    default            = "True"
                    title              = "Manager 3 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s30)"
                    editable           = "en_m3 and en_s30"
                    default            = "True"
                    title              = "Manager 3 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "m3_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m3 and en_s31)"
                    editable           = "en_m3 and en_s31"
                    default            = "True"
                    title              = "Manager 3 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 3 Connection Setting"
                    id                 = "M3_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m3_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s0)"
                    editable           = "en_m4 and en_s0"
                    default            = "True"
                    title              = "Manager 4 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s1)"
                    editable           = "en_m4 and en_s1"
                    default            = "True"
                    title              = "Manager 4 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s2)"
                    editable           = "en_m4 and en_s2"
                    default            = "True"
                    title              = "Manager 4 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s3)"
                    editable           = "en_m4 and en_s3"
                    default            = "True"
                    title              = "Manager 4 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s4)"
                    editable           = "en_m4 and en_s4"
                    default            = "True"
                    title              = "Manager 4 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s5)"
                    editable           = "en_m4 and en_s5"
                    default            = "True"
                    title              = "Manager 4 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s6)"
                    editable           = "en_m4 and en_s6"
                    default            = "True"
                    title              = "Manager 4 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s7)"
                    editable           = "en_m4 and en_s7"
                    default            = "True"
                    title              = "Manager 4 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s8)"
                    editable           = "en_m4 and en_s8"
                    default            = "True"
                    title              = "Manager 4 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s9)"
                    editable           = "en_m4 and en_s9"
                    default            = "True"
                    title              = "Manager 4 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s10)"
                    editable           = "en_m4 and en_s10"
                    default            = "True"
                    title              = "Manager 4 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s11)"
                    editable           = "en_m4 and en_s11"
                    default            = "True"
                    title              = "Manager 4 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s12)"
                    editable           = "en_m4 and en_s12"
                    default            = "True"
                    title              = "Manager 4 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s13)"
                    editable           = "en_m4 and en_s13"
                    default            = "True"
                    title              = "Manager 4 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s14)"
                    editable           = "en_m4 and en_s14"
                    default            = "True"
                    title              = "Manager 4 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s15)"
                    editable           = "en_m4 and en_s15"
                    default            = "True"
                    title              = "Manager 4 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s16)"
                    editable           = "en_m4 and en_s16"
                    default            = "True"
                    title              = "Manager 4 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s17)"
                    editable           = "en_m4 and en_s17"
                    default            = "True"
                    title              = "Manager 4 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s18)"
                    editable           = "en_m4 and en_s18"
                    default            = "True"
                    title              = "Manager 4 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s19)"
                    editable           = "en_m4 and en_s19"
                    default            = "True"
                    title              = "Manager 4 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s20)"
                    editable           = "en_m4 and en_s20"
                    default            = "True"
                    title              = "Manager 4 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s21)"
                    editable           = "en_m4 and en_s21"
                    default            = "True"
                    title              = "Manager 4 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s22)"
                    editable           = "en_m4 and en_s22"
                    default            = "True"
                    title              = "Manager 4 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s23)"
                    editable           = "en_m4 and en_s23"
                    default            = "True"
                    title              = "Manager 4 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s24)"
                    editable           = "en_m4 and en_s24"
                    default            = "True"
                    title              = "Manager 4 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s25)"
                    editable           = "en_m4 and en_s25"
                    default            = "True"
                    title              = "Manager 4 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s26)"
                    editable           = "en_m4 and en_s26"
                    default            = "True"
                    title              = "Manager 4 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s27)"
                    editable           = "en_m4 and en_s27"
                    default            = "True"
                    title              = "Manager 4 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s28)"
                    editable           = "en_m4 and en_s28"
                    default            = "True"
                    title              = "Manager 4 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s29)"
                    editable           = "en_m4 and en_s29"
                    default            = "True"
                    title              = "Manager 4 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s30)"
                    editable           = "en_m4 and en_s30"
                    default            = "True"
                    title              = "Manager 4 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "m4_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m4 and en_s31)"
                    editable           = "en_m4 and en_s31"
                    default            = "True"
                    title              = "Manager 4 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 4 Connection Setting"
                    id                 = "M4_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m4_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s0)"
                    editable           = "en_m5 and en_s0"
                    default            = "True"
                    title              = "Manager 5 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s1)"
                    editable           = "en_m5 and en_s1"
                    default            = "True"
                    title              = "Manager 5 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s2)"
                    editable           = "en_m5 and en_s2"
                    default            = "True"
                    title              = "Manager 5 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s3)"
                    editable           = "en_m5 and en_s3"
                    default            = "True"
                    title              = "Manager 5 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s4)"
                    editable           = "en_m5 and en_s4"
                    default            = "True"
                    title              = "Manager 5 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s5)"
                    editable           = "en_m5 and en_s5"
                    default            = "True"
                    title              = "Manager 5 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s6)"
                    editable           = "en_m5 and en_s6"
                    default            = "True"
                    title              = "Manager 5 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s7)"
                    editable           = "en_m5 and en_s7"
                    default            = "True"
                    title              = "Manager 5 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s8)"
                    editable           = "en_m5 and en_s8"
                    default            = "True"
                    title              = "Manager 5 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s9)"
                    editable           = "en_m5 and en_s9"
                    default            = "True"
                    title              = "Manager 5 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s10)"
                    editable           = "en_m5 and en_s10"
                    default            = "True"
                    title              = "Manager 5 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s11)"
                    editable           = "en_m5 and en_s11"
                    default            = "True"
                    title              = "Manager 5 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s12)"
                    editable           = "en_m5 and en_s12"
                    default            = "True"
                    title              = "Manager 5 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s13)"
                    editable           = "en_m5 and en_s13"
                    default            = "True"
                    title              = "Manager 5 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s14)"
                    editable           = "en_m5 and en_s14"
                    default            = "True"
                    title              = "Manager 5 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s15)"
                    editable           = "en_m5 and en_s15"
                    default            = "True"
                    title              = "Manager 5 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s16)"
                    editable           = "en_m5 and en_s16"
                    default            = "True"
                    title              = "Manager 5 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s17)"
                    editable           = "en_m5 and en_s17"
                    default            = "True"
                    title              = "Manager 5 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s18)"
                    editable           = "en_m5 and en_s18"
                    default            = "True"
                    title              = "Manager 5 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s19)"
                    editable           = "en_m5 and en_s19"
                    default            = "True"
                    title              = "Manager 5 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s20)"
                    editable           = "en_m5 and en_s20"
                    default            = "True"
                    title              = "Manager 5 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s21)"
                    editable           = "en_m5 and en_s21"
                    default            = "True"
                    title              = "Manager 5 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s22)"
                    editable           = "en_m5 and en_s22"
                    default            = "True"
                    title              = "Manager 5 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s23)"
                    editable           = "en_m5 and en_s23"
                    default            = "True"
                    title              = "Manager 5 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s24)"
                    editable           = "en_m5 and en_s24"
                    default            = "True"
                    title              = "Manager 5 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s25)"
                    editable           = "en_m5 and en_s25"
                    default            = "True"
                    title              = "Manager 5 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s26)"
                    editable           = "en_m5 and en_s26"
                    default            = "True"
                    title              = "Manager 5 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s27)"
                    editable           = "en_m5 and en_s27"
                    default            = "True"
                    title              = "Manager 5 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s28)"
                    editable           = "en_m5 and en_s28"
                    default            = "True"
                    title              = "Manager 5 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s29)"
                    editable           = "en_m5 and en_s29"
                    default            = "True"
                    title              = "Manager 5 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s30)"
                    editable           = "en_m5 and en_s30"
                    default            = "True"
                    title              = "Manager 5 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "m5_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m5 and en_s31)"
                    editable           = "en_m5 and en_s31"
                    default            = "True"
                    title              = "Manager 5 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 5 Connection Setting"
                    id                 = "M5_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m5_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s0)"
                    editable           = "en_m6 and en_s0"
                    default            = "True"
                    title              = "Manager 6 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s1)"
                    editable           = "en_m6 and en_s1"
                    default            = "True"
                    title              = "Manager 6 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s2)"
                    editable           = "en_m6 and en_s2"
                    default            = "True"
                    title              = "Manager 6 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s3)"
                    editable           = "en_m6 and en_s3"
                    default            = "True"
                    title              = "Manager 6 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s4)"
                    editable           = "en_m6 and en_s4"
                    default            = "True"
                    title              = "Manager 6 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s5)"
                    editable           = "en_m6 and en_s5"
                    default            = "True"
                    title              = "Manager 6 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s6)"
                    editable           = "en_m6 and en_s6"
                    default            = "True"
                    title              = "Manager 6 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s7)"
                    editable           = "en_m6 and en_s7"
                    default            = "True"
                    title              = "Manager 6 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s8)"
                    editable           = "en_m6 and en_s8"
                    default            = "True"
                    title              = "Manager 6 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s9)"
                    editable           = "en_m6 and en_s9"
                    default            = "True"
                    title              = "Manager 6 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s10)"
                    editable           = "en_m6 and en_s10"
                    default            = "True"
                    title              = "Manager 6 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s11)"
                    editable           = "en_m6 and en_s11"
                    default            = "True"
                    title              = "Manager 6 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s12)"
                    editable           = "en_m6 and en_s12"
                    default            = "True"
                    title              = "Manager 6 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s13)"
                    editable           = "en_m6 and en_s13"
                    default            = "True"
                    title              = "Manager 6 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s14)"
                    editable           = "en_m6 and en_s14"
                    default            = "True"
                    title              = "Manager 6 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s15)"
                    editable           = "en_m6 and en_s15"
                    default            = "True"
                    title              = "Manager 6 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s16)"
                    editable           = "en_m6 and en_s16"
                    default            = "True"
                    title              = "Manager 6 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s17)"
                    editable           = "en_m6 and en_s17"
                    default            = "True"
                    title              = "Manager 6 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s18)"
                    editable           = "en_m6 and en_s18"
                    default            = "True"
                    title              = "Manager 6 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s19)"
                    editable           = "en_m6 and en_s19"
                    default            = "True"
                    title              = "Manager 6 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s20)"
                    editable           = "en_m6 and en_s20"
                    default            = "True"
                    title              = "Manager 6 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s21)"
                    editable           = "en_m6 and en_s21"
                    default            = "True"
                    title              = "Manager 6 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s22)"
                    editable           = "en_m6 and en_s22"
                    default            = "True"
                    title              = "Manager 6 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s23)"
                    editable           = "en_m6 and en_s23"
                    default            = "True"
                    title              = "Manager 6 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s24)"
                    editable           = "en_m6 and en_s24"
                    default            = "True"
                    title              = "Manager 6 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s25)"
                    editable           = "en_m6 and en_s25"
                    default            = "True"
                    title              = "Manager 6 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s26)"
                    editable           = "en_m6 and en_s26"
                    default            = "True"
                    title              = "Manager 6 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s27)"
                    editable           = "en_m6 and en_s27"
                    default            = "True"
                    title              = "Manager 6 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s28)"
                    editable           = "en_m6 and en_s28"
                    default            = "True"
                    title              = "Manager 6 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s29)"
                    editable           = "en_m6 and en_s29"
                    default            = "True"
                    title              = "Manager 6 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s30)"
                    editable           = "en_m6 and en_s30"
                    default            = "True"
                    title              = "Manager 6 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "m6_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m6 and en_s31)"
                    editable           = "en_m6 and en_s31"
                    default            = "True"
                    title              = "Manager 6 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 6 Connection Setting"
                    id                 = "M6_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m6_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s0)"
                    editable           = "en_m7 and en_s0"
                    default            = "True"
                    title              = "Manager 7 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s1)"
                    editable           = "en_m7 and en_s1"
                    default            = "True"
                    title              = "Manager 7 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s2)"
                    editable           = "en_m7 and en_s2"
                    default            = "True"
                    title              = "Manager 7 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s3)"
                    editable           = "en_m7 and en_s3"
                    default            = "True"
                    title              = "Manager 7 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s4)"
                    editable           = "en_m7 and en_s4"
                    default            = "True"
                    title              = "Manager 7 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s5)"
                    editable           = "en_m7 and en_s5"
                    default            = "True"
                    title              = "Manager 7 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s6)"
                    editable           = "en_m7 and en_s6"
                    default            = "True"
                    title              = "Manager 7 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s7)"
                    editable           = "en_m7 and en_s7"
                    default            = "True"
                    title              = "Manager 7 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s8)"
                    editable           = "en_m7 and en_s8"
                    default            = "True"
                    title              = "Manager 7 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s9)"
                    editable           = "en_m7 and en_s9"
                    default            = "True"
                    title              = "Manager 7 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s10)"
                    editable           = "en_m7 and en_s10"
                    default            = "True"
                    title              = "Manager 7 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s11)"
                    editable           = "en_m7 and en_s11"
                    default            = "True"
                    title              = "Manager 7 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s12)"
                    editable           = "en_m7 and en_s12"
                    default            = "True"
                    title              = "Manager 7 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s13)"
                    editable           = "en_m7 and en_s13"
                    default            = "True"
                    title              = "Manager 7 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s14)"
                    editable           = "en_m7 and en_s14"
                    default            = "True"
                    title              = "Manager 7 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s15)"
                    editable           = "en_m7 and en_s15"
                    default            = "True"
                    title              = "Manager 7 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s16)"
                    editable           = "en_m7 and en_s16"
                    default            = "True"
                    title              = "Manager 7 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s17)"
                    editable           = "en_m7 and en_s17"
                    default            = "True"
                    title              = "Manager 7 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s18)"
                    editable           = "en_m7 and en_s18"
                    default            = "True"
                    title              = "Manager 7 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s19)"
                    editable           = "en_m7 and en_s19"
                    default            = "True"
                    title              = "Manager 7 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s20)"
                    editable           = "en_m7 and en_s20"
                    default            = "True"
                    title              = "Manager 7 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s21)"
                    editable           = "en_m7 and en_s21"
                    default            = "True"
                    title              = "Manager 7 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s22)"
                    editable           = "en_m7 and en_s22"
                    default            = "True"
                    title              = "Manager 7 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s23)"
                    editable           = "en_m7 and en_s23"
                    default            = "True"
                    title              = "Manager 7 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s24)"
                    editable           = "en_m7 and en_s24"
                    default            = "True"
                    title              = "Manager 7 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s25)"
                    editable           = "en_m7 and en_s25"
                    default            = "True"
                    title              = "Manager 7 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s26)"
                    editable           = "en_m7 and en_s26"
                    default            = "True"
                    title              = "Manager 7 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s27)"
                    editable           = "en_m7 and en_s27"
                    default            = "True"
                    title              = "Manager 7 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s28)"
                    editable           = "en_m7 and en_s28"
                    default            = "True"
                    title              = "Manager 7 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s29)"
                    editable           = "en_m7 and en_s29"
                    default            = "True"
                    title              = "Manager 7 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s30)"
                    editable           = "en_m7 and en_s30"
                    default            = "True"
                    title              = "Manager 7 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "m7_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m7 and en_s31)"
                    editable           = "en_m7 and en_s31"
                    default            = "True"
                    title              = "Manager 7 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 7 Connection Setting"
                    id                 = "M7_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m7_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s0)"
                    editable           = "en_m8 and en_s0"
                    default            = "True"
                    title              = "Manager 8 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s1)"
                    editable           = "en_m8 and en_s1"
                    default            = "True"
                    title              = "Manager 8 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s2)"
                    editable           = "en_m8 and en_s2"
                    default            = "True"
                    title              = "Manager 8 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s3)"
                    editable           = "en_m8 and en_s3"
                    default            = "True"
                    title              = "Manager 8 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s4)"
                    editable           = "en_m8 and en_s4"
                    default            = "True"
                    title              = "Manager 8 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s5)"
                    editable           = "en_m8 and en_s5"
                    default            = "True"
                    title              = "Manager 8 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s6)"
                    editable           = "en_m8 and en_s6"
                    default            = "True"
                    title              = "Manager 8 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s7)"
                    editable           = "en_m8 and en_s7"
                    default            = "True"
                    title              = "Manager 8 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s8)"
                    editable           = "en_m8 and en_s8"
                    default            = "True"
                    title              = "Manager 8 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s9)"
                    editable           = "en_m8 and en_s9"
                    default            = "True"
                    title              = "Manager 8 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s10)"
                    editable           = "en_m8 and en_s10"
                    default            = "True"
                    title              = "Manager 8 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s11)"
                    editable           = "en_m8 and en_s11"
                    default            = "True"
                    title              = "Manager 8 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s12)"
                    editable           = "en_m8 and en_s12"
                    default            = "True"
                    title              = "Manager 8 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s13)"
                    editable           = "en_m8 and en_s13"
                    default            = "True"
                    title              = "Manager 8 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s14)"
                    editable           = "en_m8 and en_s14"
                    default            = "True"
                    title              = "Manager 8 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s15)"
                    editable           = "en_m8 and en_s15"
                    default            = "True"
                    title              = "Manager 8 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s16)"
                    editable           = "en_m8 and en_s16"
                    default            = "True"
                    title              = "Manager 8 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s17)"
                    editable           = "en_m8 and en_s17"
                    default            = "True"
                    title              = "Manager 8 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s18)"
                    editable           = "en_m8 and en_s18"
                    default            = "True"
                    title              = "Manager 8 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s19)"
                    editable           = "en_m8 and en_s19"
                    default            = "True"
                    title              = "Manager 8 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s20)"
                    editable           = "en_m8 and en_s20"
                    default            = "True"
                    title              = "Manager 8 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s21)"
                    editable           = "en_m8 and en_s21"
                    default            = "True"
                    title              = "Manager 8 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s22)"
                    editable           = "en_m8 and en_s22"
                    default            = "True"
                    title              = "Manager 8 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s23)"
                    editable           = "en_m8 and en_s23"
                    default            = "True"
                    title              = "Manager 8 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s24)"
                    editable           = "en_m8 and en_s24"
                    default            = "True"
                    title              = "Manager 8 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s25)"
                    editable           = "en_m8 and en_s25"
                    default            = "True"
                    title              = "Manager 8 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s26)"
                    editable           = "en_m8 and en_s26"
                    default            = "True"
                    title              = "Manager 8 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s27)"
                    editable           = "en_m8 and en_s27"
                    default            = "True"
                    title              = "Manager 8 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s28)"
                    editable           = "en_m8 and en_s28"
                    default            = "True"
                    title              = "Manager 8 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s29)"
                    editable           = "en_m8 and en_s29"
                    default            = "True"
                    title              = "Manager 8 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s30)"
                    editable           = "en_m8 and en_s30"
                    default            = "True"
                    title              = "Manager 8 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "m8_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m8 and en_s31)"
                    editable           = "en_m8 and en_s31"
                    default            = "True"
                    title              = "Manager 8 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 8 Connection Setting"
                    id                 = "M8_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m8_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s0)"
                    editable           = "en_m9 and en_s0"
                    default            = "True"
                    title              = "Manager 9 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s1)"
                    editable           = "en_m9 and en_s1"
                    default            = "True"
                    title              = "Manager 9 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s2)"
                    editable           = "en_m9 and en_s2"
                    default            = "True"
                    title              = "Manager 9 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s3)"
                    editable           = "en_m9 and en_s3"
                    default            = "True"
                    title              = "Manager 9 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s4)"
                    editable           = "en_m9 and en_s4"
                    default            = "True"
                    title              = "Manager 9 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s5)"
                    editable           = "en_m9 and en_s5"
                    default            = "True"
                    title              = "Manager 9 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s6)"
                    editable           = "en_m9 and en_s6"
                    default            = "True"
                    title              = "Manager 9 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s7)"
                    editable           = "en_m9 and en_s7"
                    default            = "True"
                    title              = "Manager 9 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s8)"
                    editable           = "en_m9 and en_s8"
                    default            = "True"
                    title              = "Manager 9 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s9)"
                    editable           = "en_m9 and en_s9"
                    default            = "True"
                    title              = "Manager 9 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s10)"
                    editable           = "en_m9 and en_s10"
                    default            = "True"
                    title              = "Manager 9 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s11)"
                    editable           = "en_m9 and en_s11"
                    default            = "True"
                    title              = "Manager 9 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s12)"
                    editable           = "en_m9 and en_s12"
                    default            = "True"
                    title              = "Manager 9 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s13)"
                    editable           = "en_m9 and en_s13"
                    default            = "True"
                    title              = "Manager 9 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s14)"
                    editable           = "en_m9 and en_s14"
                    default            = "True"
                    title              = "Manager 9 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s15)"
                    editable           = "en_m9 and en_s15"
                    default            = "True"
                    title              = "Manager 9 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s16)"
                    editable           = "en_m9 and en_s16"
                    default            = "True"
                    title              = "Manager 9 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s17)"
                    editable           = "en_m9 and en_s17"
                    default            = "True"
                    title              = "Manager 9 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s18)"
                    editable           = "en_m9 and en_s18"
                    default            = "True"
                    title              = "Manager 9 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s19)"
                    editable           = "en_m9 and en_s19"
                    default            = "True"
                    title              = "Manager 9 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s20)"
                    editable           = "en_m9 and en_s20"
                    default            = "True"
                    title              = "Manager 9 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s21)"
                    editable           = "en_m9 and en_s21"
                    default            = "True"
                    title              = "Manager 9 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s22)"
                    editable           = "en_m9 and en_s22"
                    default            = "True"
                    title              = "Manager 9 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s23)"
                    editable           = "en_m9 and en_s23"
                    default            = "True"
                    title              = "Manager 9 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s24)"
                    editable           = "en_m9 and en_s24"
                    default            = "True"
                    title              = "Manager 9 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s25)"
                    editable           = "en_m9 and en_s25"
                    default            = "True"
                    title              = "Manager 9 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s26)"
                    editable           = "en_m9 and en_s26"
                    default            = "True"
                    title              = "Manager 9 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s27)"
                    editable           = "en_m9 and en_s27"
                    default            = "True"
                    title              = "Manager 9 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s28)"
                    editable           = "en_m9 and en_s28"
                    default            = "True"
                    title              = "Manager 9 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s29)"
                    editable           = "en_m9 and en_s29"
                    default            = "True"
                    title              = "Manager 9 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s30)"
                    editable           = "en_m9 and en_s30"
                    default            = "True"
                    title              = "Manager 9 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "m9_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m9 and en_s31)"
                    editable           = "en_m9 and en_s31"
                    default            = "True"
                    title              = "Manager 9 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 9 Connection Setting"
                    id                 = "M9_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m9_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s0)"
                    editable           = "en_m10 and en_s0"
                    default            = "True"
                    title              = "Manager 10 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s1)"
                    editable           = "en_m10 and en_s1"
                    default            = "True"
                    title              = "Manager 10 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s2)"
                    editable           = "en_m10 and en_s2"
                    default            = "True"
                    title              = "Manager 10 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s3)"
                    editable           = "en_m10 and en_s3"
                    default            = "True"
                    title              = "Manager 10 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s4)"
                    editable           = "en_m10 and en_s4"
                    default            = "True"
                    title              = "Manager 10 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s5)"
                    editable           = "en_m10 and en_s5"
                    default            = "True"
                    title              = "Manager 10 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s6)"
                    editable           = "en_m10 and en_s6"
                    default            = "True"
                    title              = "Manager 10 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s7)"
                    editable           = "en_m10 and en_s7"
                    default            = "True"
                    title              = "Manager 10 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s8)"
                    editable           = "en_m10 and en_s8"
                    default            = "True"
                    title              = "Manager 10 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s9)"
                    editable           = "en_m10 and en_s9"
                    default            = "True"
                    title              = "Manager 10 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s10)"
                    editable           = "en_m10 and en_s10"
                    default            = "True"
                    title              = "Manager 10 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s11)"
                    editable           = "en_m10 and en_s11"
                    default            = "True"
                    title              = "Manager 10 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s12)"
                    editable           = "en_m10 and en_s12"
                    default            = "True"
                    title              = "Manager 10 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s13)"
                    editable           = "en_m10 and en_s13"
                    default            = "True"
                    title              = "Manager 10 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s14)"
                    editable           = "en_m10 and en_s14"
                    default            = "True"
                    title              = "Manager 10 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s15)"
                    editable           = "en_m10 and en_s15"
                    default            = "True"
                    title              = "Manager 10 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s16)"
                    editable           = "en_m10 and en_s16"
                    default            = "True"
                    title              = "Manager 10 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s17)"
                    editable           = "en_m10 and en_s17"
                    default            = "True"
                    title              = "Manager 10 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s18)"
                    editable           = "en_m10 and en_s18"
                    default            = "True"
                    title              = "Manager 10 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s19)"
                    editable           = "en_m10 and en_s19"
                    default            = "True"
                    title              = "Manager 10 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s20)"
                    editable           = "en_m10 and en_s20"
                    default            = "True"
                    title              = "Manager 10 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s21)"
                    editable           = "en_m10 and en_s21"
                    default            = "True"
                    title              = "Manager 10 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s22)"
                    editable           = "en_m10 and en_s22"
                    default            = "True"
                    title              = "Manager 10 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s23)"
                    editable           = "en_m10 and en_s23"
                    default            = "True"
                    title              = "Manager 10 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s24)"
                    editable           = "en_m10 and en_s24"
                    default            = "True"
                    title              = "Manager 10 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s25)"
                    editable           = "en_m10 and en_s25"
                    default            = "True"
                    title              = "Manager 10 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s26)"
                    editable           = "en_m10 and en_s26"
                    default            = "True"
                    title              = "Manager 10 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s27)"
                    editable           = "en_m10 and en_s27"
                    default            = "True"
                    title              = "Manager 10 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s28)"
                    editable           = "en_m10 and en_s28"
                    default            = "True"
                    title              = "Manager 10 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s29)"
                    editable           = "en_m10 and en_s29"
                    default            = "True"
                    title              = "Manager 10 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s30)"
                    editable           = "en_m10 and en_s30"
                    default            = "True"
                    title              = "Manager 10 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "m10_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m10 and en_s31)"
                    editable           = "en_m10 and en_s31"
                    default            = "True"
                    title              = "Manager 10 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 10 Connection Setting"
                    id                 = "M10_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m10_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s0)"
                    editable           = "en_m11 and en_s0"
                    default            = "True"
                    title              = "Manager 11 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s1)"
                    editable           = "en_m11 and en_s1"
                    default            = "True"
                    title              = "Manager 11 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s2)"
                    editable           = "en_m11 and en_s2"
                    default            = "True"
                    title              = "Manager 11 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s3)"
                    editable           = "en_m11 and en_s3"
                    default            = "True"
                    title              = "Manager 11 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s4)"
                    editable           = "en_m11 and en_s4"
                    default            = "True"
                    title              = "Manager 11 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s5)"
                    editable           = "en_m11 and en_s5"
                    default            = "True"
                    title              = "Manager 11 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s6)"
                    editable           = "en_m11 and en_s6"
                    default            = "True"
                    title              = "Manager 11 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s7)"
                    editable           = "en_m11 and en_s7"
                    default            = "True"
                    title              = "Manager 11 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s8)"
                    editable           = "en_m11 and en_s8"
                    default            = "True"
                    title              = "Manager 11 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s9)"
                    editable           = "en_m11 and en_s9"
                    default            = "True"
                    title              = "Manager 11 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s10)"
                    editable           = "en_m11 and en_s10"
                    default            = "True"
                    title              = "Manager 11 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s11)"
                    editable           = "en_m11 and en_s11"
                    default            = "True"
                    title              = "Manager 11 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s12)"
                    editable           = "en_m11 and en_s12"
                    default            = "True"
                    title              = "Manager 11 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s13)"
                    editable           = "en_m11 and en_s13"
                    default            = "True"
                    title              = "Manager 11 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s14)"
                    editable           = "en_m11 and en_s14"
                    default            = "True"
                    title              = "Manager 11 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s15)"
                    editable           = "en_m11 and en_s15"
                    default            = "True"
                    title              = "Manager 11 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s16)"
                    editable           = "en_m11 and en_s16"
                    default            = "True"
                    title              = "Manager 11 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s17)"
                    editable           = "en_m11 and en_s17"
                    default            = "True"
                    title              = "Manager 11 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s18)"
                    editable           = "en_m11 and en_s18"
                    default            = "True"
                    title              = "Manager 11 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s19)"
                    editable           = "en_m11 and en_s19"
                    default            = "True"
                    title              = "Manager 11 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s20)"
                    editable           = "en_m11 and en_s20"
                    default            = "True"
                    title              = "Manager 11 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s21)"
                    editable           = "en_m11 and en_s21"
                    default            = "True"
                    title              = "Manager 11 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s22)"
                    editable           = "en_m11 and en_s22"
                    default            = "True"
                    title              = "Manager 11 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s23)"
                    editable           = "en_m11 and en_s23"
                    default            = "True"
                    title              = "Manager 11 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s24)"
                    editable           = "en_m11 and en_s24"
                    default            = "True"
                    title              = "Manager 11 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s25)"
                    editable           = "en_m11 and en_s25"
                    default            = "True"
                    title              = "Manager 11 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s26)"
                    editable           = "en_m11 and en_s26"
                    default            = "True"
                    title              = "Manager 11 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s27)"
                    editable           = "en_m11 and en_s27"
                    default            = "True"
                    title              = "Manager 11 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s28)"
                    editable           = "en_m11 and en_s28"
                    default            = "True"
                    title              = "Manager 11 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s29)"
                    editable           = "en_m11 and en_s29"
                    default            = "True"
                    title              = "Manager 11 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s30)"
                    editable           = "en_m11 and en_s30"
                    default            = "True"
                    title              = "Manager 11 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "m11_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m11 and en_s31)"
                    editable           = "en_m11 and en_s31"
                    default            = "True"
                    title              = "Manager 11 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 11 Connection Setting"
                    id                 = "M11_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m11_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s0)"
                    editable           = "en_m12 and en_s0"
                    default            = "True"
                    title              = "Manager 12 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s1)"
                    editable           = "en_m12 and en_s1"
                    default            = "True"
                    title              = "Manager 12 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s2)"
                    editable           = "en_m12 and en_s2"
                    default            = "True"
                    title              = "Manager 12 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s3)"
                    editable           = "en_m12 and en_s3"
                    default            = "True"
                    title              = "Manager 12 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s4)"
                    editable           = "en_m12 and en_s4"
                    default            = "True"
                    title              = "Manager 12 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s5)"
                    editable           = "en_m12 and en_s5"
                    default            = "True"
                    title              = "Manager 12 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s6)"
                    editable           = "en_m12 and en_s6"
                    default            = "True"
                    title              = "Manager 12 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s7)"
                    editable           = "en_m12 and en_s7"
                    default            = "True"
                    title              = "Manager 12 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s8)"
                    editable           = "en_m12 and en_s8"
                    default            = "True"
                    title              = "Manager 12 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s9)"
                    editable           = "en_m12 and en_s9"
                    default            = "True"
                    title              = "Manager 12 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s10)"
                    editable           = "en_m12 and en_s10"
                    default            = "True"
                    title              = "Manager 12 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s11)"
                    editable           = "en_m12 and en_s11"
                    default            = "True"
                    title              = "Manager 12 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s12)"
                    editable           = "en_m12 and en_s12"
                    default            = "True"
                    title              = "Manager 12 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s13)"
                    editable           = "en_m12 and en_s13"
                    default            = "True"
                    title              = "Manager 12 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s14)"
                    editable           = "en_m12 and en_s14"
                    default            = "True"
                    title              = "Manager 12 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s15)"
                    editable           = "en_m12 and en_s15"
                    default            = "True"
                    title              = "Manager 12 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s16)"
                    editable           = "en_m12 and en_s16"
                    default            = "True"
                    title              = "Manager 12 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s17)"
                    editable           = "en_m12 and en_s17"
                    default            = "True"
                    title              = "Manager 12 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s18)"
                    editable           = "en_m12 and en_s18"
                    default            = "True"
                    title              = "Manager 12 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s19)"
                    editable           = "en_m12 and en_s19"
                    default            = "True"
                    title              = "Manager 12 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s20)"
                    editable           = "en_m12 and en_s20"
                    default            = "True"
                    title              = "Manager 12 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s21)"
                    editable           = "en_m12 and en_s21"
                    default            = "True"
                    title              = "Manager 12 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s22)"
                    editable           = "en_m12 and en_s22"
                    default            = "True"
                    title              = "Manager 12 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s23)"
                    editable           = "en_m12 and en_s23"
                    default            = "True"
                    title              = "Manager 12 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s24)"
                    editable           = "en_m12 and en_s24"
                    default            = "True"
                    title              = "Manager 12 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s25)"
                    editable           = "en_m12 and en_s25"
                    default            = "True"
                    title              = "Manager 12 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s26)"
                    editable           = "en_m12 and en_s26"
                    default            = "True"
                    title              = "Manager 12 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s27)"
                    editable           = "en_m12 and en_s27"
                    default            = "True"
                    title              = "Manager 12 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s28)"
                    editable           = "en_m12 and en_s28"
                    default            = "True"
                    title              = "Manager 12 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s29)"
                    editable           = "en_m12 and en_s29"
                    default            = "True"
                    title              = "Manager 12 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s30)"
                    editable           = "en_m12 and en_s30"
                    default            = "True"
                    title              = "Manager 12 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "m12_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m12 and en_s31)"
                    editable           = "en_m12 and en_s31"
                    default            = "True"
                    title              = "Manager 12 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 12 Connection Setting"
                    id                 = "M12_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m12_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s0)"
                    editable           = "en_m13 and en_s0"
                    default            = "True"
                    title              = "Manager 13 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s1)"
                    editable           = "en_m13 and en_s1"
                    default            = "True"
                    title              = "Manager 13 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s2)"
                    editable           = "en_m13 and en_s2"
                    default            = "True"
                    title              = "Manager 13 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s3)"
                    editable           = "en_m13 and en_s3"
                    default            = "True"
                    title              = "Manager 13 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s4)"
                    editable           = "en_m13 and en_s4"
                    default            = "True"
                    title              = "Manager 13 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s5)"
                    editable           = "en_m13 and en_s5"
                    default            = "True"
                    title              = "Manager 13 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s6)"
                    editable           = "en_m13 and en_s6"
                    default            = "True"
                    title              = "Manager 13 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s7)"
                    editable           = "en_m13 and en_s7"
                    default            = "True"
                    title              = "Manager 13 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s8)"
                    editable           = "en_m13 and en_s8"
                    default            = "True"
                    title              = "Manager 13 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s9)"
                    editable           = "en_m13 and en_s9"
                    default            = "True"
                    title              = "Manager 13 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s10)"
                    editable           = "en_m13 and en_s10"
                    default            = "True"
                    title              = "Manager 13 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s11)"
                    editable           = "en_m13 and en_s11"
                    default            = "True"
                    title              = "Manager 13 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s12)"
                    editable           = "en_m13 and en_s12"
                    default            = "True"
                    title              = "Manager 13 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s13)"
                    editable           = "en_m13 and en_s13"
                    default            = "True"
                    title              = "Manager 13 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s14)"
                    editable           = "en_m13 and en_s14"
                    default            = "True"
                    title              = "Manager 13 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s15)"
                    editable           = "en_m13 and en_s15"
                    default            = "True"
                    title              = "Manager 13 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s16)"
                    editable           = "en_m13 and en_s16"
                    default            = "True"
                    title              = "Manager 13 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s17)"
                    editable           = "en_m13 and en_s17"
                    default            = "True"
                    title              = "Manager 13 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s18)"
                    editable           = "en_m13 and en_s18"
                    default            = "True"
                    title              = "Manager 13 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s19)"
                    editable           = "en_m13 and en_s19"
                    default            = "True"
                    title              = "Manager 13 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s20)"
                    editable           = "en_m13 and en_s20"
                    default            = "True"
                    title              = "Manager 13 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s21)"
                    editable           = "en_m13 and en_s21"
                    default            = "True"
                    title              = "Manager 13 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s22)"
                    editable           = "en_m13 and en_s22"
                    default            = "True"
                    title              = "Manager 13 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s23)"
                    editable           = "en_m13 and en_s23"
                    default            = "True"
                    title              = "Manager 13 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s24)"
                    editable           = "en_m13 and en_s24"
                    default            = "True"
                    title              = "Manager 13 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s25)"
                    editable           = "en_m13 and en_s25"
                    default            = "True"
                    title              = "Manager 13 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s26)"
                    editable           = "en_m13 and en_s26"
                    default            = "True"
                    title              = "Manager 13 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s27)"
                    editable           = "en_m13 and en_s27"
                    default            = "True"
                    title              = "Manager 13 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s28)"
                    editable           = "en_m13 and en_s28"
                    default            = "True"
                    title              = "Manager 13 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s29)"
                    editable           = "en_m13 and en_s29"
                    default            = "True"
                    title              = "Manager 13 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s30)"
                    editable           = "en_m13 and en_s30"
                    default            = "True"
                    title              = "Manager 13 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "m13_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m13 and en_s31)"
                    editable           = "en_m13 and en_s31"
                    default            = "True"
                    title              = "Manager 13 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 13 Connection Setting"
                    id                 = "M13_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m13_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s0)"
                    editable           = "en_m14 and en_s0"
                    default            = "True"
                    title              = "Manager 14 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s1)"
                    editable           = "en_m14 and en_s1"
                    default            = "True"
                    title              = "Manager 14 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s2)"
                    editable           = "en_m14 and en_s2"
                    default            = "True"
                    title              = "Manager 14 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s3)"
                    editable           = "en_m14 and en_s3"
                    default            = "True"
                    title              = "Manager 14 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s4)"
                    editable           = "en_m14 and en_s4"
                    default            = "True"
                    title              = "Manager 14 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s5)"
                    editable           = "en_m14 and en_s5"
                    default            = "True"
                    title              = "Manager 14 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s6)"
                    editable           = "en_m14 and en_s6"
                    default            = "True"
                    title              = "Manager 14 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s7)"
                    editable           = "en_m14 and en_s7"
                    default            = "True"
                    title              = "Manager 14 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s8)"
                    editable           = "en_m14 and en_s8"
                    default            = "True"
                    title              = "Manager 14 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s9)"
                    editable           = "en_m14 and en_s9"
                    default            = "True"
                    title              = "Manager 14 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s10)"
                    editable           = "en_m14 and en_s10"
                    default            = "True"
                    title              = "Manager 14 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s11)"
                    editable           = "en_m14 and en_s11"
                    default            = "True"
                    title              = "Manager 14 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s12)"
                    editable           = "en_m14 and en_s12"
                    default            = "True"
                    title              = "Manager 14 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s13)"
                    editable           = "en_m14 and en_s13"
                    default            = "True"
                    title              = "Manager 14 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s14)"
                    editable           = "en_m14 and en_s14"
                    default            = "True"
                    title              = "Manager 14 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s15)"
                    editable           = "en_m14 and en_s15"
                    default            = "True"
                    title              = "Manager 14 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s16)"
                    editable           = "en_m14 and en_s16"
                    default            = "True"
                    title              = "Manager 14 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s17)"
                    editable           = "en_m14 and en_s17"
                    default            = "True"
                    title              = "Manager 14 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s18)"
                    editable           = "en_m14 and en_s18"
                    default            = "True"
                    title              = "Manager 14 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s19)"
                    editable           = "en_m14 and en_s19"
                    default            = "True"
                    title              = "Manager 14 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s20)"
                    editable           = "en_m14 and en_s20"
                    default            = "True"
                    title              = "Manager 14 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s21)"
                    editable           = "en_m14 and en_s21"
                    default            = "True"
                    title              = "Manager 14 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s22)"
                    editable           = "en_m14 and en_s22"
                    default            = "True"
                    title              = "Manager 14 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s23)"
                    editable           = "en_m14 and en_s23"
                    default            = "True"
                    title              = "Manager 14 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s24)"
                    editable           = "en_m14 and en_s24"
                    default            = "True"
                    title              = "Manager 14 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s25)"
                    editable           = "en_m14 and en_s25"
                    default            = "True"
                    title              = "Manager 14 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s26)"
                    editable           = "en_m14 and en_s26"
                    default            = "True"
                    title              = "Manager 14 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s27)"
                    editable           = "en_m14 and en_s27"
                    default            = "True"
                    title              = "Manager 14 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s28)"
                    editable           = "en_m14 and en_s28"
                    default            = "True"
                    title              = "Manager 14 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s29)"
                    editable           = "en_m14 and en_s29"
                    default            = "True"
                    title              = "Manager 14 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s30)"
                    editable           = "en_m14 and en_s30"
                    default            = "True"
                    title              = "Manager 14 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "m14_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m14 and en_s31)"
                    editable           = "en_m14 and en_s31"
                    default            = "True"
                    title              = "Manager 14 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 14 Connection Setting"
                    id                 = "M14_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m14_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s0)"
                    editable           = "en_m15 and en_s0"
                    default            = "True"
                    title              = "Manager 15 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s1)"
                    editable           = "en_m15 and en_s1"
                    default            = "True"
                    title              = "Manager 15 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s2)"
                    editable           = "en_m15 and en_s2"
                    default            = "True"
                    title              = "Manager 15 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s3)"
                    editable           = "en_m15 and en_s3"
                    default            = "True"
                    title              = "Manager 15 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s4)"
                    editable           = "en_m15 and en_s4"
                    default            = "True"
                    title              = "Manager 15 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s5)"
                    editable           = "en_m15 and en_s5"
                    default            = "True"
                    title              = "Manager 15 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s6)"
                    editable           = "en_m15 and en_s6"
                    default            = "True"
                    title              = "Manager 15 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s7)"
                    editable           = "en_m15 and en_s7"
                    default            = "True"
                    title              = "Manager 15 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s8)"
                    editable           = "en_m15 and en_s8"
                    default            = "True"
                    title              = "Manager 15 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s9)"
                    editable           = "en_m15 and en_s9"
                    default            = "True"
                    title              = "Manager 15 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s10)"
                    editable           = "en_m15 and en_s10"
                    default            = "True"
                    title              = "Manager 15 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s11)"
                    editable           = "en_m15 and en_s11"
                    default            = "True"
                    title              = "Manager 15 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s12)"
                    editable           = "en_m15 and en_s12"
                    default            = "True"
                    title              = "Manager 15 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s13)"
                    editable           = "en_m15 and en_s13"
                    default            = "True"
                    title              = "Manager 15 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s14)"
                    editable           = "en_m15 and en_s14"
                    default            = "True"
                    title              = "Manager 15 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s15)"
                    editable           = "en_m15 and en_s15"
                    default            = "True"
                    title              = "Manager 15 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s16)"
                    editable           = "en_m15 and en_s16"
                    default            = "True"
                    title              = "Manager 15 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s17)"
                    editable           = "en_m15 and en_s17"
                    default            = "True"
                    title              = "Manager 15 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s18)"
                    editable           = "en_m15 and en_s18"
                    default            = "True"
                    title              = "Manager 15 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s19)"
                    editable           = "en_m15 and en_s19"
                    default            = "True"
                    title              = "Manager 15 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s20)"
                    editable           = "en_m15 and en_s20"
                    default            = "True"
                    title              = "Manager 15 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s21)"
                    editable           = "en_m15 and en_s21"
                    default            = "True"
                    title              = "Manager 15 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s22)"
                    editable           = "en_m15 and en_s22"
                    default            = "True"
                    title              = "Manager 15 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s23)"
                    editable           = "en_m15 and en_s23"
                    default            = "True"
                    title              = "Manager 15 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s24)"
                    editable           = "en_m15 and en_s24"
                    default            = "True"
                    title              = "Manager 15 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s25)"
                    editable           = "en_m15 and en_s25"
                    default            = "True"
                    title              = "Manager 15 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s26)"
                    editable           = "en_m15 and en_s26"
                    default            = "True"
                    title              = "Manager 15 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s27)"
                    editable           = "en_m15 and en_s27"
                    default            = "True"
                    title              = "Manager 15 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s28)"
                    editable           = "en_m15 and en_s28"
                    default            = "True"
                    title              = "Manager 15 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s29)"
                    editable           = "en_m15 and en_s29"
                    default            = "True"
                    title              = "Manager 15 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s30)"
                    editable           = "en_m15 and en_s30"
                    default            = "True"
                    title              = "Manager 15 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "m15_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m15 and en_s31)"
                    editable           = "en_m15 and en_s31"
                    default            = "True"
                    title              = "Manager 15 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 15 Connection Setting"
                    id                 = "M15_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m15_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s0)"
                    editable           = "en_m16 and en_s0"
                    default            = "True"
                    title              = "Manager 16 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s1)"
                    editable           = "en_m16 and en_s1"
                    default            = "True"
                    title              = "Manager 16 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s2)"
                    editable           = "en_m16 and en_s2"
                    default            = "True"
                    title              = "Manager 16 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s3)"
                    editable           = "en_m16 and en_s3"
                    default            = "True"
                    title              = "Manager 16 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s4)"
                    editable           = "en_m16 and en_s4"
                    default            = "True"
                    title              = "Manager 16 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s5)"
                    editable           = "en_m16 and en_s5"
                    default            = "True"
                    title              = "Manager 16 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s6)"
                    editable           = "en_m16 and en_s6"
                    default            = "True"
                    title              = "Manager 16 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s7)"
                    editable           = "en_m16 and en_s7"
                    default            = "True"
                    title              = "Manager 16 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s8)"
                    editable           = "en_m16 and en_s8"
                    default            = "True"
                    title              = "Manager 16 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s9)"
                    editable           = "en_m16 and en_s9"
                    default            = "True"
                    title              = "Manager 16 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s10)"
                    editable           = "en_m16 and en_s10"
                    default            = "True"
                    title              = "Manager 16 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s11)"
                    editable           = "en_m16 and en_s11"
                    default            = "True"
                    title              = "Manager 16 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s12)"
                    editable           = "en_m16 and en_s12"
                    default            = "True"
                    title              = "Manager 16 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s13)"
                    editable           = "en_m16 and en_s13"
                    default            = "True"
                    title              = "Manager 16 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s14)"
                    editable           = "en_m16 and en_s14"
                    default            = "True"
                    title              = "Manager 16 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s15)"
                    editable           = "en_m16 and en_s15"
                    default            = "True"
                    title              = "Manager 16 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s16)"
                    editable           = "en_m16 and en_s16"
                    default            = "True"
                    title              = "Manager 16 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s17)"
                    editable           = "en_m16 and en_s17"
                    default            = "True"
                    title              = "Manager 16 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s18)"
                    editable           = "en_m16 and en_s18"
                    default            = "True"
                    title              = "Manager 16 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s19)"
                    editable           = "en_m16 and en_s19"
                    default            = "True"
                    title              = "Manager 16 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s20)"
                    editable           = "en_m16 and en_s20"
                    default            = "True"
                    title              = "Manager 16 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s21)"
                    editable           = "en_m16 and en_s21"
                    default            = "True"
                    title              = "Manager 16 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s22)"
                    editable           = "en_m16 and en_s22"
                    default            = "True"
                    title              = "Manager 16 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s23)"
                    editable           = "en_m16 and en_s23"
                    default            = "True"
                    title              = "Manager 16 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s24)"
                    editable           = "en_m16 and en_s24"
                    default            = "True"
                    title              = "Manager 16 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s25)"
                    editable           = "en_m16 and en_s25"
                    default            = "True"
                    title              = "Manager 16 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s26)"
                    editable           = "en_m16 and en_s26"
                    default            = "True"
                    title              = "Manager 16 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s27)"
                    editable           = "en_m16 and en_s27"
                    default            = "True"
                    title              = "Manager 16 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s28)"
                    editable           = "en_m16 and en_s28"
                    default            = "True"
                    title              = "Manager 16 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s29)"
                    editable           = "en_m16 and en_s29"
                    default            = "True"
                    title              = "Manager 16 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s30)"
                    editable           = "en_m16 and en_s30"
                    default            = "True"
                    title              = "Manager 16 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "m16_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m16 and en_s31)"
                    editable           = "en_m16 and en_s31"
                    default            = "True"
                    title              = "Manager 16 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 16 Connection Setting"
                    id                 = "M16_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m16_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s0)"
                    editable           = "en_m17 and en_s0"
                    default            = "True"
                    title              = "Manager 17 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s1)"
                    editable           = "en_m17 and en_s1"
                    default            = "True"
                    title              = "Manager 17 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s2)"
                    editable           = "en_m17 and en_s2"
                    default            = "True"
                    title              = "Manager 17 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s3)"
                    editable           = "en_m17 and en_s3"
                    default            = "True"
                    title              = "Manager 17 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s4)"
                    editable           = "en_m17 and en_s4"
                    default            = "True"
                    title              = "Manager 17 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s5)"
                    editable           = "en_m17 and en_s5"
                    default            = "True"
                    title              = "Manager 17 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s6)"
                    editable           = "en_m17 and en_s6"
                    default            = "True"
                    title              = "Manager 17 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s7)"
                    editable           = "en_m17 and en_s7"
                    default            = "True"
                    title              = "Manager 17 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s8)"
                    editable           = "en_m17 and en_s8"
                    default            = "True"
                    title              = "Manager 17 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s9)"
                    editable           = "en_m17 and en_s9"
                    default            = "True"
                    title              = "Manager 17 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s10)"
                    editable           = "en_m17 and en_s10"
                    default            = "True"
                    title              = "Manager 17 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s11)"
                    editable           = "en_m17 and en_s11"
                    default            = "True"
                    title              = "Manager 17 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s12)"
                    editable           = "en_m17 and en_s12"
                    default            = "True"
                    title              = "Manager 17 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s13)"
                    editable           = "en_m17 and en_s13"
                    default            = "True"
                    title              = "Manager 17 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s14)"
                    editable           = "en_m17 and en_s14"
                    default            = "True"
                    title              = "Manager 17 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s15)"
                    editable           = "en_m17 and en_s15"
                    default            = "True"
                    title              = "Manager 17 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s16)"
                    editable           = "en_m17 and en_s16"
                    default            = "True"
                    title              = "Manager 17 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s17)"
                    editable           = "en_m17 and en_s17"
                    default            = "True"
                    title              = "Manager 17 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s18)"
                    editable           = "en_m17 and en_s18"
                    default            = "True"
                    title              = "Manager 17 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s19)"
                    editable           = "en_m17 and en_s19"
                    default            = "True"
                    title              = "Manager 17 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s20)"
                    editable           = "en_m17 and en_s20"
                    default            = "True"
                    title              = "Manager 17 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s21)"
                    editable           = "en_m17 and en_s21"
                    default            = "True"
                    title              = "Manager 17 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s22)"
                    editable           = "en_m17 and en_s22"
                    default            = "True"
                    title              = "Manager 17 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s23)"
                    editable           = "en_m17 and en_s23"
                    default            = "True"
                    title              = "Manager 17 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s24)"
                    editable           = "en_m17 and en_s24"
                    default            = "True"
                    title              = "Manager 17 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s25)"
                    editable           = "en_m17 and en_s25"
                    default            = "True"
                    title              = "Manager 17 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s26)"
                    editable           = "en_m17 and en_s26"
                    default            = "True"
                    title              = "Manager 17 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s27)"
                    editable           = "en_m17 and en_s27"
                    default            = "True"
                    title              = "Manager 17 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s28)"
                    editable           = "en_m17 and en_s28"
                    default            = "True"
                    title              = "Manager 17 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s29)"
                    editable           = "en_m17 and en_s29"
                    default            = "True"
                    title              = "Manager 17 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s30)"
                    editable           = "en_m17 and en_s30"
                    default            = "True"
                    title              = "Manager 17 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "m17_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m17 and en_s31)"
                    editable           = "en_m17 and en_s31"
                    default            = "True"
                    title              = "Manager 17 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 17 Connection Setting"
                    id                 = "M17_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m17_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s0)"
                    editable           = "en_m18 and en_s0"
                    default            = "True"
                    title              = "Manager 18 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s1)"
                    editable           = "en_m18 and en_s1"
                    default            = "True"
                    title              = "Manager 18 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s2)"
                    editable           = "en_m18 and en_s2"
                    default            = "True"
                    title              = "Manager 18 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s3)"
                    editable           = "en_m18 and en_s3"
                    default            = "True"
                    title              = "Manager 18 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s4)"
                    editable           = "en_m18 and en_s4"
                    default            = "True"
                    title              = "Manager 18 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s5)"
                    editable           = "en_m18 and en_s5"
                    default            = "True"
                    title              = "Manager 18 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s6)"
                    editable           = "en_m18 and en_s6"
                    default            = "True"
                    title              = "Manager 18 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s7)"
                    editable           = "en_m18 and en_s7"
                    default            = "True"
                    title              = "Manager 18 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s8)"
                    editable           = "en_m18 and en_s8"
                    default            = "True"
                    title              = "Manager 18 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s9)"
                    editable           = "en_m18 and en_s9"
                    default            = "True"
                    title              = "Manager 18 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s10)"
                    editable           = "en_m18 and en_s10"
                    default            = "True"
                    title              = "Manager 18 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s11)"
                    editable           = "en_m18 and en_s11"
                    default            = "True"
                    title              = "Manager 18 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s12)"
                    editable           = "en_m18 and en_s12"
                    default            = "True"
                    title              = "Manager 18 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s13)"
                    editable           = "en_m18 and en_s13"
                    default            = "True"
                    title              = "Manager 18 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s14)"
                    editable           = "en_m18 and en_s14"
                    default            = "True"
                    title              = "Manager 18 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s15)"
                    editable           = "en_m18 and en_s15"
                    default            = "True"
                    title              = "Manager 18 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s16)"
                    editable           = "en_m18 and en_s16"
                    default            = "True"
                    title              = "Manager 18 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s17)"
                    editable           = "en_m18 and en_s17"
                    default            = "True"
                    title              = "Manager 18 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s18)"
                    editable           = "en_m18 and en_s18"
                    default            = "True"
                    title              = "Manager 18 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s19)"
                    editable           = "en_m18 and en_s19"
                    default            = "True"
                    title              = "Manager 18 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s20)"
                    editable           = "en_m18 and en_s20"
                    default            = "True"
                    title              = "Manager 18 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s21)"
                    editable           = "en_m18 and en_s21"
                    default            = "True"
                    title              = "Manager 18 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s22)"
                    editable           = "en_m18 and en_s22"
                    default            = "True"
                    title              = "Manager 18 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s23)"
                    editable           = "en_m18 and en_s23"
                    default            = "True"
                    title              = "Manager 18 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s24)"
                    editable           = "en_m18 and en_s24"
                    default            = "True"
                    title              = "Manager 18 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s25)"
                    editable           = "en_m18 and en_s25"
                    default            = "True"
                    title              = "Manager 18 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s26)"
                    editable           = "en_m18 and en_s26"
                    default            = "True"
                    title              = "Manager 18 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s27)"
                    editable           = "en_m18 and en_s27"
                    default            = "True"
                    title              = "Manager 18 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s28)"
                    editable           = "en_m18 and en_s28"
                    default            = "True"
                    title              = "Manager 18 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s29)"
                    editable           = "en_m18 and en_s29"
                    default            = "True"
                    title              = "Manager 18 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s30)"
                    editable           = "en_m18 and en_s30"
                    default            = "True"
                    title              = "Manager 18 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "m18_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m18 and en_s31)"
                    editable           = "en_m18 and en_s31"
                    default            = "True"
                    title              = "Manager 18 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 18 Connection Setting"
                    id                 = "M18_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m18_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s0)"
                    editable           = "en_m19 and en_s0"
                    default            = "True"
                    title              = "Manager 19 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s1)"
                    editable           = "en_m19 and en_s1"
                    default            = "True"
                    title              = "Manager 19 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s2)"
                    editable           = "en_m19 and en_s2"
                    default            = "True"
                    title              = "Manager 19 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s3)"
                    editable           = "en_m19 and en_s3"
                    default            = "True"
                    title              = "Manager 19 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s4)"
                    editable           = "en_m19 and en_s4"
                    default            = "True"
                    title              = "Manager 19 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s5)"
                    editable           = "en_m19 and en_s5"
                    default            = "True"
                    title              = "Manager 19 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s6)"
                    editable           = "en_m19 and en_s6"
                    default            = "True"
                    title              = "Manager 19 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s7)"
                    editable           = "en_m19 and en_s7"
                    default            = "True"
                    title              = "Manager 19 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s8)"
                    editable           = "en_m19 and en_s8"
                    default            = "True"
                    title              = "Manager 19 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s9)"
                    editable           = "en_m19 and en_s9"
                    default            = "True"
                    title              = "Manager 19 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s10)"
                    editable           = "en_m19 and en_s10"
                    default            = "True"
                    title              = "Manager 19 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s11)"
                    editable           = "en_m19 and en_s11"
                    default            = "True"
                    title              = "Manager 19 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s12)"
                    editable           = "en_m19 and en_s12"
                    default            = "True"
                    title              = "Manager 19 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s13)"
                    editable           = "en_m19 and en_s13"
                    default            = "True"
                    title              = "Manager 19 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s14)"
                    editable           = "en_m19 and en_s14"
                    default            = "True"
                    title              = "Manager 19 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s15)"
                    editable           = "en_m19 and en_s15"
                    default            = "True"
                    title              = "Manager 19 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s16)"
                    editable           = "en_m19 and en_s16"
                    default            = "True"
                    title              = "Manager 19 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s17)"
                    editable           = "en_m19 and en_s17"
                    default            = "True"
                    title              = "Manager 19 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s18)"
                    editable           = "en_m19 and en_s18"
                    default            = "True"
                    title              = "Manager 19 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s19)"
                    editable           = "en_m19 and en_s19"
                    default            = "True"
                    title              = "Manager 19 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s20)"
                    editable           = "en_m19 and en_s20"
                    default            = "True"
                    title              = "Manager 19 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s21)"
                    editable           = "en_m19 and en_s21"
                    default            = "True"
                    title              = "Manager 19 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s22)"
                    editable           = "en_m19 and en_s22"
                    default            = "True"
                    title              = "Manager 19 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s23)"
                    editable           = "en_m19 and en_s23"
                    default            = "True"
                    title              = "Manager 19 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s24)"
                    editable           = "en_m19 and en_s24"
                    default            = "True"
                    title              = "Manager 19 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s25)"
                    editable           = "en_m19 and en_s25"
                    default            = "True"
                    title              = "Manager 19 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s26)"
                    editable           = "en_m19 and en_s26"
                    default            = "True"
                    title              = "Manager 19 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s27)"
                    editable           = "en_m19 and en_s27"
                    default            = "True"
                    title              = "Manager 19 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s28)"
                    editable           = "en_m19 and en_s28"
                    default            = "True"
                    title              = "Manager 19 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s29)"
                    editable           = "en_m19 and en_s29"
                    default            = "True"
                    title              = "Manager 19 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s30)"
                    editable           = "en_m19 and en_s30"
                    default            = "True"
                    title              = "Manager 19 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "m19_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m19 and en_s31)"
                    editable           = "en_m19 and en_s31"
                    default            = "True"
                    title              = "Manager 19 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 19 Connection Setting"
                    id                 = "M19_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m19_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s0)"
                    editable           = "en_m20 and en_s0"
                    default            = "True"
                    title              = "Manager 20 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s1)"
                    editable           = "en_m20 and en_s1"
                    default            = "True"
                    title              = "Manager 20 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s2)"
                    editable           = "en_m20 and en_s2"
                    default            = "True"
                    title              = "Manager 20 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s3)"
                    editable           = "en_m20 and en_s3"
                    default            = "True"
                    title              = "Manager 20 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s4)"
                    editable           = "en_m20 and en_s4"
                    default            = "True"
                    title              = "Manager 20 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s5)"
                    editable           = "en_m20 and en_s5"
                    default            = "True"
                    title              = "Manager 20 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s6)"
                    editable           = "en_m20 and en_s6"
                    default            = "True"
                    title              = "Manager 20 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s7)"
                    editable           = "en_m20 and en_s7"
                    default            = "True"
                    title              = "Manager 20 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s8)"
                    editable           = "en_m20 and en_s8"
                    default            = "True"
                    title              = "Manager 20 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s9)"
                    editable           = "en_m20 and en_s9"
                    default            = "True"
                    title              = "Manager 20 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s10)"
                    editable           = "en_m20 and en_s10"
                    default            = "True"
                    title              = "Manager 20 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s11)"
                    editable           = "en_m20 and en_s11"
                    default            = "True"
                    title              = "Manager 20 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s12)"
                    editable           = "en_m20 and en_s12"
                    default            = "True"
                    title              = "Manager 20 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s13)"
                    editable           = "en_m20 and en_s13"
                    default            = "True"
                    title              = "Manager 20 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s14)"
                    editable           = "en_m20 and en_s14"
                    default            = "True"
                    title              = "Manager 20 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s15)"
                    editable           = "en_m20 and en_s15"
                    default            = "True"
                    title              = "Manager 20 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s16)"
                    editable           = "en_m20 and en_s16"
                    default            = "True"
                    title              = "Manager 20 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s17)"
                    editable           = "en_m20 and en_s17"
                    default            = "True"
                    title              = "Manager 20 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s18)"
                    editable           = "en_m20 and en_s18"
                    default            = "True"
                    title              = "Manager 20 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s19)"
                    editable           = "en_m20 and en_s19"
                    default            = "True"
                    title              = "Manager 20 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s20)"
                    editable           = "en_m20 and en_s20"
                    default            = "True"
                    title              = "Manager 20 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s21)"
                    editable           = "en_m20 and en_s21"
                    default            = "True"
                    title              = "Manager 20 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s22)"
                    editable           = "en_m20 and en_s22"
                    default            = "True"
                    title              = "Manager 20 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s23)"
                    editable           = "en_m20 and en_s23"
                    default            = "True"
                    title              = "Manager 20 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s24)"
                    editable           = "en_m20 and en_s24"
                    default            = "True"
                    title              = "Manager 20 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s25)"
                    editable           = "en_m20 and en_s25"
                    default            = "True"
                    title              = "Manager 20 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s26)"
                    editable           = "en_m20 and en_s26"
                    default            = "True"
                    title              = "Manager 20 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s27)"
                    editable           = "en_m20 and en_s27"
                    default            = "True"
                    title              = "Manager 20 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s28)"
                    editable           = "en_m20 and en_s28"
                    default            = "True"
                    title              = "Manager 20 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s29)"
                    editable           = "en_m20 and en_s29"
                    default            = "True"
                    title              = "Manager 20 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s30)"
                    editable           = "en_m20 and en_s30"
                    default            = "True"
                    title              = "Manager 20 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "m20_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m20 and en_s31)"
                    editable           = "en_m20 and en_s31"
                    default            = "True"
                    title              = "Manager 20 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 20 Connection Setting"
                    id                 = "M20_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m20_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s0)"
                    editable           = "en_m21 and en_s0"
                    default            = "True"
                    title              = "Manager 21 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s1)"
                    editable           = "en_m21 and en_s1"
                    default            = "True"
                    title              = "Manager 21 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s2)"
                    editable           = "en_m21 and en_s2"
                    default            = "True"
                    title              = "Manager 21 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s3)"
                    editable           = "en_m21 and en_s3"
                    default            = "True"
                    title              = "Manager 21 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s4)"
                    editable           = "en_m21 and en_s4"
                    default            = "True"
                    title              = "Manager 21 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s5)"
                    editable           = "en_m21 and en_s5"
                    default            = "True"
                    title              = "Manager 21 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s6)"
                    editable           = "en_m21 and en_s6"
                    default            = "True"
                    title              = "Manager 21 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s7)"
                    editable           = "en_m21 and en_s7"
                    default            = "True"
                    title              = "Manager 21 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s8)"
                    editable           = "en_m21 and en_s8"
                    default            = "True"
                    title              = "Manager 21 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s9)"
                    editable           = "en_m21 and en_s9"
                    default            = "True"
                    title              = "Manager 21 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s10)"
                    editable           = "en_m21 and en_s10"
                    default            = "True"
                    title              = "Manager 21 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s11)"
                    editable           = "en_m21 and en_s11"
                    default            = "True"
                    title              = "Manager 21 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s12)"
                    editable           = "en_m21 and en_s12"
                    default            = "True"
                    title              = "Manager 21 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s13)"
                    editable           = "en_m21 and en_s13"
                    default            = "True"
                    title              = "Manager 21 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s14)"
                    editable           = "en_m21 and en_s14"
                    default            = "True"
                    title              = "Manager 21 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s15)"
                    editable           = "en_m21 and en_s15"
                    default            = "True"
                    title              = "Manager 21 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s16)"
                    editable           = "en_m21 and en_s16"
                    default            = "True"
                    title              = "Manager 21 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s17)"
                    editable           = "en_m21 and en_s17"
                    default            = "True"
                    title              = "Manager 21 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s18)"
                    editable           = "en_m21 and en_s18"
                    default            = "True"
                    title              = "Manager 21 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s19)"
                    editable           = "en_m21 and en_s19"
                    default            = "True"
                    title              = "Manager 21 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s20)"
                    editable           = "en_m21 and en_s20"
                    default            = "True"
                    title              = "Manager 21 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s21)"
                    editable           = "en_m21 and en_s21"
                    default            = "True"
                    title              = "Manager 21 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s22)"
                    editable           = "en_m21 and en_s22"
                    default            = "True"
                    title              = "Manager 21 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s23)"
                    editable           = "en_m21 and en_s23"
                    default            = "True"
                    title              = "Manager 21 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s24)"
                    editable           = "en_m21 and en_s24"
                    default            = "True"
                    title              = "Manager 21 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s25)"
                    editable           = "en_m21 and en_s25"
                    default            = "True"
                    title              = "Manager 21 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s26)"
                    editable           = "en_m21 and en_s26"
                    default            = "True"
                    title              = "Manager 21 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s27)"
                    editable           = "en_m21 and en_s27"
                    default            = "True"
                    title              = "Manager 21 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s28)"
                    editable           = "en_m21 and en_s28"
                    default            = "True"
                    title              = "Manager 21 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s29)"
                    editable           = "en_m21 and en_s29"
                    default            = "True"
                    title              = "Manager 21 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s30)"
                    editable           = "en_m21 and en_s30"
                    default            = "True"
                    title              = "Manager 21 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "m21_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m21 and en_s31)"
                    editable           = "en_m21 and en_s31"
                    default            = "True"
                    title              = "Manager 21 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 21 Connection Setting"
                    id                 = "M21_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m21_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s0)"
                    editable           = "en_m22 and en_s0"
                    default            = "True"
                    title              = "Manager 22 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s1)"
                    editable           = "en_m22 and en_s1"
                    default            = "True"
                    title              = "Manager 22 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s2)"
                    editable           = "en_m22 and en_s2"
                    default            = "True"
                    title              = "Manager 22 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s3)"
                    editable           = "en_m22 and en_s3"
                    default            = "True"
                    title              = "Manager 22 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s4)"
                    editable           = "en_m22 and en_s4"
                    default            = "True"
                    title              = "Manager 22 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s5)"
                    editable           = "en_m22 and en_s5"
                    default            = "True"
                    title              = "Manager 22 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s6)"
                    editable           = "en_m22 and en_s6"
                    default            = "True"
                    title              = "Manager 22 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s7)"
                    editable           = "en_m22 and en_s7"
                    default            = "True"
                    title              = "Manager 22 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s8)"
                    editable           = "en_m22 and en_s8"
                    default            = "True"
                    title              = "Manager 22 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s9)"
                    editable           = "en_m22 and en_s9"
                    default            = "True"
                    title              = "Manager 22 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s10)"
                    editable           = "en_m22 and en_s10"
                    default            = "True"
                    title              = "Manager 22 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s11)"
                    editable           = "en_m22 and en_s11"
                    default            = "True"
                    title              = "Manager 22 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s12)"
                    editable           = "en_m22 and en_s12"
                    default            = "True"
                    title              = "Manager 22 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s13)"
                    editable           = "en_m22 and en_s13"
                    default            = "True"
                    title              = "Manager 22 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s14)"
                    editable           = "en_m22 and en_s14"
                    default            = "True"
                    title              = "Manager 22 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s15)"
                    editable           = "en_m22 and en_s15"
                    default            = "True"
                    title              = "Manager 22 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s16)"
                    editable           = "en_m22 and en_s16"
                    default            = "True"
                    title              = "Manager 22 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s17)"
                    editable           = "en_m22 and en_s17"
                    default            = "True"
                    title              = "Manager 22 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s18)"
                    editable           = "en_m22 and en_s18"
                    default            = "True"
                    title              = "Manager 22 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s19)"
                    editable           = "en_m22 and en_s19"
                    default            = "True"
                    title              = "Manager 22 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s20)"
                    editable           = "en_m22 and en_s20"
                    default            = "True"
                    title              = "Manager 22 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s21)"
                    editable           = "en_m22 and en_s21"
                    default            = "True"
                    title              = "Manager 22 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s22)"
                    editable           = "en_m22 and en_s22"
                    default            = "True"
                    title              = "Manager 22 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s23)"
                    editable           = "en_m22 and en_s23"
                    default            = "True"
                    title              = "Manager 22 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s24)"
                    editable           = "en_m22 and en_s24"
                    default            = "True"
                    title              = "Manager 22 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s25)"
                    editable           = "en_m22 and en_s25"
                    default            = "True"
                    title              = "Manager 22 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s26)"
                    editable           = "en_m22 and en_s26"
                    default            = "True"
                    title              = "Manager 22 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s27)"
                    editable           = "en_m22 and en_s27"
                    default            = "True"
                    title              = "Manager 22 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s28)"
                    editable           = "en_m22 and en_s28"
                    default            = "True"
                    title              = "Manager 22 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s29)"
                    editable           = "en_m22 and en_s29"
                    default            = "True"
                    title              = "Manager 22 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s30)"
                    editable           = "en_m22 and en_s30"
                    default            = "True"
                    title              = "Manager 22 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "m22_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m22 and en_s31)"
                    editable           = "en_m22 and en_s31"
                    default            = "True"
                    title              = "Manager 22 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 22 Connection Setting"
                    id                 = "M22_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m22_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s0)"
                    editable           = "en_m23 and en_s0"
                    default            = "True"
                    title              = "Manager 23 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s1)"
                    editable           = "en_m23 and en_s1"
                    default            = "True"
                    title              = "Manager 23 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s2)"
                    editable           = "en_m23 and en_s2"
                    default            = "True"
                    title              = "Manager 23 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s3)"
                    editable           = "en_m23 and en_s3"
                    default            = "True"
                    title              = "Manager 23 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s4)"
                    editable           = "en_m23 and en_s4"
                    default            = "True"
                    title              = "Manager 23 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s5)"
                    editable           = "en_m23 and en_s5"
                    default            = "True"
                    title              = "Manager 23 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s6)"
                    editable           = "en_m23 and en_s6"
                    default            = "True"
                    title              = "Manager 23 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s7)"
                    editable           = "en_m23 and en_s7"
                    default            = "True"
                    title              = "Manager 23 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s8)"
                    editable           = "en_m23 and en_s8"
                    default            = "True"
                    title              = "Manager 23 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s9)"
                    editable           = "en_m23 and en_s9"
                    default            = "True"
                    title              = "Manager 23 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s10)"
                    editable           = "en_m23 and en_s10"
                    default            = "True"
                    title              = "Manager 23 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s11)"
                    editable           = "en_m23 and en_s11"
                    default            = "True"
                    title              = "Manager 23 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s12)"
                    editable           = "en_m23 and en_s12"
                    default            = "True"
                    title              = "Manager 23 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s13)"
                    editable           = "en_m23 and en_s13"
                    default            = "True"
                    title              = "Manager 23 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s14)"
                    editable           = "en_m23 and en_s14"
                    default            = "True"
                    title              = "Manager 23 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s15)"
                    editable           = "en_m23 and en_s15"
                    default            = "True"
                    title              = "Manager 23 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s16)"
                    editable           = "en_m23 and en_s16"
                    default            = "True"
                    title              = "Manager 23 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s17)"
                    editable           = "en_m23 and en_s17"
                    default            = "True"
                    title              = "Manager 23 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s18)"
                    editable           = "en_m23 and en_s18"
                    default            = "True"
                    title              = "Manager 23 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s19)"
                    editable           = "en_m23 and en_s19"
                    default            = "True"
                    title              = "Manager 23 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s20)"
                    editable           = "en_m23 and en_s20"
                    default            = "True"
                    title              = "Manager 23 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s21)"
                    editable           = "en_m23 and en_s21"
                    default            = "True"
                    title              = "Manager 23 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s22)"
                    editable           = "en_m23 and en_s22"
                    default            = "True"
                    title              = "Manager 23 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s23)"
                    editable           = "en_m23 and en_s23"
                    default            = "True"
                    title              = "Manager 23 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s24)"
                    editable           = "en_m23 and en_s24"
                    default            = "True"
                    title              = "Manager 23 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s25)"
                    editable           = "en_m23 and en_s25"
                    default            = "True"
                    title              = "Manager 23 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s26)"
                    editable           = "en_m23 and en_s26"
                    default            = "True"
                    title              = "Manager 23 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s27)"
                    editable           = "en_m23 and en_s27"
                    default            = "True"
                    title              = "Manager 23 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s28)"
                    editable           = "en_m23 and en_s28"
                    default            = "True"
                    title              = "Manager 23 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s29)"
                    editable           = "en_m23 and en_s29"
                    default            = "True"
                    title              = "Manager 23 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s30)"
                    editable           = "en_m23 and en_s30"
                    default            = "True"
                    title              = "Manager 23 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "m23_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m23 and en_s31)"
                    editable           = "en_m23 and en_s31"
                    default            = "True"
                    title              = "Manager 23 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 23 Connection Setting"
                    id                 = "M23_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m23_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s0)"
                    editable           = "en_m24 and en_s0"
                    default            = "True"
                    title              = "Manager 24 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s1)"
                    editable           = "en_m24 and en_s1"
                    default            = "True"
                    title              = "Manager 24 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s2)"
                    editable           = "en_m24 and en_s2"
                    default            = "True"
                    title              = "Manager 24 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s3)"
                    editable           = "en_m24 and en_s3"
                    default            = "True"
                    title              = "Manager 24 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s4)"
                    editable           = "en_m24 and en_s4"
                    default            = "True"
                    title              = "Manager 24 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s5)"
                    editable           = "en_m24 and en_s5"
                    default            = "True"
                    title              = "Manager 24 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s6)"
                    editable           = "en_m24 and en_s6"
                    default            = "True"
                    title              = "Manager 24 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s7)"
                    editable           = "en_m24 and en_s7"
                    default            = "True"
                    title              = "Manager 24 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s8)"
                    editable           = "en_m24 and en_s8"
                    default            = "True"
                    title              = "Manager 24 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s9)"
                    editable           = "en_m24 and en_s9"
                    default            = "True"
                    title              = "Manager 24 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s10)"
                    editable           = "en_m24 and en_s10"
                    default            = "True"
                    title              = "Manager 24 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s11)"
                    editable           = "en_m24 and en_s11"
                    default            = "True"
                    title              = "Manager 24 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s12)"
                    editable           = "en_m24 and en_s12"
                    default            = "True"
                    title              = "Manager 24 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s13)"
                    editable           = "en_m24 and en_s13"
                    default            = "True"
                    title              = "Manager 24 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s14)"
                    editable           = "en_m24 and en_s14"
                    default            = "True"
                    title              = "Manager 24 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s15)"
                    editable           = "en_m24 and en_s15"
                    default            = "True"
                    title              = "Manager 24 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s16)"
                    editable           = "en_m24 and en_s16"
                    default            = "True"
                    title              = "Manager 24 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s17)"
                    editable           = "en_m24 and en_s17"
                    default            = "True"
                    title              = "Manager 24 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s18)"
                    editable           = "en_m24 and en_s18"
                    default            = "True"
                    title              = "Manager 24 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s19)"
                    editable           = "en_m24 and en_s19"
                    default            = "True"
                    title              = "Manager 24 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s20)"
                    editable           = "en_m24 and en_s20"
                    default            = "True"
                    title              = "Manager 24 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s21)"
                    editable           = "en_m24 and en_s21"
                    default            = "True"
                    title              = "Manager 24 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s22)"
                    editable           = "en_m24 and en_s22"
                    default            = "True"
                    title              = "Manager 24 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s23)"
                    editable           = "en_m24 and en_s23"
                    default            = "True"
                    title              = "Manager 24 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s24)"
                    editable           = "en_m24 and en_s24"
                    default            = "True"
                    title              = "Manager 24 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s25)"
                    editable           = "en_m24 and en_s25"
                    default            = "True"
                    title              = "Manager 24 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s26)"
                    editable           = "en_m24 and en_s26"
                    default            = "True"
                    title              = "Manager 24 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s27)"
                    editable           = "en_m24 and en_s27"
                    default            = "True"
                    title              = "Manager 24 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s28)"
                    editable           = "en_m24 and en_s28"
                    default            = "True"
                    title              = "Manager 24 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s29)"
                    editable           = "en_m24 and en_s29"
                    default            = "True"
                    title              = "Manager 24 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s30)"
                    editable           = "en_m24 and en_s30"
                    default            = "True"
                    title              = "Manager 24 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "m24_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m24 and en_s31)"
                    editable           = "en_m24 and en_s31"
                    default            = "True"
                    title              = "Manager 24 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 24 Connection Setting"
                    id                 = "M24_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m24_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s0)"
                    editable           = "en_m25 and en_s0"
                    default            = "True"
                    title              = "Manager 25 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s1)"
                    editable           = "en_m25 and en_s1"
                    default            = "True"
                    title              = "Manager 25 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s2)"
                    editable           = "en_m25 and en_s2"
                    default            = "True"
                    title              = "Manager 25 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s3)"
                    editable           = "en_m25 and en_s3"
                    default            = "True"
                    title              = "Manager 25 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s4)"
                    editable           = "en_m25 and en_s4"
                    default            = "True"
                    title              = "Manager 25 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s5)"
                    editable           = "en_m25 and en_s5"
                    default            = "True"
                    title              = "Manager 25 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s6)"
                    editable           = "en_m25 and en_s6"
                    default            = "True"
                    title              = "Manager 25 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s7)"
                    editable           = "en_m25 and en_s7"
                    default            = "True"
                    title              = "Manager 25 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s8)"
                    editable           = "en_m25 and en_s8"
                    default            = "True"
                    title              = "Manager 25 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s9)"
                    editable           = "en_m25 and en_s9"
                    default            = "True"
                    title              = "Manager 25 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s10)"
                    editable           = "en_m25 and en_s10"
                    default            = "True"
                    title              = "Manager 25 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s11)"
                    editable           = "en_m25 and en_s11"
                    default            = "True"
                    title              = "Manager 25 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s12)"
                    editable           = "en_m25 and en_s12"
                    default            = "True"
                    title              = "Manager 25 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s13)"
                    editable           = "en_m25 and en_s13"
                    default            = "True"
                    title              = "Manager 25 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s14)"
                    editable           = "en_m25 and en_s14"
                    default            = "True"
                    title              = "Manager 25 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s15)"
                    editable           = "en_m25 and en_s15"
                    default            = "True"
                    title              = "Manager 25 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s16)"
                    editable           = "en_m25 and en_s16"
                    default            = "True"
                    title              = "Manager 25 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s17)"
                    editable           = "en_m25 and en_s17"
                    default            = "True"
                    title              = "Manager 25 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s18)"
                    editable           = "en_m25 and en_s18"
                    default            = "True"
                    title              = "Manager 25 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s19)"
                    editable           = "en_m25 and en_s19"
                    default            = "True"
                    title              = "Manager 25 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s20)"
                    editable           = "en_m25 and en_s20"
                    default            = "True"
                    title              = "Manager 25 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s21)"
                    editable           = "en_m25 and en_s21"
                    default            = "True"
                    title              = "Manager 25 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s22)"
                    editable           = "en_m25 and en_s22"
                    default            = "True"
                    title              = "Manager 25 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s23)"
                    editable           = "en_m25 and en_s23"
                    default            = "True"
                    title              = "Manager 25 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s24)"
                    editable           = "en_m25 and en_s24"
                    default            = "True"
                    title              = "Manager 25 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s25)"
                    editable           = "en_m25 and en_s25"
                    default            = "True"
                    title              = "Manager 25 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s26)"
                    editable           = "en_m25 and en_s26"
                    default            = "True"
                    title              = "Manager 25 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s27)"
                    editable           = "en_m25 and en_s27"
                    default            = "True"
                    title              = "Manager 25 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s28)"
                    editable           = "en_m25 and en_s28"
                    default            = "True"
                    title              = "Manager 25 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s29)"
                    editable           = "en_m25 and en_s29"
                    default            = "True"
                    title              = "Manager 25 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s30)"
                    editable           = "en_m25 and en_s30"
                    default            = "True"
                    title              = "Manager 25 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "m25_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m25 and en_s31)"
                    editable           = "en_m25 and en_s31"
                    default            = "True"
                    title              = "Manager 25 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 25 Connection Setting"
                    id                 = "M25_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m25_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s0)"
                    editable           = "en_m26 and en_s0"
                    default            = "True"
                    title              = "Manager 26 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s1)"
                    editable           = "en_m26 and en_s1"
                    default            = "True"
                    title              = "Manager 26 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s2)"
                    editable           = "en_m26 and en_s2"
                    default            = "True"
                    title              = "Manager 26 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s3)"
                    editable           = "en_m26 and en_s3"
                    default            = "True"
                    title              = "Manager 26 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s4)"
                    editable           = "en_m26 and en_s4"
                    default            = "True"
                    title              = "Manager 26 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s5)"
                    editable           = "en_m26 and en_s5"
                    default            = "True"
                    title              = "Manager 26 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s6)"
                    editable           = "en_m26 and en_s6"
                    default            = "True"
                    title              = "Manager 26 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s7)"
                    editable           = "en_m26 and en_s7"
                    default            = "True"
                    title              = "Manager 26 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s8)"
                    editable           = "en_m26 and en_s8"
                    default            = "True"
                    title              = "Manager 26 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s9)"
                    editable           = "en_m26 and en_s9"
                    default            = "True"
                    title              = "Manager 26 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s10)"
                    editable           = "en_m26 and en_s10"
                    default            = "True"
                    title              = "Manager 26 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s11)"
                    editable           = "en_m26 and en_s11"
                    default            = "True"
                    title              = "Manager 26 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s12)"
                    editable           = "en_m26 and en_s12"
                    default            = "True"
                    title              = "Manager 26 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s13)"
                    editable           = "en_m26 and en_s13"
                    default            = "True"
                    title              = "Manager 26 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s14)"
                    editable           = "en_m26 and en_s14"
                    default            = "True"
                    title              = "Manager 26 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s15)"
                    editable           = "en_m26 and en_s15"
                    default            = "True"
                    title              = "Manager 26 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s16)"
                    editable           = "en_m26 and en_s16"
                    default            = "True"
                    title              = "Manager 26 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s17)"
                    editable           = "en_m26 and en_s17"
                    default            = "True"
                    title              = "Manager 26 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s18)"
                    editable           = "en_m26 and en_s18"
                    default            = "True"
                    title              = "Manager 26 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s19)"
                    editable           = "en_m26 and en_s19"
                    default            = "True"
                    title              = "Manager 26 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s20)"
                    editable           = "en_m26 and en_s20"
                    default            = "True"
                    title              = "Manager 26 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s21)"
                    editable           = "en_m26 and en_s21"
                    default            = "True"
                    title              = "Manager 26 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s22)"
                    editable           = "en_m26 and en_s22"
                    default            = "True"
                    title              = "Manager 26 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s23)"
                    editable           = "en_m26 and en_s23"
                    default            = "True"
                    title              = "Manager 26 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s24)"
                    editable           = "en_m26 and en_s24"
                    default            = "True"
                    title              = "Manager 26 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s25)"
                    editable           = "en_m26 and en_s25"
                    default            = "True"
                    title              = "Manager 26 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s26)"
                    editable           = "en_m26 and en_s26"
                    default            = "True"
                    title              = "Manager 26 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s27)"
                    editable           = "en_m26 and en_s27"
                    default            = "True"
                    title              = "Manager 26 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s28)"
                    editable           = "en_m26 and en_s28"
                    default            = "True"
                    title              = "Manager 26 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s29)"
                    editable           = "en_m26 and en_s29"
                    default            = "True"
                    title              = "Manager 26 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s30)"
                    editable           = "en_m26 and en_s30"
                    default            = "True"
                    title              = "Manager 26 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "m26_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m26 and en_s31)"
                    editable           = "en_m26 and en_s31"
                    default            = "True"
                    title              = "Manager 26 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 26 Connection Setting"
                    id                 = "M26_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m26_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s0)"
                    editable           = "en_m27 and en_s0"
                    default            = "True"
                    title              = "Manager 27 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s1)"
                    editable           = "en_m27 and en_s1"
                    default            = "True"
                    title              = "Manager 27 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s2)"
                    editable           = "en_m27 and en_s2"
                    default            = "True"
                    title              = "Manager 27 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s3)"
                    editable           = "en_m27 and en_s3"
                    default            = "True"
                    title              = "Manager 27 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s4)"
                    editable           = "en_m27 and en_s4"
                    default            = "True"
                    title              = "Manager 27 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s5)"
                    editable           = "en_m27 and en_s5"
                    default            = "True"
                    title              = "Manager 27 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s6)"
                    editable           = "en_m27 and en_s6"
                    default            = "True"
                    title              = "Manager 27 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s7)"
                    editable           = "en_m27 and en_s7"
                    default            = "True"
                    title              = "Manager 27 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s8)"
                    editable           = "en_m27 and en_s8"
                    default            = "True"
                    title              = "Manager 27 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s9)"
                    editable           = "en_m27 and en_s9"
                    default            = "True"
                    title              = "Manager 27 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s10)"
                    editable           = "en_m27 and en_s10"
                    default            = "True"
                    title              = "Manager 27 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s11)"
                    editable           = "en_m27 and en_s11"
                    default            = "True"
                    title              = "Manager 27 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s12)"
                    editable           = "en_m27 and en_s12"
                    default            = "True"
                    title              = "Manager 27 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s13)"
                    editable           = "en_m27 and en_s13"
                    default            = "True"
                    title              = "Manager 27 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s14)"
                    editable           = "en_m27 and en_s14"
                    default            = "True"
                    title              = "Manager 27 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s15)"
                    editable           = "en_m27 and en_s15"
                    default            = "True"
                    title              = "Manager 27 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s16)"
                    editable           = "en_m27 and en_s16"
                    default            = "True"
                    title              = "Manager 27 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s17)"
                    editable           = "en_m27 and en_s17"
                    default            = "True"
                    title              = "Manager 27 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s18)"
                    editable           = "en_m27 and en_s18"
                    default            = "True"
                    title              = "Manager 27 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s19)"
                    editable           = "en_m27 and en_s19"
                    default            = "True"
                    title              = "Manager 27 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s20)"
                    editable           = "en_m27 and en_s20"
                    default            = "True"
                    title              = "Manager 27 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s21)"
                    editable           = "en_m27 and en_s21"
                    default            = "True"
                    title              = "Manager 27 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s22)"
                    editable           = "en_m27 and en_s22"
                    default            = "True"
                    title              = "Manager 27 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s23)"
                    editable           = "en_m27 and en_s23"
                    default            = "True"
                    title              = "Manager 27 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s24)"
                    editable           = "en_m27 and en_s24"
                    default            = "True"
                    title              = "Manager 27 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s25)"
                    editable           = "en_m27 and en_s25"
                    default            = "True"
                    title              = "Manager 27 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s26)"
                    editable           = "en_m27 and en_s26"
                    default            = "True"
                    title              = "Manager 27 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s27)"
                    editable           = "en_m27 and en_s27"
                    default            = "True"
                    title              = "Manager 27 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s28)"
                    editable           = "en_m27 and en_s28"
                    default            = "True"
                    title              = "Manager 27 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s29)"
                    editable           = "en_m27 and en_s29"
                    default            = "True"
                    title              = "Manager 27 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s30)"
                    editable           = "en_m27 and en_s30"
                    default            = "True"
                    title              = "Manager 27 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "m27_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m27 and en_s31)"
                    editable           = "en_m27 and en_s31"
                    default            = "True"
                    title              = "Manager 27 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 27 Connection Setting"
                    id                 = "M27_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m27_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s0)"
                    editable           = "en_m28 and en_s0"
                    default            = "True"
                    title              = "Manager 28 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s1)"
                    editable           = "en_m28 and en_s1"
                    default            = "True"
                    title              = "Manager 28 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s2)"
                    editable           = "en_m28 and en_s2"
                    default            = "True"
                    title              = "Manager 28 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s3)"
                    editable           = "en_m28 and en_s3"
                    default            = "True"
                    title              = "Manager 28 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s4)"
                    editable           = "en_m28 and en_s4"
                    default            = "True"
                    title              = "Manager 28 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s5)"
                    editable           = "en_m28 and en_s5"
                    default            = "True"
                    title              = "Manager 28 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s6)"
                    editable           = "en_m28 and en_s6"
                    default            = "True"
                    title              = "Manager 28 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s7)"
                    editable           = "en_m28 and en_s7"
                    default            = "True"
                    title              = "Manager 28 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s8)"
                    editable           = "en_m28 and en_s8"
                    default            = "True"
                    title              = "Manager 28 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s9)"
                    editable           = "en_m28 and en_s9"
                    default            = "True"
                    title              = "Manager 28 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s10)"
                    editable           = "en_m28 and en_s10"
                    default            = "True"
                    title              = "Manager 28 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s11)"
                    editable           = "en_m28 and en_s11"
                    default            = "True"
                    title              = "Manager 28 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s12)"
                    editable           = "en_m28 and en_s12"
                    default            = "True"
                    title              = "Manager 28 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s13)"
                    editable           = "en_m28 and en_s13"
                    default            = "True"
                    title              = "Manager 28 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s14)"
                    editable           = "en_m28 and en_s14"
                    default            = "True"
                    title              = "Manager 28 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s15)"
                    editable           = "en_m28 and en_s15"
                    default            = "True"
                    title              = "Manager 28 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s16)"
                    editable           = "en_m28 and en_s16"
                    default            = "True"
                    title              = "Manager 28 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s17)"
                    editable           = "en_m28 and en_s17"
                    default            = "True"
                    title              = "Manager 28 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s18)"
                    editable           = "en_m28 and en_s18"
                    default            = "True"
                    title              = "Manager 28 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s19)"
                    editable           = "en_m28 and en_s19"
                    default            = "True"
                    title              = "Manager 28 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s20)"
                    editable           = "en_m28 and en_s20"
                    default            = "True"
                    title              = "Manager 28 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s21)"
                    editable           = "en_m28 and en_s21"
                    default            = "True"
                    title              = "Manager 28 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s22)"
                    editable           = "en_m28 and en_s22"
                    default            = "True"
                    title              = "Manager 28 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s23)"
                    editable           = "en_m28 and en_s23"
                    default            = "True"
                    title              = "Manager 28 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s24)"
                    editable           = "en_m28 and en_s24"
                    default            = "True"
                    title              = "Manager 28 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s25)"
                    editable           = "en_m28 and en_s25"
                    default            = "True"
                    title              = "Manager 28 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s26)"
                    editable           = "en_m28 and en_s26"
                    default            = "True"
                    title              = "Manager 28 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s27)"
                    editable           = "en_m28 and en_s27"
                    default            = "True"
                    title              = "Manager 28 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s28)"
                    editable           = "en_m28 and en_s28"
                    default            = "True"
                    title              = "Manager 28 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s29)"
                    editable           = "en_m28 and en_s29"
                    default            = "True"
                    title              = "Manager 28 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s30)"
                    editable           = "en_m28 and en_s30"
                    default            = "True"
                    title              = "Manager 28 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "m28_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m28 and en_s31)"
                    editable           = "en_m28 and en_s31"
                    default            = "True"
                    title              = "Manager 28 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 28 Connection Setting"
                    id                 = "M28_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m28_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s0)"
                    editable           = "en_m29 and en_s0"
                    default            = "True"
                    title              = "Manager 29 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s1)"
                    editable           = "en_m29 and en_s1"
                    default            = "True"
                    title              = "Manager 29 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s2)"
                    editable           = "en_m29 and en_s2"
                    default            = "True"
                    title              = "Manager 29 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s3)"
                    editable           = "en_m29 and en_s3"
                    default            = "True"
                    title              = "Manager 29 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s4)"
                    editable           = "en_m29 and en_s4"
                    default            = "True"
                    title              = "Manager 29 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s5)"
                    editable           = "en_m29 and en_s5"
                    default            = "True"
                    title              = "Manager 29 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s6)"
                    editable           = "en_m29 and en_s6"
                    default            = "True"
                    title              = "Manager 29 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s7)"
                    editable           = "en_m29 and en_s7"
                    default            = "True"
                    title              = "Manager 29 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s8)"
                    editable           = "en_m29 and en_s8"
                    default            = "True"
                    title              = "Manager 29 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s9)"
                    editable           = "en_m29 and en_s9"
                    default            = "True"
                    title              = "Manager 29 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s10)"
                    editable           = "en_m29 and en_s10"
                    default            = "True"
                    title              = "Manager 29 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s11)"
                    editable           = "en_m29 and en_s11"
                    default            = "True"
                    title              = "Manager 29 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s12)"
                    editable           = "en_m29 and en_s12"
                    default            = "True"
                    title              = "Manager 29 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s13)"
                    editable           = "en_m29 and en_s13"
                    default            = "True"
                    title              = "Manager 29 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s14)"
                    editable           = "en_m29 and en_s14"
                    default            = "True"
                    title              = "Manager 29 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s15)"
                    editable           = "en_m29 and en_s15"
                    default            = "True"
                    title              = "Manager 29 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s16)"
                    editable           = "en_m29 and en_s16"
                    default            = "True"
                    title              = "Manager 29 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s17)"
                    editable           = "en_m29 and en_s17"
                    default            = "True"
                    title              = "Manager 29 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s18)"
                    editable           = "en_m29 and en_s18"
                    default            = "True"
                    title              = "Manager 29 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s19)"
                    editable           = "en_m29 and en_s19"
                    default            = "True"
                    title              = "Manager 29 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s20)"
                    editable           = "en_m29 and en_s20"
                    default            = "True"
                    title              = "Manager 29 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s21)"
                    editable           = "en_m29 and en_s21"
                    default            = "True"
                    title              = "Manager 29 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s22)"
                    editable           = "en_m29 and en_s22"
                    default            = "True"
                    title              = "Manager 29 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s23)"
                    editable           = "en_m29 and en_s23"
                    default            = "True"
                    title              = "Manager 29 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s24)"
                    editable           = "en_m29 and en_s24"
                    default            = "True"
                    title              = "Manager 29 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s25)"
                    editable           = "en_m29 and en_s25"
                    default            = "True"
                    title              = "Manager 29 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s26)"
                    editable           = "en_m29 and en_s26"
                    default            = "True"
                    title              = "Manager 29 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s27)"
                    editable           = "en_m29 and en_s27"
                    default            = "True"
                    title              = "Manager 29 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s28)"
                    editable           = "en_m29 and en_s28"
                    default            = "True"
                    title              = "Manager 29 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s29)"
                    editable           = "en_m29 and en_s29"
                    default            = "True"
                    title              = "Manager 29 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s30)"
                    editable           = "en_m29 and en_s30"
                    default            = "True"
                    title              = "Manager 29 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "m29_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m29 and en_s31)"
                    editable           = "en_m29 and en_s31"
                    default            = "True"
                    title              = "Manager 29 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 29 Connection Setting"
                    id                 = "M29_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m29_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s0)"
                    editable           = "en_m30 and en_s0"
                    default            = "True"
                    title              = "Manager 30 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s1)"
                    editable           = "en_m30 and en_s1"
                    default            = "True"
                    title              = "Manager 30 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s2)"
                    editable           = "en_m30 and en_s2"
                    default            = "True"
                    title              = "Manager 30 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s3)"
                    editable           = "en_m30 and en_s3"
                    default            = "True"
                    title              = "Manager 30 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s4)"
                    editable           = "en_m30 and en_s4"
                    default            = "True"
                    title              = "Manager 30 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s5)"
                    editable           = "en_m30 and en_s5"
                    default            = "True"
                    title              = "Manager 30 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s6)"
                    editable           = "en_m30 and en_s6"
                    default            = "True"
                    title              = "Manager 30 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s7)"
                    editable           = "en_m30 and en_s7"
                    default            = "True"
                    title              = "Manager 30 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s8)"
                    editable           = "en_m30 and en_s8"
                    default            = "True"
                    title              = "Manager 30 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s9)"
                    editable           = "en_m30 and en_s9"
                    default            = "True"
                    title              = "Manager 30 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s10)"
                    editable           = "en_m30 and en_s10"
                    default            = "True"
                    title              = "Manager 30 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s11)"
                    editable           = "en_m30 and en_s11"
                    default            = "True"
                    title              = "Manager 30 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s12)"
                    editable           = "en_m30 and en_s12"
                    default            = "True"
                    title              = "Manager 30 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s13)"
                    editable           = "en_m30 and en_s13"
                    default            = "True"
                    title              = "Manager 30 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s14)"
                    editable           = "en_m30 and en_s14"
                    default            = "True"
                    title              = "Manager 30 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s15)"
                    editable           = "en_m30 and en_s15"
                    default            = "True"
                    title              = "Manager 30 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s16)"
                    editable           = "en_m30 and en_s16"
                    default            = "True"
                    title              = "Manager 30 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s17)"
                    editable           = "en_m30 and en_s17"
                    default            = "True"
                    title              = "Manager 30 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s18)"
                    editable           = "en_m30 and en_s18"
                    default            = "True"
                    title              = "Manager 30 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s19)"
                    editable           = "en_m30 and en_s19"
                    default            = "True"
                    title              = "Manager 30 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s20)"
                    editable           = "en_m30 and en_s20"
                    default            = "True"
                    title              = "Manager 30 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s21)"
                    editable           = "en_m30 and en_s21"
                    default            = "True"
                    title              = "Manager 30 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s22)"
                    editable           = "en_m30 and en_s22"
                    default            = "True"
                    title              = "Manager 30 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s23)"
                    editable           = "en_m30 and en_s23"
                    default            = "True"
                    title              = "Manager 30 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s24)"
                    editable           = "en_m30 and en_s24"
                    default            = "True"
                    title              = "Manager 30 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s25)"
                    editable           = "en_m30 and en_s25"
                    default            = "True"
                    title              = "Manager 30 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s26)"
                    editable           = "en_m30 and en_s26"
                    default            = "True"
                    title              = "Manager 30 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s27)"
                    editable           = "en_m30 and en_s27"
                    default            = "True"
                    title              = "Manager 30 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s28)"
                    editable           = "en_m30 and en_s28"
                    default            = "True"
                    title              = "Manager 30 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s29)"
                    editable           = "en_m30 and en_s29"
                    default            = "True"
                    title              = "Manager 30 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s30)"
                    editable           = "en_m30 and en_s30"
                    default            = "True"
                    title              = "Manager 30 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "m30_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m30 and en_s31)"
                    editable           = "en_m30 and en_s31"
                    default            = "True"
                    title              = "Manager 30 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 30 Connection Setting"
                    id                 = "M30_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m30_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s0_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s0)"
                    editable           = "en_m31 and en_s0"
                    default            = "True"
                    title              = "Manager 31 Subordinate 0 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S0_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s0_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s1_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s1)"
                    editable           = "en_m31 and en_s1"
                    default            = "True"
                    title              = "Manager 31 Subordinate 1 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S1_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s1_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s2_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s2)"
                    editable           = "en_m31 and en_s2"
                    default            = "True"
                    title              = "Manager 31 Subordinate 2 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S2_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s2_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s3_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s3)"
                    editable           = "en_m31 and en_s3"
                    default            = "True"
                    title              = "Manager 31 Subordinate 3 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S3_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s3_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s4_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s4)"
                    editable           = "en_m31 and en_s4"
                    default            = "True"
                    title              = "Manager 31 Subordinate 4 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S4_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s4_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s5_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s5)"
                    editable           = "en_m31 and en_s5"
                    default            = "True"
                    title              = "Manager 31 Subordinate 5 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S5_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s5_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s6_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s6)"
                    editable           = "en_m31 and en_s6"
                    default            = "True"
                    title              = "Manager 31 Subordinate 6 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S6_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s6_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s7_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s7)"
                    editable           = "en_m31 and en_s7"
                    default            = "True"
                    title              = "Manager 31 Subordinate 7 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S7_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s7_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s8_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s8)"
                    editable           = "en_m31 and en_s8"
                    default            = "True"
                    title              = "Manager 31 Subordinate 8 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S8_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s8_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s9_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s9)"
                    editable           = "en_m31 and en_s9"
                    default            = "True"
                    title              = "Manager 31 Subordinate 9 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S9_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s9_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s10_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s10)"
                    editable           = "en_m31 and en_s10"
                    default            = "True"
                    title              = "Manager 31 Subordinate 10 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S10_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s10_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s11_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s11)"
                    editable           = "en_m31 and en_s11"
                    default            = "True"
                    title              = "Manager 31 Subordinate 11 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S11_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s11_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s12_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s12)"
                    editable           = "en_m31 and en_s12"
                    default            = "True"
                    title              = "Manager 31 Subordinate 12 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S12_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s12_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s13_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s13)"
                    editable           = "en_m31 and en_s13"
                    default            = "True"
                    title              = "Manager 31 Subordinate 13 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S13_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s13_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s14_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s14)"
                    editable           = "en_m31 and en_s14"
                    default            = "True"
                    title              = "Manager 31 Subordinate 14 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S14_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s14_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s15_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s15)"
                    editable           = "en_m31 and en_s15"
                    default            = "True"
                    title              = "Manager 31 Subordinate 15 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S15_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s15_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s16_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s16)"
                    editable           = "en_m31 and en_s16"
                    default            = "True"
                    title              = "Manager 31 Subordinate 16 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S16_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s16_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s17_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s17)"
                    editable           = "en_m31 and en_s17"
                    default            = "True"
                    title              = "Manager 31 Subordinate 17 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S17_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s17_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s18_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s18)"
                    editable           = "en_m31 and en_s18"
                    default            = "True"
                    title              = "Manager 31 Subordinate 18 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S18_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s18_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s19_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s19)"
                    editable           = "en_m31 and en_s19"
                    default            = "True"
                    title              = "Manager 31 Subordinate 19 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S19_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s19_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s20_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s20)"
                    editable           = "en_m31 and en_s20"
                    default            = "True"
                    title              = "Manager 31 Subordinate 20 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S20_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s20_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s21_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s21)"
                    editable           = "en_m31 and en_s21"
                    default            = "True"
                    title              = "Manager 31 Subordinate 21 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S21_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s21_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s22_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s22)"
                    editable           = "en_m31 and en_s22"
                    default            = "True"
                    title              = "Manager 31 Subordinate 22 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S22_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s22_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s23_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s23)"
                    editable           = "en_m31 and en_s23"
                    default            = "True"
                    title              = "Manager 31 Subordinate 23 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S23_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s23_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s24_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s24)"
                    editable           = "en_m31 and en_s24"
                    default            = "True"
                    title              = "Manager 31 Subordinate 24 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S24_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s24_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s25_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s25)"
                    editable           = "en_m31 and en_s25"
                    default            = "True"
                    title              = "Manager 31 Subordinate 25 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S25_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s25_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s26_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s26)"
                    editable           = "en_m31 and en_s26"
                    default            = "True"
                    title              = "Manager 31 Subordinate 26 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S26_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s26_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s27_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s27)"
                    editable           = "en_m31 and en_s27"
                    default            = "True"
                    title              = "Manager 31 Subordinate 27 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S27_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s27_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s28_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s28)"
                    editable           = "en_m31 and en_s28"
                    default            = "True"
                    title              = "Manager 31 Subordinate 28 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S28_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s28_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s29_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s29)"
                    editable           = "en_m31 and en_s29"
                    default            = "True"
                    title              = "Manager 31 Subordinate 29 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S29_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s29_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s30_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s30)"
                    editable           = "en_m31 and en_s30"
                    default            = "True"
                    title              = "Manager 31 Subordinate 30 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S30_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s30_conn_en == True) else 0"
                    hidden             = "True"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "m31_s31_conn_en"
                    type               = "input"
                    value_type         = "bool"
                    hidden             = "not(en_m31 and en_s31)"
                    editable           = "en_m31 and en_s31"
                    default            = "True"
                    title              = "Manager 31 Subordinate 31 Connect Enable "
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Manager 31 Connection Setting"
                    id                 = "M31_S31_CONNECT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "False"
                    value_expr         = "1 if (m31_s31_conn_en == True) else 0"
                    hidden             = "True"
    />
  <!-- Subordinate 0 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "S0_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0"
                    config_groups      = "'SystemBuilder' if(en_s0) else 'None'"
                    drc                = "ext_frag_num_drc(0, S0_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 0 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00000000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s0_baddr_0, s0_addr_range_0, M_ADDR_WIDTH, 0, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s0_baddr_1, s0_addr_range_1, M_ADDR_WIDTH, 0, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00000800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s0_baddr_2, s0_addr_range_2, M_ADDR_WIDTH, 0, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00000c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s0_baddr_3, s0_addr_range_3, M_ADDR_WIDTH, 0, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00001000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s0_baddr_4, s0_addr_range_4, M_ADDR_WIDTH, 0, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00001400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s0_baddr_5, s0_addr_range_5, M_ADDR_WIDTH, 0, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00001800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s0_baddr_6, s0_addr_range_6, M_ADDR_WIDTH, 0, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00001c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s0_baddr_7, s0_addr_range_7, M_ADDR_WIDTH, 0, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s0_addr_range_0, s0_baddr_0, 0, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s0_addr_range_1, s0_baddr_1, 0, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s0_addr_range_2, s0_baddr_2, 0, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s0_addr_range_3, s0_baddr_3, 0, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s0_addr_range_4, s0_baddr_4, 0, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s0_addr_range_5, s0_baddr_5, 0, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s0_addr_range_6, s0_baddr_6, 0, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "s0_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s0 and (S0_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s0_addr_range_7, s0_baddr_7, 0, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "S0_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s0) else 'None'"
                    value_expr         = "ext_actual_base_addr(s0_baddr_0, s0_baddr_1, s0_baddr_2, s0_baddr_3, s0_baddr_4, s0_baddr_5, s0_baddr_6, s0_baddr_7, S0_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Main Settings"
                    id                 = "S0_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s0) else 'None'"
                    value_expr         = "ext_actual_base_addr(s0_addr_range_0, s0_addr_range_1, s0_addr_range_2, s0_addr_range_3, s0_addr_range_4, s0_addr_range_5, s0_addr_range_6, s0_addr_range_7, S0_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 1 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "S1_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1"
                    config_groups      = "'SystemBuilder' if(en_s1) else 'None'"
                    drc                = "ext_frag_num_drc(1, S1_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 1 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00002000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s1_baddr_0, s1_addr_range_0, M_ADDR_WIDTH, 1, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00002400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s1_baddr_1, s1_addr_range_1, M_ADDR_WIDTH, 1, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00002800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s1_baddr_2, s1_addr_range_2, M_ADDR_WIDTH, 1, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00002c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s1_baddr_3, s1_addr_range_3, M_ADDR_WIDTH, 1, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00003000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s1_baddr_4, s1_addr_range_4, M_ADDR_WIDTH, 1, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00003400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s1_baddr_5, s1_addr_range_5, M_ADDR_WIDTH, 1, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00003800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s1_baddr_6, s1_addr_range_6, M_ADDR_WIDTH, 1, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00003c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s1_baddr_7, s1_addr_range_7, M_ADDR_WIDTH, 1, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s1_addr_range_0, s1_baddr_0, 1, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s1_addr_range_1, s1_baddr_1, 1, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s1_addr_range_2, s1_baddr_2, 1, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s1_addr_range_3, s1_baddr_3, 1, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s1_addr_range_4, s1_baddr_4, 1, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s1_addr_range_5, s1_baddr_5, 1, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s1_addr_range_6, s1_baddr_6, 1, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "s1_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s1 and (S1_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s1_addr_range_7, s1_baddr_7, 1, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "S1_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s1) else 'None'"
                    value_expr         = "ext_actual_base_addr(s1_baddr_0, s1_baddr_1, s1_baddr_2, s1_baddr_3, s1_baddr_4, s1_baddr_5, s1_baddr_6, s1_baddr_7, S1_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Main Settings"
                    id                 = "S1_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s1) else 'None'"
                    value_expr         = "ext_actual_base_addr(s1_addr_range_0, s1_addr_range_1, s1_addr_range_2, s1_addr_range_3, s1_addr_range_4, s1_addr_range_5, s1_addr_range_6, s1_addr_range_7, S1_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 2 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "S2_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2"
                    config_groups      = "'SystemBuilder' if(en_s2) else 'None'"
                    drc                = "ext_frag_num_drc(2, S2_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 2 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00004000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s2_baddr_0, s2_addr_range_0, M_ADDR_WIDTH, 2, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00004400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s2_baddr_1, s2_addr_range_1, M_ADDR_WIDTH, 2, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00004800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s2_baddr_2, s2_addr_range_2, M_ADDR_WIDTH, 2, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00004c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s2_baddr_3, s2_addr_range_3, M_ADDR_WIDTH, 2, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00005000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s2_baddr_4, s2_addr_range_4, M_ADDR_WIDTH, 2, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00005400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s2_baddr_5, s2_addr_range_5, M_ADDR_WIDTH, 2, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00005800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s2_baddr_6, s2_addr_range_6, M_ADDR_WIDTH, 2, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00005c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s2_baddr_7, s2_addr_range_7, M_ADDR_WIDTH, 2, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s2_addr_range_0, s2_baddr_0, 2, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s2_addr_range_1, s2_baddr_1, 2, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s2_addr_range_2, s2_baddr_2, 2, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s2_addr_range_3, s2_baddr_3, 2, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s2_addr_range_4, s2_baddr_4, 2, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s2_addr_range_5, s2_baddr_5, 2, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s2_addr_range_6, s2_baddr_6, 2, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "s2_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s2 and (S2_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s2_addr_range_7, s2_baddr_7, 2, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "S2_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s2) else 'None'"
                    value_expr         = "ext_actual_base_addr(s2_baddr_0, s2_baddr_1, s2_baddr_2, s2_baddr_3, s2_baddr_4, s2_baddr_5, s2_baddr_6, s2_baddr_7, S2_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Main Settings"
                    id                 = "S2_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s2) else 'None'"
                    value_expr         = "ext_actual_base_addr(s2_addr_range_0, s2_addr_range_1, s2_addr_range_2, s2_addr_range_3, s2_addr_range_4, s2_addr_range_5, s2_addr_range_6, s2_addr_range_7, S2_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 3 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "S3_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3"
                    config_groups      = "'SystemBuilder' if(en_s3) else 'None'"
                    drc                = "ext_frag_num_drc(3, S3_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 3 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00006000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s3_baddr_0, s3_addr_range_0, M_ADDR_WIDTH, 3, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00006400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s3_baddr_1, s3_addr_range_1, M_ADDR_WIDTH, 3, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00006800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s3_baddr_2, s3_addr_range_2, M_ADDR_WIDTH, 3, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00006c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s3_baddr_3, s3_addr_range_3, M_ADDR_WIDTH, 3, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00007000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s3_baddr_4, s3_addr_range_4, M_ADDR_WIDTH, 3, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00007400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s3_baddr_5, s3_addr_range_5, M_ADDR_WIDTH, 3, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00007800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s3_baddr_6, s3_addr_range_6, M_ADDR_WIDTH, 3, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00007c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s3_baddr_7, s3_addr_range_7, M_ADDR_WIDTH, 3, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s3_addr_range_0, s3_baddr_0, 3, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s3_addr_range_1, s3_baddr_1, 3, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s3_addr_range_2, s3_baddr_2, 3, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s3_addr_range_3, s3_baddr_3, 3, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s3_addr_range_4, s3_baddr_4, 3, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s3_addr_range_5, s3_baddr_5, 3, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s3_addr_range_6, s3_baddr_6, 3, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "s3_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s3 and (S3_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s3_addr_range_7, s3_baddr_7, 3, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "S3_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s3) else 'None'"
                    value_expr         = "ext_actual_base_addr(s3_baddr_0, s3_baddr_1, s3_baddr_2, s3_baddr_3, s3_baddr_4, s3_baddr_5, s3_baddr_6, s3_baddr_7, S3_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Main Settings"
                    id                 = "S3_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s3) else 'None'"
                    value_expr         = "ext_actual_base_addr(s3_addr_range_0, s3_addr_range_1, s3_addr_range_2, s3_addr_range_3, s3_addr_range_4, s3_addr_range_5, s3_addr_range_6, s3_addr_range_7, S3_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 4 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "S4_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4"
                    config_groups      = "'SystemBuilder' if(en_s4) else 'None'"
                    drc                = "ext_frag_num_drc(4, S4_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 4 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00008000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s4_baddr_0, s4_addr_range_0, M_ADDR_WIDTH, 4, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00008400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s4_baddr_1, s4_addr_range_1, M_ADDR_WIDTH, 4, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00008800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s4_baddr_2, s4_addr_range_2, M_ADDR_WIDTH, 4, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00008c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s4_baddr_3, s4_addr_range_3, M_ADDR_WIDTH, 4, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00009000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s4_baddr_4, s4_addr_range_4, M_ADDR_WIDTH, 4, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00009400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s4_baddr_5, s4_addr_range_5, M_ADDR_WIDTH, 4, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00009800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s4_baddr_6, s4_addr_range_6, M_ADDR_WIDTH, 4, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00009c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s4_baddr_7, s4_addr_range_7, M_ADDR_WIDTH, 4, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s4_addr_range_0, s4_baddr_0, 4, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s4_addr_range_1, s4_baddr_1, 4, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s4_addr_range_2, s4_baddr_2, 4, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s4_addr_range_3, s4_baddr_3, 4, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s4_addr_range_4, s4_baddr_4, 4, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s4_addr_range_5, s4_baddr_5, 4, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s4_addr_range_6, s4_baddr_6, 4, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "s4_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s4 and (S4_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s4_addr_range_7, s4_baddr_7, 4, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "S4_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s4) else 'None'"
                    value_expr         = "ext_actual_base_addr(s4_baddr_0, s4_baddr_1, s4_baddr_2, s4_baddr_3, s4_baddr_4, s4_baddr_5, s4_baddr_6, s4_baddr_7, S4_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Main Settings"
                    id                 = "S4_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s4) else 'None'"
                    value_expr         = "ext_actual_base_addr(s4_addr_range_0, s4_addr_range_1, s4_addr_range_2, s4_addr_range_3, s4_addr_range_4, s4_addr_range_5, s4_addr_range_6, s4_addr_range_7, S4_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 5 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "S5_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5"
                    config_groups      = "'SystemBuilder' if(en_s5) else 'None'"
                    drc                = "ext_frag_num_drc(5, S5_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 5 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000a000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s5_baddr_0, s5_addr_range_0, M_ADDR_WIDTH, 5, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000a400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s5_baddr_1, s5_addr_range_1, M_ADDR_WIDTH, 5, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000a800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s5_baddr_2, s5_addr_range_2, M_ADDR_WIDTH, 5, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000ac00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s5_baddr_3, s5_addr_range_3, M_ADDR_WIDTH, 5, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000b000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s5_baddr_4, s5_addr_range_4, M_ADDR_WIDTH, 5, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000b400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s5_baddr_5, s5_addr_range_5, M_ADDR_WIDTH, 5, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000b800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s5_baddr_6, s5_addr_range_6, M_ADDR_WIDTH, 5, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000bc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s5_baddr_7, s5_addr_range_7, M_ADDR_WIDTH, 5, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s5_addr_range_0, s5_baddr_0, 5, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s5_addr_range_1, s5_baddr_1, 5, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s5_addr_range_2, s5_baddr_2, 5, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s5_addr_range_3, s5_baddr_3, 5, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s5_addr_range_4, s5_baddr_4, 5, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s5_addr_range_5, s5_baddr_5, 5, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s5_addr_range_6, s5_baddr_6, 5, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "s5_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s5 and (S5_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s5_addr_range_7, s5_baddr_7, 5, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "S5_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s5) else 'None'"
                    value_expr         = "ext_actual_base_addr(s5_baddr_0, s5_baddr_1, s5_baddr_2, s5_baddr_3, s5_baddr_4, s5_baddr_5, s5_baddr_6, s5_baddr_7, S5_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Main Settings"
                    id                 = "S5_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s5) else 'None'"
                    value_expr         = "ext_actual_base_addr(s5_addr_range_0, s5_addr_range_1, s5_addr_range_2, s5_addr_range_3, s5_addr_range_4, s5_addr_range_5, s5_addr_range_6, s5_addr_range_7, S5_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 6 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "S6_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6"
                    config_groups      = "'SystemBuilder' if(en_s6) else 'None'"
                    drc                = "ext_frag_num_drc(6, S6_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 6 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000c000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s6_baddr_0, s6_addr_range_0, M_ADDR_WIDTH, 6, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000c400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s6_baddr_1, s6_addr_range_1, M_ADDR_WIDTH, 6, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000c800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s6_baddr_2, s6_addr_range_2, M_ADDR_WIDTH, 6, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000cc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s6_baddr_3, s6_addr_range_3, M_ADDR_WIDTH, 6, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000d000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s6_baddr_4, s6_addr_range_4, M_ADDR_WIDTH, 6, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000d400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s6_baddr_5, s6_addr_range_5, M_ADDR_WIDTH, 6, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000d800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s6_baddr_6, s6_addr_range_6, M_ADDR_WIDTH, 6, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000dc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s6_baddr_7, s6_addr_range_7, M_ADDR_WIDTH, 6, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s6_addr_range_0, s6_baddr_0, 6, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s6_addr_range_1, s6_baddr_1, 6, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s6_addr_range_2, s6_baddr_2, 6, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s6_addr_range_3, s6_baddr_3, 6, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s6_addr_range_4, s6_baddr_4, 6, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s6_addr_range_5, s6_baddr_5, 6, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s6_addr_range_6, s6_baddr_6, 6, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "s6_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s6 and (S6_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s6_addr_range_7, s6_baddr_7, 6, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "S6_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s6) else 'None'"
                    value_expr         = "ext_actual_base_addr(s6_baddr_0, s6_baddr_1, s6_baddr_2, s6_baddr_3, s6_baddr_4, s6_baddr_5, s6_baddr_6, s6_baddr_7, S6_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Main Settings"
                    id                 = "S6_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s6) else 'None'"
                    value_expr         = "ext_actual_base_addr(s6_addr_range_0, s6_addr_range_1, s6_addr_range_2, s6_addr_range_3, s6_addr_range_4, s6_addr_range_5, s6_addr_range_6, s6_addr_range_7, S6_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 7 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "S7_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7"
                    config_groups      = "'SystemBuilder' if(en_s7) else 'None'"
                    drc                = "ext_frag_num_drc(7, S7_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 7 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000e000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s7_baddr_0, s7_addr_range_0, M_ADDR_WIDTH, 7, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000e400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s7_baddr_1, s7_addr_range_1, M_ADDR_WIDTH, 7, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000e800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s7_baddr_2, s7_addr_range_2, M_ADDR_WIDTH, 7, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000ec00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s7_baddr_3, s7_addr_range_3, M_ADDR_WIDTH, 7, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000f000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s7_baddr_4, s7_addr_range_4, M_ADDR_WIDTH, 7, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000f400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s7_baddr_5, s7_addr_range_5, M_ADDR_WIDTH, 7, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000f800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s7_baddr_6, s7_addr_range_6, M_ADDR_WIDTH, 7, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0000fc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s7_baddr_7, s7_addr_range_7, M_ADDR_WIDTH, 7, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s7_addr_range_0, s7_baddr_0, 7, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s7_addr_range_1, s7_baddr_1, 7, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s7_addr_range_2, s7_baddr_2, 7, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s7_addr_range_3, s7_baddr_3, 7, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s7_addr_range_4, s7_baddr_4, 7, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s7_addr_range_5, s7_baddr_5, 7, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s7_addr_range_6, s7_baddr_6, 7, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "s7_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s7 and (S7_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s7_addr_range_7, s7_baddr_7, 7, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "S7_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s7) else 'None'"
                    value_expr         = "ext_actual_base_addr(s7_baddr_0, s7_baddr_1, s7_baddr_2, s7_baddr_3, s7_baddr_4, s7_baddr_5, s7_baddr_6, s7_baddr_7, S7_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Main Settings"
                    id                 = "S7_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s7) else 'None'"
                    value_expr         = "ext_actual_base_addr(s7_addr_range_0, s7_addr_range_1, s7_addr_range_2, s7_addr_range_3, s7_addr_range_4, s7_addr_range_5, s7_addr_range_6, s7_addr_range_7, S7_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 8 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "S8_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8"
                    config_groups      = "'SystemBuilder' if(en_s8) else 'None'"
                    drc                = "ext_frag_num_drc(8, S8_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 8 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00010000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s8_baddr_0, s8_addr_range_0, M_ADDR_WIDTH, 8, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00010400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s8_baddr_1, s8_addr_range_1, M_ADDR_WIDTH, 8, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00010800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s8_baddr_2, s8_addr_range_2, M_ADDR_WIDTH, 8, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00010c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s8_baddr_3, s8_addr_range_3, M_ADDR_WIDTH, 8, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00011000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s8_baddr_4, s8_addr_range_4, M_ADDR_WIDTH, 8, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00011400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s8_baddr_5, s8_addr_range_5, M_ADDR_WIDTH, 8, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00011800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s8_baddr_6, s8_addr_range_6, M_ADDR_WIDTH, 8, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00011c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s8_baddr_7, s8_addr_range_7, M_ADDR_WIDTH, 8, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s8_addr_range_0, s8_baddr_0, 8, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s8_addr_range_1, s8_baddr_1, 8, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s8_addr_range_2, s8_baddr_2, 8, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s8_addr_range_3, s8_baddr_3, 8, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s8_addr_range_4, s8_baddr_4, 8, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s8_addr_range_5, s8_baddr_5, 8, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s8_addr_range_6, s8_baddr_6, 8, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "s8_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s8 and (S8_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s8_addr_range_7, s8_baddr_7, 8, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "S8_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s8) else 'None'"
                    value_expr         = "ext_actual_base_addr(s8_baddr_0, s8_baddr_1, s8_baddr_2, s8_baddr_3, s8_baddr_4, s8_baddr_5, s8_baddr_6, s8_baddr_7, S8_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Main Settings"
                    id                 = "S8_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s8) else 'None'"
                    value_expr         = "ext_actual_base_addr(s8_addr_range_0, s8_addr_range_1, s8_addr_range_2, s8_addr_range_3, s8_addr_range_4, s8_addr_range_5, s8_addr_range_6, s8_addr_range_7, S8_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 9 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "S9_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9"
                    config_groups      = "'SystemBuilder' if(en_s9) else 'None'"
                    drc                = "ext_frag_num_drc(9, S9_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 9 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00012000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s9_baddr_0, s9_addr_range_0, M_ADDR_WIDTH, 9, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00012400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s9_baddr_1, s9_addr_range_1, M_ADDR_WIDTH, 9, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00012800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s9_baddr_2, s9_addr_range_2, M_ADDR_WIDTH, 9, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00012c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s9_baddr_3, s9_addr_range_3, M_ADDR_WIDTH, 9, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00013000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s9_baddr_4, s9_addr_range_4, M_ADDR_WIDTH, 9, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00013400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s9_baddr_5, s9_addr_range_5, M_ADDR_WIDTH, 9, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00013800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s9_baddr_6, s9_addr_range_6, M_ADDR_WIDTH, 9, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00013c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s9_baddr_7, s9_addr_range_7, M_ADDR_WIDTH, 9, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s9_addr_range_0, s9_baddr_0, 9, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s9_addr_range_1, s9_baddr_1, 9, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s9_addr_range_2, s9_baddr_2, 9, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s9_addr_range_3, s9_baddr_3, 9, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s9_addr_range_4, s9_baddr_4, 9, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s9_addr_range_5, s9_baddr_5, 9, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s9_addr_range_6, s9_baddr_6, 9, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "s9_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s9 and (S9_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s9_addr_range_7, s9_baddr_7, 9, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "S9_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s9) else 'None'"
                    value_expr         = "ext_actual_base_addr(s9_baddr_0, s9_baddr_1, s9_baddr_2, s9_baddr_3, s9_baddr_4, s9_baddr_5, s9_baddr_6, s9_baddr_7, S9_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Main Settings"
                    id                 = "S9_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s9) else 'None'"
                    value_expr         = "ext_actual_base_addr(s9_addr_range_0, s9_addr_range_1, s9_addr_range_2, s9_addr_range_3, s9_addr_range_4, s9_addr_range_5, s9_addr_range_6, s9_addr_range_7, S9_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 10 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "S10_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10"
                    config_groups      = "'SystemBuilder' if(en_s10) else 'None'"
                    drc                = "ext_frag_num_drc(10, S10_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 10 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00014000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s10_baddr_0, s10_addr_range_0, M_ADDR_WIDTH, 10, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00014400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s10_baddr_1, s10_addr_range_1, M_ADDR_WIDTH, 10, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00014800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s10_baddr_2, s10_addr_range_2, M_ADDR_WIDTH, 10, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00014c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s10_baddr_3, s10_addr_range_3, M_ADDR_WIDTH, 10, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00015000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s10_baddr_4, s10_addr_range_4, M_ADDR_WIDTH, 10, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00015400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s10_baddr_5, s10_addr_range_5, M_ADDR_WIDTH, 10, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00015800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s10_baddr_6, s10_addr_range_6, M_ADDR_WIDTH, 10, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00015c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s10_baddr_7, s10_addr_range_7, M_ADDR_WIDTH, 10, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s10_addr_range_0, s10_baddr_0, 10, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s10_addr_range_1, s10_baddr_1, 10, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s10_addr_range_2, s10_baddr_2, 10, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s10_addr_range_3, s10_baddr_3, 10, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s10_addr_range_4, s10_baddr_4, 10, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s10_addr_range_5, s10_baddr_5, 10, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s10_addr_range_6, s10_baddr_6, 10, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "s10_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s10 and (S10_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s10_addr_range_7, s10_baddr_7, 10, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "S10_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s10) else 'None'"
                    value_expr         = "ext_actual_base_addr(s10_baddr_0, s10_baddr_1, s10_baddr_2, s10_baddr_3, s10_baddr_4, s10_baddr_5, s10_baddr_6, s10_baddr_7, S10_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Main Settings"
                    id                 = "S10_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s10) else 'None'"
                    value_expr         = "ext_actual_base_addr(s10_addr_range_0, s10_addr_range_1, s10_addr_range_2, s10_addr_range_3, s10_addr_range_4, s10_addr_range_5, s10_addr_range_6, s10_addr_range_7, S10_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 11 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "S11_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11"
                    config_groups      = "'SystemBuilder' if(en_s11) else 'None'"
                    drc                = "ext_frag_num_drc(11, S11_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 11 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00016000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s11_baddr_0, s11_addr_range_0, M_ADDR_WIDTH, 11, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00016400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s11_baddr_1, s11_addr_range_1, M_ADDR_WIDTH, 11, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00016800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s11_baddr_2, s11_addr_range_2, M_ADDR_WIDTH, 11, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00016c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s11_baddr_3, s11_addr_range_3, M_ADDR_WIDTH, 11, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00017000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s11_baddr_4, s11_addr_range_4, M_ADDR_WIDTH, 11, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00017400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s11_baddr_5, s11_addr_range_5, M_ADDR_WIDTH, 11, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00017800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s11_baddr_6, s11_addr_range_6, M_ADDR_WIDTH, 11, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00017c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s11_baddr_7, s11_addr_range_7, M_ADDR_WIDTH, 11, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s11_addr_range_0, s11_baddr_0, 11, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s11_addr_range_1, s11_baddr_1, 11, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s11_addr_range_2, s11_baddr_2, 11, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s11_addr_range_3, s11_baddr_3, 11, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s11_addr_range_4, s11_baddr_4, 11, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s11_addr_range_5, s11_baddr_5, 11, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s11_addr_range_6, s11_baddr_6, 11, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "s11_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s11 and (S11_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s11_addr_range_7, s11_baddr_7, 11, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "S11_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s11) else 'None'"
                    value_expr         = "ext_actual_base_addr(s11_baddr_0, s11_baddr_1, s11_baddr_2, s11_baddr_3, s11_baddr_4, s11_baddr_5, s11_baddr_6, s11_baddr_7, S11_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Main Settings"
                    id                 = "S11_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s11) else 'None'"
                    value_expr         = "ext_actual_base_addr(s11_addr_range_0, s11_addr_range_1, s11_addr_range_2, s11_addr_range_3, s11_addr_range_4, s11_addr_range_5, s11_addr_range_6, s11_addr_range_7, S11_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 12 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "S12_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12"
                    config_groups      = "'SystemBuilder' if(en_s12) else 'None'"
                    drc                = "ext_frag_num_drc(12, S12_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 12 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00018000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s12_baddr_0, s12_addr_range_0, M_ADDR_WIDTH, 12, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00018400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s12_baddr_1, s12_addr_range_1, M_ADDR_WIDTH, 12, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00018800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s12_baddr_2, s12_addr_range_2, M_ADDR_WIDTH, 12, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00018c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s12_baddr_3, s12_addr_range_3, M_ADDR_WIDTH, 12, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00019000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s12_baddr_4, s12_addr_range_4, M_ADDR_WIDTH, 12, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00019400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s12_baddr_5, s12_addr_range_5, M_ADDR_WIDTH, 12, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00019800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s12_baddr_6, s12_addr_range_6, M_ADDR_WIDTH, 12, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00019c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s12_baddr_7, s12_addr_range_7, M_ADDR_WIDTH, 12, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s12_addr_range_0, s12_baddr_0, 12, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s12_addr_range_1, s12_baddr_1, 12, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s12_addr_range_2, s12_baddr_2, 12, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s12_addr_range_3, s12_baddr_3, 12, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s12_addr_range_4, s12_baddr_4, 12, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s12_addr_range_5, s12_baddr_5, 12, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s12_addr_range_6, s12_baddr_6, 12, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "s12_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s12 and (S12_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s12_addr_range_7, s12_baddr_7, 12, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "S12_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s12) else 'None'"
                    value_expr         = "ext_actual_base_addr(s12_baddr_0, s12_baddr_1, s12_baddr_2, s12_baddr_3, s12_baddr_4, s12_baddr_5, s12_baddr_6, s12_baddr_7, S12_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Main Settings"
                    id                 = "S12_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s12) else 'None'"
                    value_expr         = "ext_actual_base_addr(s12_addr_range_0, s12_addr_range_1, s12_addr_range_2, s12_addr_range_3, s12_addr_range_4, s12_addr_range_5, s12_addr_range_6, s12_addr_range_7, S12_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 13 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "S13_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13"
                    config_groups      = "'SystemBuilder' if(en_s13) else 'None'"
                    drc                = "ext_frag_num_drc(13, S13_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 13 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001a000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s13_baddr_0, s13_addr_range_0, M_ADDR_WIDTH, 13, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001a400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s13_baddr_1, s13_addr_range_1, M_ADDR_WIDTH, 13, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001a800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s13_baddr_2, s13_addr_range_2, M_ADDR_WIDTH, 13, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001ac00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s13_baddr_3, s13_addr_range_3, M_ADDR_WIDTH, 13, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001b000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s13_baddr_4, s13_addr_range_4, M_ADDR_WIDTH, 13, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001b400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s13_baddr_5, s13_addr_range_5, M_ADDR_WIDTH, 13, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001b800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s13_baddr_6, s13_addr_range_6, M_ADDR_WIDTH, 13, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001bc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s13_baddr_7, s13_addr_range_7, M_ADDR_WIDTH, 13, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s13_addr_range_0, s13_baddr_0, 13, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s13_addr_range_1, s13_baddr_1, 13, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s13_addr_range_2, s13_baddr_2, 13, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s13_addr_range_3, s13_baddr_3, 13, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s13_addr_range_4, s13_baddr_4, 13, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s13_addr_range_5, s13_baddr_5, 13, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s13_addr_range_6, s13_baddr_6, 13, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "s13_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s13 and (S13_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s13_addr_range_7, s13_baddr_7, 13, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "S13_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s13) else 'None'"
                    value_expr         = "ext_actual_base_addr(s13_baddr_0, s13_baddr_1, s13_baddr_2, s13_baddr_3, s13_baddr_4, s13_baddr_5, s13_baddr_6, s13_baddr_7, S13_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Main Settings"
                    id                 = "S13_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s13) else 'None'"
                    value_expr         = "ext_actual_base_addr(s13_addr_range_0, s13_addr_range_1, s13_addr_range_2, s13_addr_range_3, s13_addr_range_4, s13_addr_range_5, s13_addr_range_6, s13_addr_range_7, S13_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 14 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "S14_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14"
                    config_groups      = "'SystemBuilder' if(en_s14) else 'None'"
                    drc                = "ext_frag_num_drc(14, S14_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 14 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001c000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s14_baddr_0, s14_addr_range_0, M_ADDR_WIDTH, 14, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001c400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s14_baddr_1, s14_addr_range_1, M_ADDR_WIDTH, 14, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001c800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s14_baddr_2, s14_addr_range_2, M_ADDR_WIDTH, 14, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001cc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s14_baddr_3, s14_addr_range_3, M_ADDR_WIDTH, 14, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001d000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s14_baddr_4, s14_addr_range_4, M_ADDR_WIDTH, 14, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001d400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s14_baddr_5, s14_addr_range_5, M_ADDR_WIDTH, 14, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001d800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s14_baddr_6, s14_addr_range_6, M_ADDR_WIDTH, 14, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001dc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s14_baddr_7, s14_addr_range_7, M_ADDR_WIDTH, 14, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s14_addr_range_0, s14_baddr_0, 14, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s14_addr_range_1, s14_baddr_1, 14, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s14_addr_range_2, s14_baddr_2, 14, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s14_addr_range_3, s14_baddr_3, 14, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s14_addr_range_4, s14_baddr_4, 14, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s14_addr_range_5, s14_baddr_5, 14, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s14_addr_range_6, s14_baddr_6, 14, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "s14_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s14 and (S14_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s14_addr_range_7, s14_baddr_7, 14, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "S14_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s14) else 'None'"
                    value_expr         = "ext_actual_base_addr(s14_baddr_0, s14_baddr_1, s14_baddr_2, s14_baddr_3, s14_baddr_4, s14_baddr_5, s14_baddr_6, s14_baddr_7, S14_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Main Settings"
                    id                 = "S14_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s14) else 'None'"
                    value_expr         = "ext_actual_base_addr(s14_addr_range_0, s14_addr_range_1, s14_addr_range_2, s14_addr_range_3, s14_addr_range_4, s14_addr_range_5, s14_addr_range_6, s14_addr_range_7, S14_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 15 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "S15_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15"
                    config_groups      = "'SystemBuilder' if(en_s15) else 'None'"
                    drc                = "ext_frag_num_drc(15, S15_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 15 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001e000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s15_baddr_0, s15_addr_range_0, M_ADDR_WIDTH, 15, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001e400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s15_baddr_1, s15_addr_range_1, M_ADDR_WIDTH, 15, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001e800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s15_baddr_2, s15_addr_range_2, M_ADDR_WIDTH, 15, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001ec00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s15_baddr_3, s15_addr_range_3, M_ADDR_WIDTH, 15, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001f000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s15_baddr_4, s15_addr_range_4, M_ADDR_WIDTH, 15, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001f400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s15_baddr_5, s15_addr_range_5, M_ADDR_WIDTH, 15, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001f800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s15_baddr_6, s15_addr_range_6, M_ADDR_WIDTH, 15, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0001fc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s15_baddr_7, s15_addr_range_7, M_ADDR_WIDTH, 15, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s15_addr_range_0, s15_baddr_0, 15, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s15_addr_range_1, s15_baddr_1, 15, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s15_addr_range_2, s15_baddr_2, 15, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s15_addr_range_3, s15_baddr_3, 15, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s15_addr_range_4, s15_baddr_4, 15, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s15_addr_range_5, s15_baddr_5, 15, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s15_addr_range_6, s15_baddr_6, 15, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "s15_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s15 and (S15_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s15_addr_range_7, s15_baddr_7, 15, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "S15_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s15) else 'None'"
                    value_expr         = "ext_actual_base_addr(s15_baddr_0, s15_baddr_1, s15_baddr_2, s15_baddr_3, s15_baddr_4, s15_baddr_5, s15_baddr_6, s15_baddr_7, S15_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Main Settings"
                    id                 = "S15_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s15) else 'None'"
                    value_expr         = "ext_actual_base_addr(s15_addr_range_0, s15_addr_range_1, s15_addr_range_2, s15_addr_range_3, s15_addr_range_4, s15_addr_range_5, s15_addr_range_6, s15_addr_range_7, S15_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 16 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "S16_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16"
                    config_groups      = "'SystemBuilder' if(en_s16) else 'None'"
                    drc                = "ext_frag_num_drc(16, S16_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 16 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00020000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s16_baddr_0, s16_addr_range_0, M_ADDR_WIDTH, 16, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00020400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s16_baddr_1, s16_addr_range_1, M_ADDR_WIDTH, 16, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00020800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s16_baddr_2, s16_addr_range_2, M_ADDR_WIDTH, 16, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00020c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s16_baddr_3, s16_addr_range_3, M_ADDR_WIDTH, 16, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00021000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s16_baddr_4, s16_addr_range_4, M_ADDR_WIDTH, 16, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00021400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s16_baddr_5, s16_addr_range_5, M_ADDR_WIDTH, 16, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00021800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s16_baddr_6, s16_addr_range_6, M_ADDR_WIDTH, 16, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00021c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s16_baddr_7, s16_addr_range_7, M_ADDR_WIDTH, 16, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s16_addr_range_0, s16_baddr_0, 16, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s16_addr_range_1, s16_baddr_1, 16, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s16_addr_range_2, s16_baddr_2, 16, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s16_addr_range_3, s16_baddr_3, 16, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s16_addr_range_4, s16_baddr_4, 16, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s16_addr_range_5, s16_baddr_5, 16, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s16_addr_range_6, s16_baddr_6, 16, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "s16_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s16 and (S16_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s16_addr_range_7, s16_baddr_7, 16, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "S16_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s16) else 'None'"
                    value_expr         = "ext_actual_base_addr(s16_baddr_0, s16_baddr_1, s16_baddr_2, s16_baddr_3, s16_baddr_4, s16_baddr_5, s16_baddr_6, s16_baddr_7, S16_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Main Settings"
                    id                 = "S16_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s16) else 'None'"
                    value_expr         = "ext_actual_base_addr(s16_addr_range_0, s16_addr_range_1, s16_addr_range_2, s16_addr_range_3, s16_addr_range_4, s16_addr_range_5, s16_addr_range_6, s16_addr_range_7, S16_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 17 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "S17_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17"
                    config_groups      = "'SystemBuilder' if(en_s17) else 'None'"
                    drc                = "ext_frag_num_drc(17, S17_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 17 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00022000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s17_baddr_0, s17_addr_range_0, M_ADDR_WIDTH, 17, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00022400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s17_baddr_1, s17_addr_range_1, M_ADDR_WIDTH, 17, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00022800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s17_baddr_2, s17_addr_range_2, M_ADDR_WIDTH, 17, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00022c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s17_baddr_3, s17_addr_range_3, M_ADDR_WIDTH, 17, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00023000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s17_baddr_4, s17_addr_range_4, M_ADDR_WIDTH, 17, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00023400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s17_baddr_5, s17_addr_range_5, M_ADDR_WIDTH, 17, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00023800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s17_baddr_6, s17_addr_range_6, M_ADDR_WIDTH, 17, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00023c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s17_baddr_7, s17_addr_range_7, M_ADDR_WIDTH, 17, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s17_addr_range_0, s17_baddr_0, 17, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s17_addr_range_1, s17_baddr_1, 17, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s17_addr_range_2, s17_baddr_2, 17, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s17_addr_range_3, s17_baddr_3, 17, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s17_addr_range_4, s17_baddr_4, 17, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s17_addr_range_5, s17_baddr_5, 17, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s17_addr_range_6, s17_baddr_6, 17, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "s17_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s17 and (S17_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s17_addr_range_7, s17_baddr_7, 17, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "S17_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s17) else 'None'"
                    value_expr         = "ext_actual_base_addr(s17_baddr_0, s17_baddr_1, s17_baddr_2, s17_baddr_3, s17_baddr_4, s17_baddr_5, s17_baddr_6, s17_baddr_7, S17_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Main Settings"
                    id                 = "S17_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s17) else 'None'"
                    value_expr         = "ext_actual_base_addr(s17_addr_range_0, s17_addr_range_1, s17_addr_range_2, s17_addr_range_3, s17_addr_range_4, s17_addr_range_5, s17_addr_range_6, s17_addr_range_7, S17_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 18 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "S18_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18"
                    config_groups      = "'SystemBuilder' if(en_s18) else 'None'"
                    drc                = "ext_frag_num_drc(18, S18_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 18 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00024000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s18_baddr_0, s18_addr_range_0, M_ADDR_WIDTH, 18, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00024400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s18_baddr_1, s18_addr_range_1, M_ADDR_WIDTH, 18, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00024800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s18_baddr_2, s18_addr_range_2, M_ADDR_WIDTH, 18, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00024c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s18_baddr_3, s18_addr_range_3, M_ADDR_WIDTH, 18, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00025000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s18_baddr_4, s18_addr_range_4, M_ADDR_WIDTH, 18, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00025400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s18_baddr_5, s18_addr_range_5, M_ADDR_WIDTH, 18, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00025800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s18_baddr_6, s18_addr_range_6, M_ADDR_WIDTH, 18, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00025c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s18_baddr_7, s18_addr_range_7, M_ADDR_WIDTH, 18, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s18_addr_range_0, s18_baddr_0, 18, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s18_addr_range_1, s18_baddr_1, 18, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s18_addr_range_2, s18_baddr_2, 18, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s18_addr_range_3, s18_baddr_3, 18, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s18_addr_range_4, s18_baddr_4, 18, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s18_addr_range_5, s18_baddr_5, 18, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s18_addr_range_6, s18_baddr_6, 18, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "s18_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s18 and (S18_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s18_addr_range_7, s18_baddr_7, 18, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "S18_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s18) else 'None'"
                    value_expr         = "ext_actual_base_addr(s18_baddr_0, s18_baddr_1, s18_baddr_2, s18_baddr_3, s18_baddr_4, s18_baddr_5, s18_baddr_6, s18_baddr_7, S18_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Main Settings"
                    id                 = "S18_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s18) else 'None'"
                    value_expr         = "ext_actual_base_addr(s18_addr_range_0, s18_addr_range_1, s18_addr_range_2, s18_addr_range_3, s18_addr_range_4, s18_addr_range_5, s18_addr_range_6, s18_addr_range_7, S18_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 19 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "S19_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19"
                    config_groups      = "'SystemBuilder' if(en_s19) else 'None'"
                    drc                = "ext_frag_num_drc(19, S19_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 19 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00026000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s19_baddr_0, s19_addr_range_0, M_ADDR_WIDTH, 19, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00026400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s19_baddr_1, s19_addr_range_1, M_ADDR_WIDTH, 19, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00026800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s19_baddr_2, s19_addr_range_2, M_ADDR_WIDTH, 19, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00026c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s19_baddr_3, s19_addr_range_3, M_ADDR_WIDTH, 19, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00027000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s19_baddr_4, s19_addr_range_4, M_ADDR_WIDTH, 19, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00027400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s19_baddr_5, s19_addr_range_5, M_ADDR_WIDTH, 19, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00027800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s19_baddr_6, s19_addr_range_6, M_ADDR_WIDTH, 19, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00027c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s19_baddr_7, s19_addr_range_7, M_ADDR_WIDTH, 19, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s19_addr_range_0, s19_baddr_0, 19, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s19_addr_range_1, s19_baddr_1, 19, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s19_addr_range_2, s19_baddr_2, 19, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s19_addr_range_3, s19_baddr_3, 19, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s19_addr_range_4, s19_baddr_4, 19, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s19_addr_range_5, s19_baddr_5, 19, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s19_addr_range_6, s19_baddr_6, 19, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "s19_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s19 and (S19_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s19_addr_range_7, s19_baddr_7, 19, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "S19_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s19) else 'None'"
                    value_expr         = "ext_actual_base_addr(s19_baddr_0, s19_baddr_1, s19_baddr_2, s19_baddr_3, s19_baddr_4, s19_baddr_5, s19_baddr_6, s19_baddr_7, S19_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Main Settings"
                    id                 = "S19_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s19) else 'None'"
                    value_expr         = "ext_actual_base_addr(s19_addr_range_0, s19_addr_range_1, s19_addr_range_2, s19_addr_range_3, s19_addr_range_4, s19_addr_range_5, s19_addr_range_6, s19_addr_range_7, S19_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 20 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "S20_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20"
                    config_groups      = "'SystemBuilder' if(en_s20) else 'None'"
                    drc                = "ext_frag_num_drc(20, S20_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 20 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00028000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s20_baddr_0, s20_addr_range_0, M_ADDR_WIDTH, 20, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00028400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s20_baddr_1, s20_addr_range_1, M_ADDR_WIDTH, 20, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00028800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s20_baddr_2, s20_addr_range_2, M_ADDR_WIDTH, 20, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00028c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s20_baddr_3, s20_addr_range_3, M_ADDR_WIDTH, 20, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00029000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s20_baddr_4, s20_addr_range_4, M_ADDR_WIDTH, 20, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00029400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s20_baddr_5, s20_addr_range_5, M_ADDR_WIDTH, 20, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00029800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s20_baddr_6, s20_addr_range_6, M_ADDR_WIDTH, 20, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00029c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s20_baddr_7, s20_addr_range_7, M_ADDR_WIDTH, 20, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s20_addr_range_0, s20_baddr_0, 20, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s20_addr_range_1, s20_baddr_1, 20, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s20_addr_range_2, s20_baddr_2, 20, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s20_addr_range_3, s20_baddr_3, 20, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s20_addr_range_4, s20_baddr_4, 20, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s20_addr_range_5, s20_baddr_5, 20, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s20_addr_range_6, s20_baddr_6, 20, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "s20_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s20 and (S20_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s20_addr_range_7, s20_baddr_7, 20, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "S20_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s20) else 'None'"
                    value_expr         = "ext_actual_base_addr(s20_baddr_0, s20_baddr_1, s20_baddr_2, s20_baddr_3, s20_baddr_4, s20_baddr_5, s20_baddr_6, s20_baddr_7, S20_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Main Settings"
                    id                 = "S20_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s20) else 'None'"
                    value_expr         = "ext_actual_base_addr(s20_addr_range_0, s20_addr_range_1, s20_addr_range_2, s20_addr_range_3, s20_addr_range_4, s20_addr_range_5, s20_addr_range_6, s20_addr_range_7, S20_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 21 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "S21_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21"
                    config_groups      = "'SystemBuilder' if(en_s21) else 'None'"
                    drc                = "ext_frag_num_drc(21, S21_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 21 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002a000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s21_baddr_0, s21_addr_range_0, M_ADDR_WIDTH, 21, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002a400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s21_baddr_1, s21_addr_range_1, M_ADDR_WIDTH, 21, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002a800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s21_baddr_2, s21_addr_range_2, M_ADDR_WIDTH, 21, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002ac00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s21_baddr_3, s21_addr_range_3, M_ADDR_WIDTH, 21, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002b000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s21_baddr_4, s21_addr_range_4, M_ADDR_WIDTH, 21, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002b400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s21_baddr_5, s21_addr_range_5, M_ADDR_WIDTH, 21, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002b800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s21_baddr_6, s21_addr_range_6, M_ADDR_WIDTH, 21, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002bc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s21_baddr_7, s21_addr_range_7, M_ADDR_WIDTH, 21, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s21_addr_range_0, s21_baddr_0, 21, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s21_addr_range_1, s21_baddr_1, 21, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s21_addr_range_2, s21_baddr_2, 21, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s21_addr_range_3, s21_baddr_3, 21, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s21_addr_range_4, s21_baddr_4, 21, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s21_addr_range_5, s21_baddr_5, 21, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s21_addr_range_6, s21_baddr_6, 21, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "s21_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s21 and (S21_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s21_addr_range_7, s21_baddr_7, 21, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "S21_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s21) else 'None'"
                    value_expr         = "ext_actual_base_addr(s21_baddr_0, s21_baddr_1, s21_baddr_2, s21_baddr_3, s21_baddr_4, s21_baddr_5, s21_baddr_6, s21_baddr_7, S21_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Main Settings"
                    id                 = "S21_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s21) else 'None'"
                    value_expr         = "ext_actual_base_addr(s21_addr_range_0, s21_addr_range_1, s21_addr_range_2, s21_addr_range_3, s21_addr_range_4, s21_addr_range_5, s21_addr_range_6, s21_addr_range_7, S21_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 22 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "S22_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22"
                    config_groups      = "'SystemBuilder' if(en_s22) else 'None'"
                    drc                = "ext_frag_num_drc(22, S22_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 22 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002c000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s22_baddr_0, s22_addr_range_0, M_ADDR_WIDTH, 22, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002c400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s22_baddr_1, s22_addr_range_1, M_ADDR_WIDTH, 22, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002c800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s22_baddr_2, s22_addr_range_2, M_ADDR_WIDTH, 22, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002cc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s22_baddr_3, s22_addr_range_3, M_ADDR_WIDTH, 22, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002d000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s22_baddr_4, s22_addr_range_4, M_ADDR_WIDTH, 22, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002d400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s22_baddr_5, s22_addr_range_5, M_ADDR_WIDTH, 22, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002d800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s22_baddr_6, s22_addr_range_6, M_ADDR_WIDTH, 22, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002dc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s22_baddr_7, s22_addr_range_7, M_ADDR_WIDTH, 22, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s22_addr_range_0, s22_baddr_0, 22, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s22_addr_range_1, s22_baddr_1, 22, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s22_addr_range_2, s22_baddr_2, 22, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s22_addr_range_3, s22_baddr_3, 22, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s22_addr_range_4, s22_baddr_4, 22, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s22_addr_range_5, s22_baddr_5, 22, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s22_addr_range_6, s22_baddr_6, 22, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "s22_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s22 and (S22_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s22_addr_range_7, s22_baddr_7, 22, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "S22_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s22) else 'None'"
                    value_expr         = "ext_actual_base_addr(s22_baddr_0, s22_baddr_1, s22_baddr_2, s22_baddr_3, s22_baddr_4, s22_baddr_5, s22_baddr_6, s22_baddr_7, S22_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Main Settings"
                    id                 = "S22_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s22) else 'None'"
                    value_expr         = "ext_actual_base_addr(s22_addr_range_0, s22_addr_range_1, s22_addr_range_2, s22_addr_range_3, s22_addr_range_4, s22_addr_range_5, s22_addr_range_6, s22_addr_range_7, S22_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 23 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "S23_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23"
                    config_groups      = "'SystemBuilder' if(en_s23) else 'None'"
                    drc                = "ext_frag_num_drc(23, S23_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 23 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002e000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s23_baddr_0, s23_addr_range_0, M_ADDR_WIDTH, 23, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002e400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s23_baddr_1, s23_addr_range_1, M_ADDR_WIDTH, 23, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002e800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s23_baddr_2, s23_addr_range_2, M_ADDR_WIDTH, 23, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002ec00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s23_baddr_3, s23_addr_range_3, M_ADDR_WIDTH, 23, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002f000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s23_baddr_4, s23_addr_range_4, M_ADDR_WIDTH, 23, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002f400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s23_baddr_5, s23_addr_range_5, M_ADDR_WIDTH, 23, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002f800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s23_baddr_6, s23_addr_range_6, M_ADDR_WIDTH, 23, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0002fc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s23_baddr_7, s23_addr_range_7, M_ADDR_WIDTH, 23, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s23_addr_range_0, s23_baddr_0, 23, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s23_addr_range_1, s23_baddr_1, 23, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s23_addr_range_2, s23_baddr_2, 23, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s23_addr_range_3, s23_baddr_3, 23, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s23_addr_range_4, s23_baddr_4, 23, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s23_addr_range_5, s23_baddr_5, 23, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s23_addr_range_6, s23_baddr_6, 23, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "s23_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s23 and (S23_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s23_addr_range_7, s23_baddr_7, 23, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "S23_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s23) else 'None'"
                    value_expr         = "ext_actual_base_addr(s23_baddr_0, s23_baddr_1, s23_baddr_2, s23_baddr_3, s23_baddr_4, s23_baddr_5, s23_baddr_6, s23_baddr_7, S23_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Main Settings"
                    id                 = "S23_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s23) else 'None'"
                    value_expr         = "ext_actual_base_addr(s23_addr_range_0, s23_addr_range_1, s23_addr_range_2, s23_addr_range_3, s23_addr_range_4, s23_addr_range_5, s23_addr_range_6, s23_addr_range_7, S23_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 24 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "S24_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24"
                    config_groups      = "'SystemBuilder' if(en_s24) else 'None'"
                    drc                = "ext_frag_num_drc(24, S24_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 24 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00030000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s24_baddr_0, s24_addr_range_0, M_ADDR_WIDTH, 24, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00030400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s24_baddr_1, s24_addr_range_1, M_ADDR_WIDTH, 24, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00030800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s24_baddr_2, s24_addr_range_2, M_ADDR_WIDTH, 24, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00030c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s24_baddr_3, s24_addr_range_3, M_ADDR_WIDTH, 24, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00031000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s24_baddr_4, s24_addr_range_4, M_ADDR_WIDTH, 24, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00031400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s24_baddr_5, s24_addr_range_5, M_ADDR_WIDTH, 24, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00031800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s24_baddr_6, s24_addr_range_6, M_ADDR_WIDTH, 24, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00031c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s24_baddr_7, s24_addr_range_7, M_ADDR_WIDTH, 24, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s24_addr_range_0, s24_baddr_0, 24, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s24_addr_range_1, s24_baddr_1, 24, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s24_addr_range_2, s24_baddr_2, 24, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s24_addr_range_3, s24_baddr_3, 24, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s24_addr_range_4, s24_baddr_4, 24, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s24_addr_range_5, s24_baddr_5, 24, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s24_addr_range_6, s24_baddr_6, 24, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "s24_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s24 and (S24_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s24_addr_range_7, s24_baddr_7, 24, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "S24_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s24) else 'None'"
                    value_expr         = "ext_actual_base_addr(s24_baddr_0, s24_baddr_1, s24_baddr_2, s24_baddr_3, s24_baddr_4, s24_baddr_5, s24_baddr_6, s24_baddr_7, S24_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Main Settings"
                    id                 = "S24_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s24) else 'None'"
                    value_expr         = "ext_actual_base_addr(s24_addr_range_0, s24_addr_range_1, s24_addr_range_2, s24_addr_range_3, s24_addr_range_4, s24_addr_range_5, s24_addr_range_6, s24_addr_range_7, S24_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 25 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "S25_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25"
                    config_groups      = "'SystemBuilder' if(en_s25) else 'None'"
                    drc                = "ext_frag_num_drc(25, S25_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 25 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00032000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s25_baddr_0, s25_addr_range_0, M_ADDR_WIDTH, 25, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00032400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s25_baddr_1, s25_addr_range_1, M_ADDR_WIDTH, 25, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00032800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s25_baddr_2, s25_addr_range_2, M_ADDR_WIDTH, 25, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00032c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s25_baddr_3, s25_addr_range_3, M_ADDR_WIDTH, 25, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00033000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s25_baddr_4, s25_addr_range_4, M_ADDR_WIDTH, 25, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00033400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s25_baddr_5, s25_addr_range_5, M_ADDR_WIDTH, 25, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00033800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s25_baddr_6, s25_addr_range_6, M_ADDR_WIDTH, 25, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00033c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s25_baddr_7, s25_addr_range_7, M_ADDR_WIDTH, 25, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s25_addr_range_0, s25_baddr_0, 25, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s25_addr_range_1, s25_baddr_1, 25, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s25_addr_range_2, s25_baddr_2, 25, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s25_addr_range_3, s25_baddr_3, 25, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s25_addr_range_4, s25_baddr_4, 25, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s25_addr_range_5, s25_baddr_5, 25, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s25_addr_range_6, s25_baddr_6, 25, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "s25_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s25 and (S25_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s25_addr_range_7, s25_baddr_7, 25, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "S25_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s25) else 'None'"
                    value_expr         = "ext_actual_base_addr(s25_baddr_0, s25_baddr_1, s25_baddr_2, s25_baddr_3, s25_baddr_4, s25_baddr_5, s25_baddr_6, s25_baddr_7, S25_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Main Settings"
                    id                 = "S25_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s25) else 'None'"
                    value_expr         = "ext_actual_base_addr(s25_addr_range_0, s25_addr_range_1, s25_addr_range_2, s25_addr_range_3, s25_addr_range_4, s25_addr_range_5, s25_addr_range_6, s25_addr_range_7, S25_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 26 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "S26_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26"
                    config_groups      = "'SystemBuilder' if(en_s26) else 'None'"
                    drc                = "ext_frag_num_drc(26, S26_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 26 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00034000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s26_baddr_0, s26_addr_range_0, M_ADDR_WIDTH, 26, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00034400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s26_baddr_1, s26_addr_range_1, M_ADDR_WIDTH, 26, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00034800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s26_baddr_2, s26_addr_range_2, M_ADDR_WIDTH, 26, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00034c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s26_baddr_3, s26_addr_range_3, M_ADDR_WIDTH, 26, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00035000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s26_baddr_4, s26_addr_range_4, M_ADDR_WIDTH, 26, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00035400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s26_baddr_5, s26_addr_range_5, M_ADDR_WIDTH, 26, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00035800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s26_baddr_6, s26_addr_range_6, M_ADDR_WIDTH, 26, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00035c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s26_baddr_7, s26_addr_range_7, M_ADDR_WIDTH, 26, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s26_addr_range_0, s26_baddr_0, 26, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s26_addr_range_1, s26_baddr_1, 26, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s26_addr_range_2, s26_baddr_2, 26, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s26_addr_range_3, s26_baddr_3, 26, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s26_addr_range_4, s26_baddr_4, 26, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s26_addr_range_5, s26_baddr_5, 26, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s26_addr_range_6, s26_baddr_6, 26, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "s26_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s26 and (S26_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s26_addr_range_7, s26_baddr_7, 26, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "S26_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s26) else 'None'"
                    value_expr         = "ext_actual_base_addr(s26_baddr_0, s26_baddr_1, s26_baddr_2, s26_baddr_3, s26_baddr_4, s26_baddr_5, s26_baddr_6, s26_baddr_7, S26_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Main Settings"
                    id                 = "S26_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s26) else 'None'"
                    value_expr         = "ext_actual_base_addr(s26_addr_range_0, s26_addr_range_1, s26_addr_range_2, s26_addr_range_3, s26_addr_range_4, s26_addr_range_5, s26_addr_range_6, s26_addr_range_7, S26_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 27 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "S27_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27"
                    config_groups      = "'SystemBuilder' if(en_s27) else 'None'"
                    drc                = "ext_frag_num_drc(27, S27_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 27 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00036000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s27_baddr_0, s27_addr_range_0, M_ADDR_WIDTH, 27, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00036400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s27_baddr_1, s27_addr_range_1, M_ADDR_WIDTH, 27, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00036800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s27_baddr_2, s27_addr_range_2, M_ADDR_WIDTH, 27, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00036c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s27_baddr_3, s27_addr_range_3, M_ADDR_WIDTH, 27, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00037000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s27_baddr_4, s27_addr_range_4, M_ADDR_WIDTH, 27, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00037400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s27_baddr_5, s27_addr_range_5, M_ADDR_WIDTH, 27, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00037800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s27_baddr_6, s27_addr_range_6, M_ADDR_WIDTH, 27, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00037c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s27_baddr_7, s27_addr_range_7, M_ADDR_WIDTH, 27, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s27_addr_range_0, s27_baddr_0, 27, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s27_addr_range_1, s27_baddr_1, 27, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s27_addr_range_2, s27_baddr_2, 27, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s27_addr_range_3, s27_baddr_3, 27, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s27_addr_range_4, s27_baddr_4, 27, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s27_addr_range_5, s27_baddr_5, 27, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s27_addr_range_6, s27_baddr_6, 27, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "s27_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s27 and (S27_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s27_addr_range_7, s27_baddr_7, 27, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "S27_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s27) else 'None'"
                    value_expr         = "ext_actual_base_addr(s27_baddr_0, s27_baddr_1, s27_baddr_2, s27_baddr_3, s27_baddr_4, s27_baddr_5, s27_baddr_6, s27_baddr_7, S27_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Main Settings"
                    id                 = "S27_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s27) else 'None'"
                    value_expr         = "ext_actual_base_addr(s27_addr_range_0, s27_addr_range_1, s27_addr_range_2, s27_addr_range_3, s27_addr_range_4, s27_addr_range_5, s27_addr_range_6, s27_addr_range_7, S27_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 28 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "S28_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28"
                    config_groups      = "'SystemBuilder' if(en_s28) else 'None'"
                    drc                = "ext_frag_num_drc(28, S28_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 28 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "00038000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s28_baddr_0, s28_addr_range_0, M_ADDR_WIDTH, 28, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "00038400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s28_baddr_1, s28_addr_range_1, M_ADDR_WIDTH, 28, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "00038800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s28_baddr_2, s28_addr_range_2, M_ADDR_WIDTH, 28, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "00038c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s28_baddr_3, s28_addr_range_3, M_ADDR_WIDTH, 28, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "00039000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s28_baddr_4, s28_addr_range_4, M_ADDR_WIDTH, 28, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "00039400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s28_baddr_5, s28_addr_range_5, M_ADDR_WIDTH, 28, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "00039800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s28_baddr_6, s28_addr_range_6, M_ADDR_WIDTH, 28, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "00039c00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s28_baddr_7, s28_addr_range_7, M_ADDR_WIDTH, 28, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s28_addr_range_0, s28_baddr_0, 28, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s28_addr_range_1, s28_baddr_1, 28, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s28_addr_range_2, s28_baddr_2, 28, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s28_addr_range_3, s28_baddr_3, 28, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s28_addr_range_4, s28_baddr_4, 28, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s28_addr_range_5, s28_baddr_5, 28, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s28_addr_range_6, s28_baddr_6, 28, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "s28_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s28 and (S28_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s28_addr_range_7, s28_baddr_7, 28, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "S28_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s28) else 'None'"
                    value_expr         = "ext_actual_base_addr(s28_baddr_0, s28_baddr_1, s28_baddr_2, s28_baddr_3, s28_baddr_4, s28_baddr_5, s28_baddr_6, s28_baddr_7, S28_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Main Settings"
                    id                 = "S28_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s28) else 'None'"
                    value_expr         = "ext_actual_base_addr(s28_addr_range_0, s28_addr_range_1, s28_addr_range_2, s28_addr_range_3, s28_addr_range_4, s28_addr_range_5, s28_addr_range_6, s28_addr_range_7, S28_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 29 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "S29_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29"
                    config_groups      = "'SystemBuilder' if(en_s29) else 'None'"
                    drc                = "ext_frag_num_drc(29, S29_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 29 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003a000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s29_baddr_0, s29_addr_range_0, M_ADDR_WIDTH, 29, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003a400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s29_baddr_1, s29_addr_range_1, M_ADDR_WIDTH, 29, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003a800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s29_baddr_2, s29_addr_range_2, M_ADDR_WIDTH, 29, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003ac00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s29_baddr_3, s29_addr_range_3, M_ADDR_WIDTH, 29, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003b000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s29_baddr_4, s29_addr_range_4, M_ADDR_WIDTH, 29, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003b400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s29_baddr_5, s29_addr_range_5, M_ADDR_WIDTH, 29, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003b800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s29_baddr_6, s29_addr_range_6, M_ADDR_WIDTH, 29, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003bc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s29_baddr_7, s29_addr_range_7, M_ADDR_WIDTH, 29, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s29_addr_range_0, s29_baddr_0, 29, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s29_addr_range_1, s29_baddr_1, 29, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s29_addr_range_2, s29_baddr_2, 29, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s29_addr_range_3, s29_baddr_3, 29, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s29_addr_range_4, s29_baddr_4, 29, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s29_addr_range_5, s29_baddr_5, 29, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s29_addr_range_6, s29_baddr_6, 29, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "s29_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s29 and (S29_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s29_addr_range_7, s29_baddr_7, 29, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "S29_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s29) else 'None'"
                    value_expr         = "ext_actual_base_addr(s29_baddr_0, s29_baddr_1, s29_baddr_2, s29_baddr_3, s29_baddr_4, s29_baddr_5, s29_baddr_6, s29_baddr_7, S29_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Main Settings"
                    id                 = "S29_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s29) else 'None'"
                    value_expr         = "ext_actual_base_addr(s29_addr_range_0, s29_addr_range_1, s29_addr_range_2, s29_addr_range_3, s29_addr_range_4, s29_addr_range_5, s29_addr_range_6, s29_addr_range_7, S29_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 30 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "S30_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30"
                    config_groups      = "'SystemBuilder' if(en_s30) else 'None'"
                    drc                = "ext_frag_num_drc(30, S30_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 30 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003c000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s30_baddr_0, s30_addr_range_0, M_ADDR_WIDTH, 30, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003c400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s30_baddr_1, s30_addr_range_1, M_ADDR_WIDTH, 30, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003c800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s30_baddr_2, s30_addr_range_2, M_ADDR_WIDTH, 30, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003cc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s30_baddr_3, s30_addr_range_3, M_ADDR_WIDTH, 30, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003d000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s30_baddr_4, s30_addr_range_4, M_ADDR_WIDTH, 30, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003d400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s30_baddr_5, s30_addr_range_5, M_ADDR_WIDTH, 30, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003d800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s30_baddr_6, s30_addr_range_6, M_ADDR_WIDTH, 30, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003dc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s30_baddr_7, s30_addr_range_7, M_ADDR_WIDTH, 30, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s30_addr_range_0, s30_baddr_0, 30, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s30_addr_range_1, s30_baddr_1, 30, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s30_addr_range_2, s30_baddr_2, 30, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s30_addr_range_3, s30_baddr_3, 30, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s30_addr_range_4, s30_baddr_4, 30, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s30_addr_range_5, s30_baddr_5, 30, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s30_addr_range_6, s30_baddr_6, 30, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "s30_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s30 and (S30_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s30_addr_range_7, s30_baddr_7, 30, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "S30_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s30) else 'None'"
                    value_expr         = "ext_actual_base_addr(s30_baddr_0, s30_baddr_1, s30_baddr_2, s30_baddr_3, s30_baddr_4, s30_baddr_5, s30_baddr_6, s30_baddr_7, S30_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Main Settings"
                    id                 = "S30_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s30) else 'None'"
                    value_expr         = "ext_actual_base_addr(s30_addr_range_0, s30_addr_range_1, s30_addr_range_2, s30_addr_range_3, s30_addr_range_4, s30_addr_range_5, s30_addr_range_6, s30_addr_range_7, S30_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
  <!-- Subordinate 31 Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "S31_FRAGMENT_EN"
                    type               = "param"
                    value_type         = "int"
                    default            = "1"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31"
                    config_groups      = "'SystemBuilder' if(en_s31) else 'None'"
                    drc                = "ext_frag_num_drc(31, S31_FRAGMENT_EN)"
                    options            = "range(1,9)"
    />
    <!-- Subordinate 31 Address Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003e000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 0)"
                    drc                = "ext_base_addr_drc(s31_baddr_0, s31_addr_range_0, M_ADDR_WIDTH, 31, 0)"
                    title              = "Base Address 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003e400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 1)"
                    drc                = "ext_base_addr_drc(s31_baddr_1, s31_addr_range_1, M_ADDR_WIDTH, 31, 1)"
                    title              = "Base Address 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003e800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 2)"
                    drc                = "ext_base_addr_drc(s31_baddr_2, s31_addr_range_2, M_ADDR_WIDTH, 31, 2)"
                    title              = "Base Address 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003ec00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 3)"
                    drc                = "ext_base_addr_drc(s31_baddr_3, s31_addr_range_3, M_ADDR_WIDTH, 31, 3)"
                    title              = "Base Address 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003f000"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 4)"
                    drc                = "ext_base_addr_drc(s31_baddr_4, s31_addr_range_4, M_ADDR_WIDTH, 31, 4)"
                    title              = "Base Address 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003f400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 5)"
                    drc                = "ext_base_addr_drc(s31_baddr_5, s31_addr_range_5, M_ADDR_WIDTH, 31, 5)"
                    title              = "Base Address 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003f800"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 6)"
                    drc                = "ext_base_addr_drc(s31_baddr_6, s31_addr_range_6, M_ADDR_WIDTH, 31, 6)"
                    title              = "Base Address 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_baddr_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "0003fc00"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 7)"
                    drc                = "ext_base_addr_drc(s31_baddr_7, s31_addr_range_7, M_ADDR_WIDTH, 31, 7)"
                    title              = "Base Address 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_0"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 0)"
                    drc                = "ext_addr_range_drc(s31_addr_range_0, s31_baddr_0, 31, 0)"
                    title              = "Address Range 0"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_1"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 1)"
                    drc                = "ext_addr_range_drc(s31_addr_range_1, s31_baddr_1, 31, 1)"
                    title              = "Address Range 1"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_2"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 2)"
                    drc                = "ext_addr_range_drc(s31_addr_range_2, s31_baddr_2, 31, 2)"
                    title              = "Address Range 2"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_3"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 3)"
                    drc                = "ext_addr_range_drc(s31_addr_range_3, s31_baddr_3, 31, 3)"
                    title              = "Address Range 3"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_4"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 4)"
                    drc                = "ext_addr_range_drc(s31_addr_range_4, s31_baddr_4, 31, 4)"
                    title              = "Address Range 4"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_5"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 5)"
                    drc                = "ext_addr_range_drc(s31_addr_range_5, s31_baddr_5, 31, 5)"
                    title              = "Address Range 5"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_6"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 6)"
                    drc                = "ext_addr_range_drc(s31_addr_range_6, s31_baddr_6, 31, 6)"
                    title              = "Address Range 6"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "s31_addr_range_7"
                    type               = "input"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "(runtime_info.host_application != 'System Builder') and en_s31 and (S31_FRAGMENT_EN > 7)"
                    drc                = "ext_addr_range_drc(s31_addr_range_7, s31_baddr_7, 31, 7)"
                    title              = "Address Range 7"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "S31_BASE_ADDR"
                    type               = "param"
                    value_type         = "string"
                    default            = "000000400"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s31) else 'None'"
                    value_expr         = "ext_actual_base_addr(s31_baddr_0, s31_baddr_1, s31_baddr_2, s31_baddr_3, s31_baddr_4, s31_baddr_5, s31_baddr_6, s31_baddr_7, S31_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Base Address"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Main Settings"
                    id                 = "S31_ADDR_RANGE"
                    type               = "param"
                    value_type         = "string"
                    editable           = "False"
                    config_groups      = "'SystemBuilder' if(en_s31) else 'None'"
                    value_expr         = "ext_actual_base_addr(s31_addr_range_0, s31_addr_range_1, s31_addr_range_2, s31_addr_range_3, s31_addr_range_4, s31_addr_range_5, s31_addr_range_6, s31_addr_range_7, S31_FRAGMENT_EN)"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Address Range"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S0_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s0"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 0 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s0 and en_m1 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s0 and en_m1 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s0 and en_m2 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s0 and en_m3 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s0 and en_m4 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s0 and en_m5 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s0 and en_m6 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s0 and en_m7 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s0 and en_m8 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s0 and en_m9 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s0 and en_m10 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s0 and en_m11 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s0 and en_m12 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s0 and en_m13 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s0 and en_m14 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s0 and en_m15 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s0 and en_m16 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s0 and en_m17 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s0 and en_m18 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s0 and en_m19 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s0 and en_m20 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s0 and en_m21 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s0 and en_m22 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s0 and en_m23 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s0 and en_m24 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s0 and en_m25 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s0 and en_m26 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s0 and en_m27 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s0 and en_m28 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s0 and en_m29 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s0 and en_m30 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s0_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s0 and en_m31 and (S0_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(0,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 0 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 0 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S0_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(0,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S1_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s1"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 1 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s1 and en_m1 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s1 and en_m1 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s1 and en_m2 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s1 and en_m3 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s1 and en_m4 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s1 and en_m5 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s1 and en_m6 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s1 and en_m7 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s1 and en_m8 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s1 and en_m9 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s1 and en_m10 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s1 and en_m11 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s1 and en_m12 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s1 and en_m13 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s1 and en_m14 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s1 and en_m15 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s1 and en_m16 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s1 and en_m17 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s1 and en_m18 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s1 and en_m19 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s1 and en_m20 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s1 and en_m21 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s1 and en_m22 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s1 and en_m23 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s1 and en_m24 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s1 and en_m25 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s1 and en_m26 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s1 and en_m27 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s1 and en_m28 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s1 and en_m29 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s1 and en_m30 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s1_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s1 and en_m31 and (S1_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(1,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 1 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 1 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S1_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(1,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S2_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s2"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 2 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s2 and en_m1 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s2 and en_m1 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s2 and en_m2 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s2 and en_m3 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s2 and en_m4 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s2 and en_m5 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s2 and en_m6 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s2 and en_m7 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s2 and en_m8 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s2 and en_m9 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s2 and en_m10 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s2 and en_m11 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s2 and en_m12 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s2 and en_m13 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s2 and en_m14 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s2 and en_m15 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s2 and en_m16 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s2 and en_m17 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s2 and en_m18 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s2 and en_m19 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s2 and en_m20 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s2 and en_m21 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s2 and en_m22 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s2 and en_m23 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s2 and en_m24 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s2 and en_m25 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s2 and en_m26 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s2 and en_m27 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s2 and en_m28 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s2 and en_m29 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s2 and en_m30 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s2_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s2 and en_m31 and (S2_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(2,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 2 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 2 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S2_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(2,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S3_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s3"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 3 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s3 and en_m1 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s3 and en_m1 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s3 and en_m2 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s3 and en_m3 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s3 and en_m4 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s3 and en_m5 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s3 and en_m6 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s3 and en_m7 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s3 and en_m8 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s3 and en_m9 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s3 and en_m10 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s3 and en_m11 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s3 and en_m12 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s3 and en_m13 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s3 and en_m14 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s3 and en_m15 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s3 and en_m16 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s3 and en_m17 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s3 and en_m18 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s3 and en_m19 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s3 and en_m20 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s3 and en_m21 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s3 and en_m22 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s3 and en_m23 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s3 and en_m24 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s3 and en_m25 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s3 and en_m26 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s3 and en_m27 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s3 and en_m28 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s3 and en_m29 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s3 and en_m30 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s3_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s3 and en_m31 and (S3_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(3,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 3 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 3 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S3_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(3,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S4_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s4"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 4 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s4 and en_m1 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s4 and en_m1 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s4 and en_m2 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s4 and en_m3 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s4 and en_m4 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s4 and en_m5 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s4 and en_m6 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s4 and en_m7 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s4 and en_m8 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s4 and en_m9 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s4 and en_m10 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s4 and en_m11 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s4 and en_m12 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s4 and en_m13 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s4 and en_m14 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s4 and en_m15 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s4 and en_m16 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s4 and en_m17 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s4 and en_m18 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s4 and en_m19 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s4 and en_m20 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s4 and en_m21 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s4 and en_m22 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s4 and en_m23 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s4 and en_m24 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s4 and en_m25 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s4 and en_m26 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s4 and en_m27 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s4 and en_m28 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s4 and en_m29 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s4 and en_m30 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s4_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s4 and en_m31 and (S4_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(4,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 4 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 4 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S4_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(4,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S5_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s5"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 5 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s5 and en_m1 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s5 and en_m1 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s5 and en_m2 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s5 and en_m3 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s5 and en_m4 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s5 and en_m5 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s5 and en_m6 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s5 and en_m7 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s5 and en_m8 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s5 and en_m9 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s5 and en_m10 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s5 and en_m11 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s5 and en_m12 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s5 and en_m13 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s5 and en_m14 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s5 and en_m15 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s5 and en_m16 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s5 and en_m17 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s5 and en_m18 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s5 and en_m19 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s5 and en_m20 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s5 and en_m21 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s5 and en_m22 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s5 and en_m23 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s5 and en_m24 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s5 and en_m25 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s5 and en_m26 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s5 and en_m27 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s5 and en_m28 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s5 and en_m29 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s5 and en_m30 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s5_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s5 and en_m31 and (S5_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(5,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 5 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 5 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S5_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(5,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S6_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s6"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 6 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s6 and en_m1 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s6 and en_m1 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s6 and en_m2 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s6 and en_m3 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s6 and en_m4 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s6 and en_m5 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s6 and en_m6 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s6 and en_m7 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s6 and en_m8 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s6 and en_m9 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s6 and en_m10 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s6 and en_m11 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s6 and en_m12 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s6 and en_m13 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s6 and en_m14 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s6 and en_m15 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s6 and en_m16 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s6 and en_m17 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s6 and en_m18 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s6 and en_m19 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s6 and en_m20 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s6 and en_m21 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s6 and en_m22 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s6 and en_m23 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s6 and en_m24 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s6 and en_m25 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s6 and en_m26 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s6 and en_m27 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s6 and en_m28 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s6 and en_m29 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s6 and en_m30 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s6_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s6 and en_m31 and (S6_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(6,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 6 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 6 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S6_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(6,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S7_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s7"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 7 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s7 and en_m1 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s7 and en_m1 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s7 and en_m2 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s7 and en_m3 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s7 and en_m4 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s7 and en_m5 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s7 and en_m6 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s7 and en_m7 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s7 and en_m8 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s7 and en_m9 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s7 and en_m10 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s7 and en_m11 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s7 and en_m12 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s7 and en_m13 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s7 and en_m14 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s7 and en_m15 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s7 and en_m16 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s7 and en_m17 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s7 and en_m18 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s7 and en_m19 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s7 and en_m20 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s7 and en_m21 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s7 and en_m22 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s7 and en_m23 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s7 and en_m24 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s7 and en_m25 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s7 and en_m26 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s7 and en_m27 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s7 and en_m28 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s7 and en_m29 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s7 and en_m30 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s7_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s7 and en_m31 and (S7_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(7,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 7 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 7 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S7_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(7,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S8_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s8"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 8 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s8 and en_m1 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s8 and en_m1 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s8 and en_m2 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s8 and en_m3 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s8 and en_m4 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s8 and en_m5 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s8 and en_m6 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s8 and en_m7 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s8 and en_m8 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s8 and en_m9 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s8 and en_m10 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s8 and en_m11 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s8 and en_m12 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s8 and en_m13 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s8 and en_m14 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s8 and en_m15 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s8 and en_m16 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s8 and en_m17 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s8 and en_m18 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s8 and en_m19 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s8 and en_m20 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s8 and en_m21 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s8 and en_m22 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s8 and en_m23 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s8 and en_m24 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s8 and en_m25 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s8 and en_m26 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s8 and en_m27 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s8 and en_m28 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s8 and en_m29 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s8 and en_m30 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s8_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s8 and en_m31 and (S8_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(8,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 8 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 8 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S8_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(8,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S9_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s9"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 9 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s9 and en_m1 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s9 and en_m1 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s9 and en_m2 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s9 and en_m3 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s9 and en_m4 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s9 and en_m5 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s9 and en_m6 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s9 and en_m7 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s9 and en_m8 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s9 and en_m9 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s9 and en_m10 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s9 and en_m11 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s9 and en_m12 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s9 and en_m13 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s9 and en_m14 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s9 and en_m15 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s9 and en_m16 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s9 and en_m17 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s9 and en_m18 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s9 and en_m19 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s9 and en_m20 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s9 and en_m21 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s9 and en_m22 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s9 and en_m23 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s9 and en_m24 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s9 and en_m25 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s9 and en_m26 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s9 and en_m27 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s9 and en_m28 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s9 and en_m29 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s9 and en_m30 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s9_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s9 and en_m31 and (S9_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(9,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 9 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 9 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S9_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(9,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S10_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s10"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 10 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s10 and en_m1 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s10 and en_m1 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s10 and en_m2 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s10 and en_m3 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s10 and en_m4 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s10 and en_m5 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s10 and en_m6 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s10 and en_m7 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s10 and en_m8 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s10 and en_m9 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s10 and en_m10 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s10 and en_m11 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s10 and en_m12 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s10 and en_m13 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s10 and en_m14 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s10 and en_m15 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s10 and en_m16 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s10 and en_m17 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s10 and en_m18 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s10 and en_m19 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s10 and en_m20 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s10 and en_m21 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s10 and en_m22 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s10 and en_m23 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s10 and en_m24 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s10 and en_m25 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s10 and en_m26 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s10 and en_m27 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s10 and en_m28 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s10 and en_m29 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s10 and en_m30 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s10_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s10 and en_m31 and (S10_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(10,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 10 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 10 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S10_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(10,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S11_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s11"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 11 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s11 and en_m1 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s11 and en_m1 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s11 and en_m2 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s11 and en_m3 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s11 and en_m4 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s11 and en_m5 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s11 and en_m6 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s11 and en_m7 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s11 and en_m8 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s11 and en_m9 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s11 and en_m10 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s11 and en_m11 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s11 and en_m12 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s11 and en_m13 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s11 and en_m14 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s11 and en_m15 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s11 and en_m16 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s11 and en_m17 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s11 and en_m18 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s11 and en_m19 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s11 and en_m20 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s11 and en_m21 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s11 and en_m22 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s11 and en_m23 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s11 and en_m24 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s11 and en_m25 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s11 and en_m26 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s11 and en_m27 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s11 and en_m28 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s11 and en_m29 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s11 and en_m30 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s11_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s11 and en_m31 and (S11_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(11,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 11 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 11 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S11_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(11,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S12_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s12"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 12 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s12 and en_m1 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s12 and en_m1 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s12 and en_m2 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s12 and en_m3 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s12 and en_m4 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s12 and en_m5 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s12 and en_m6 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s12 and en_m7 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s12 and en_m8 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s12 and en_m9 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s12 and en_m10 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s12 and en_m11 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s12 and en_m12 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s12 and en_m13 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s12 and en_m14 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s12 and en_m15 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s12 and en_m16 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s12 and en_m17 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s12 and en_m18 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s12 and en_m19 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s12 and en_m20 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s12 and en_m21 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s12 and en_m22 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s12 and en_m23 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s12 and en_m24 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s12 and en_m25 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s12 and en_m26 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s12 and en_m27 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s12 and en_m28 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s12 and en_m29 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s12 and en_m30 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s12_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s12 and en_m31 and (S12_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(12,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 12 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 12 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S12_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(12,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S13_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s13"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 13 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s13 and en_m1 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s13 and en_m1 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s13 and en_m2 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s13 and en_m3 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s13 and en_m4 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s13 and en_m5 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s13 and en_m6 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s13 and en_m7 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s13 and en_m8 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s13 and en_m9 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s13 and en_m10 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s13 and en_m11 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s13 and en_m12 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s13 and en_m13 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s13 and en_m14 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s13 and en_m15 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s13 and en_m16 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s13 and en_m17 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s13 and en_m18 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s13 and en_m19 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s13 and en_m20 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s13 and en_m21 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s13 and en_m22 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s13 and en_m23 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s13 and en_m24 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s13 and en_m25 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s13 and en_m26 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s13 and en_m27 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s13 and en_m28 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s13 and en_m29 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s13 and en_m30 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s13_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s13 and en_m31 and (S13_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(13,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 13 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 13 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S13_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(13,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S14_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s14"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 14 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s14 and en_m1 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s14 and en_m1 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s14 and en_m2 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s14 and en_m3 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s14 and en_m4 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s14 and en_m5 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s14 and en_m6 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s14 and en_m7 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s14 and en_m8 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s14 and en_m9 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s14 and en_m10 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s14 and en_m11 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s14 and en_m12 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s14 and en_m13 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s14 and en_m14 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s14 and en_m15 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s14 and en_m16 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s14 and en_m17 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s14 and en_m18 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s14 and en_m19 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s14 and en_m20 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s14 and en_m21 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s14 and en_m22 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s14 and en_m23 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s14 and en_m24 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s14 and en_m25 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s14 and en_m26 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s14 and en_m27 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s14 and en_m28 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s14 and en_m29 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s14 and en_m30 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s14_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s14 and en_m31 and (S14_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(14,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 14 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 14 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S14_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(14,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S15_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s15"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 15 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s15 and en_m1 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s15 and en_m1 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s15 and en_m2 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s15 and en_m3 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s15 and en_m4 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s15 and en_m5 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s15 and en_m6 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s15 and en_m7 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s15 and en_m8 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s15 and en_m9 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s15 and en_m10 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s15 and en_m11 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s15 and en_m12 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s15 and en_m13 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s15 and en_m14 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s15 and en_m15 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s15 and en_m16 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s15 and en_m17 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s15 and en_m18 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s15 and en_m19 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s15 and en_m20 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s15 and en_m21 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s15 and en_m22 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s15 and en_m23 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s15 and en_m24 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s15 and en_m25 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s15 and en_m26 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s15 and en_m27 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s15 and en_m28 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s15 and en_m29 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s15 and en_m30 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s15_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s15 and en_m31 and (S15_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(15,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 15 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 15 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S15_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(15,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S16_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s16"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 16 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s16 and en_m1 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s16 and en_m1 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s16 and en_m2 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s16 and en_m3 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s16 and en_m4 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s16 and en_m5 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s16 and en_m6 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s16 and en_m7 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s16 and en_m8 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s16 and en_m9 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s16 and en_m10 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s16 and en_m11 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s16 and en_m12 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s16 and en_m13 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s16 and en_m14 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s16 and en_m15 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s16 and en_m16 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s16 and en_m17 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s16 and en_m18 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s16 and en_m19 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s16 and en_m20 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s16 and en_m21 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s16 and en_m22 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s16 and en_m23 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s16 and en_m24 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s16 and en_m25 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s16 and en_m26 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s16 and en_m27 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s16 and en_m28 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s16 and en_m29 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s16 and en_m30 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s16_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s16 and en_m31 and (S16_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(16,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 16 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 16 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S16_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(16,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S17_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s17"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 17 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s17 and en_m1 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s17 and en_m1 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s17 and en_m2 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s17 and en_m3 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s17 and en_m4 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s17 and en_m5 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s17 and en_m6 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s17 and en_m7 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s17 and en_m8 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s17 and en_m9 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s17 and en_m10 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s17 and en_m11 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s17 and en_m12 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s17 and en_m13 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s17 and en_m14 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s17 and en_m15 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s17 and en_m16 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s17 and en_m17 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s17 and en_m18 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s17 and en_m19 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s17 and en_m20 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s17 and en_m21 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s17 and en_m22 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s17 and en_m23 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s17 and en_m24 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s17 and en_m25 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s17 and en_m26 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s17 and en_m27 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s17 and en_m28 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s17 and en_m29 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s17 and en_m30 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s17_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s17 and en_m31 and (S17_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(17,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 17 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 17 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S17_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(17,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S18_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s18"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 18 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s18 and en_m1 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s18 and en_m1 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s18 and en_m2 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s18 and en_m3 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s18 and en_m4 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s18 and en_m5 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s18 and en_m6 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s18 and en_m7 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s18 and en_m8 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s18 and en_m9 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s18 and en_m10 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s18 and en_m11 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s18 and en_m12 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s18 and en_m13 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s18 and en_m14 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s18 and en_m15 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s18 and en_m16 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s18 and en_m17 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s18 and en_m18 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s18 and en_m19 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s18 and en_m20 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s18 and en_m21 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s18 and en_m22 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s18 and en_m23 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s18 and en_m24 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s18 and en_m25 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s18 and en_m26 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s18 and en_m27 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s18 and en_m28 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s18 and en_m29 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s18 and en_m30 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s18_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s18 and en_m31 and (S18_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(18,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 18 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 18 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S18_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(18,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S19_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s19"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 19 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s19 and en_m1 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s19 and en_m1 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s19 and en_m2 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s19 and en_m3 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s19 and en_m4 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s19 and en_m5 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s19 and en_m6 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s19 and en_m7 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s19 and en_m8 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s19 and en_m9 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s19 and en_m10 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s19 and en_m11 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s19 and en_m12 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s19 and en_m13 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s19 and en_m14 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s19 and en_m15 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s19 and en_m16 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s19 and en_m17 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s19 and en_m18 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s19 and en_m19 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s19 and en_m20 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s19 and en_m21 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s19 and en_m22 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s19 and en_m23 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s19 and en_m24 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s19 and en_m25 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s19 and en_m26 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s19 and en_m27 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s19 and en_m28 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s19 and en_m29 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s19 and en_m30 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s19_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s19 and en_m31 and (S19_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(19,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 19 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 19 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S19_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(19,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S20_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s20"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 20 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s20 and en_m1 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s20 and en_m1 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s20 and en_m2 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s20 and en_m3 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s20 and en_m4 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s20 and en_m5 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s20 and en_m6 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s20 and en_m7 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s20 and en_m8 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s20 and en_m9 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s20 and en_m10 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s20 and en_m11 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s20 and en_m12 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s20 and en_m13 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s20 and en_m14 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s20 and en_m15 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s20 and en_m16 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s20 and en_m17 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s20 and en_m18 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s20 and en_m19 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s20 and en_m20 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s20 and en_m21 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s20 and en_m22 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s20 and en_m23 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s20 and en_m24 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s20 and en_m25 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s20 and en_m26 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s20 and en_m27 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s20 and en_m28 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s20 and en_m29 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s20 and en_m30 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s20_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s20 and en_m31 and (S20_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(20,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 20 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 20 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S20_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(20,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S21_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s21"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 21 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s21 and en_m1 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s21 and en_m1 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s21 and en_m2 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s21 and en_m3 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s21 and en_m4 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s21 and en_m5 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s21 and en_m6 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s21 and en_m7 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s21 and en_m8 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s21 and en_m9 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s21 and en_m10 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s21 and en_m11 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s21 and en_m12 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s21 and en_m13 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s21 and en_m14 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s21 and en_m15 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s21 and en_m16 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s21 and en_m17 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s21 and en_m18 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s21 and en_m19 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s21 and en_m20 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s21 and en_m21 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s21 and en_m22 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s21 and en_m23 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s21 and en_m24 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s21 and en_m25 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s21 and en_m26 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s21 and en_m27 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s21 and en_m28 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s21 and en_m29 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s21 and en_m30 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s21_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s21 and en_m31 and (S21_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(21,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 21 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 21 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S21_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(21,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S22_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s22"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 22 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s22 and en_m1 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s22 and en_m1 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s22 and en_m2 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s22 and en_m3 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s22 and en_m4 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s22 and en_m5 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s22 and en_m6 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s22 and en_m7 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s22 and en_m8 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s22 and en_m9 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s22 and en_m10 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s22 and en_m11 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s22 and en_m12 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s22 and en_m13 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s22 and en_m14 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s22 and en_m15 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s22 and en_m16 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s22 and en_m17 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s22 and en_m18 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s22 and en_m19 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s22 and en_m20 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s22 and en_m21 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s22 and en_m22 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s22 and en_m23 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s22 and en_m24 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s22 and en_m25 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s22 and en_m26 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s22 and en_m27 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s22 and en_m28 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s22 and en_m29 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s22 and en_m30 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s22_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s22 and en_m31 and (S22_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(22,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 22 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 22 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S22_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(22,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S23_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s23"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 23 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s23 and en_m1 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s23 and en_m1 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s23 and en_m2 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s23 and en_m3 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s23 and en_m4 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s23 and en_m5 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s23 and en_m6 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s23 and en_m7 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s23 and en_m8 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s23 and en_m9 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s23 and en_m10 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s23 and en_m11 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s23 and en_m12 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s23 and en_m13 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s23 and en_m14 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s23 and en_m15 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s23 and en_m16 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s23 and en_m17 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s23 and en_m18 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s23 and en_m19 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s23 and en_m20 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s23 and en_m21 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s23 and en_m22 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s23 and en_m23 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s23 and en_m24 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s23 and en_m25 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s23 and en_m26 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s23 and en_m27 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s23 and en_m28 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s23 and en_m29 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s23 and en_m30 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s23_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s23 and en_m31 and (S23_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(23,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 23 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 23 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S23_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(23,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S24_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s24"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 24 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s24 and en_m1 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s24 and en_m1 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s24 and en_m2 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s24 and en_m3 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s24 and en_m4 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s24 and en_m5 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s24 and en_m6 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s24 and en_m7 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s24 and en_m8 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s24 and en_m9 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s24 and en_m10 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s24 and en_m11 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s24 and en_m12 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s24 and en_m13 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s24 and en_m14 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s24 and en_m15 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s24 and en_m16 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s24 and en_m17 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s24 and en_m18 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s24 and en_m19 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s24 and en_m20 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s24 and en_m21 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s24 and en_m22 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s24 and en_m23 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s24 and en_m24 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s24 and en_m25 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s24 and en_m26 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s24 and en_m27 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s24 and en_m28 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s24 and en_m29 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s24 and en_m30 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s24_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s24 and en_m31 and (S24_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(24,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 24 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 24 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S24_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(24,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S25_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s25"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 25 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s25 and en_m1 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s25 and en_m1 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s25 and en_m2 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s25 and en_m3 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s25 and en_m4 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s25 and en_m5 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s25 and en_m6 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s25 and en_m7 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s25 and en_m8 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s25 and en_m9 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s25 and en_m10 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s25 and en_m11 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s25 and en_m12 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s25 and en_m13 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s25 and en_m14 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s25 and en_m15 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s25 and en_m16 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s25 and en_m17 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s25 and en_m18 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s25 and en_m19 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s25 and en_m20 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s25 and en_m21 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s25 and en_m22 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s25 and en_m23 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s25 and en_m24 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s25 and en_m25 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s25 and en_m26 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s25 and en_m27 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s25 and en_m28 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s25 and en_m29 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s25 and en_m30 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s25_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s25 and en_m31 and (S25_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(25,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 25 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 25 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S25_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(25,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S26_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s26"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 26 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s26 and en_m1 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s26 and en_m1 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s26 and en_m2 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s26 and en_m3 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s26 and en_m4 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s26 and en_m5 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s26 and en_m6 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s26 and en_m7 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s26 and en_m8 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s26 and en_m9 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s26 and en_m10 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s26 and en_m11 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s26 and en_m12 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s26 and en_m13 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s26 and en_m14 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s26 and en_m15 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s26 and en_m16 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s26 and en_m17 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s26 and en_m18 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s26 and en_m19 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s26 and en_m20 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s26 and en_m21 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s26 and en_m22 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s26 and en_m23 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s26 and en_m24 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s26 and en_m25 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s26 and en_m26 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s26 and en_m27 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s26 and en_m28 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s26 and en_m29 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s26 and en_m30 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s26_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s26 and en_m31 and (S26_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(26,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 26 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 26 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S26_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(26,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S27_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s27"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 27 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s27 and en_m1 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s27 and en_m1 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s27 and en_m2 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s27 and en_m3 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s27 and en_m4 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s27 and en_m5 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s27 and en_m6 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s27 and en_m7 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s27 and en_m8 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s27 and en_m9 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s27 and en_m10 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s27 and en_m11 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s27 and en_m12 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s27 and en_m13 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s27 and en_m14 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s27 and en_m15 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s27 and en_m16 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s27 and en_m17 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s27 and en_m18 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s27 and en_m19 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s27 and en_m20 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s27 and en_m21 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s27 and en_m22 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s27 and en_m23 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s27 and en_m24 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s27 and en_m25 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s27 and en_m26 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s27 and en_m27 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s27 and en_m28 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s27 and en_m29 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s27 and en_m30 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s27_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s27 and en_m31 and (S27_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(27,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 27 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 27 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S27_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(27,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S28_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s28"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 28 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s28 and en_m1 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s28 and en_m1 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s28 and en_m2 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s28 and en_m3 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s28 and en_m4 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s28 and en_m5 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s28 and en_m6 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s28 and en_m7 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s28 and en_m8 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s28 and en_m9 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s28 and en_m10 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s28 and en_m11 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s28 and en_m12 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s28 and en_m13 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s28 and en_m14 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s28 and en_m15 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s28 and en_m16 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s28 and en_m17 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s28 and en_m18 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s28 and en_m19 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s28 and en_m20 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s28 and en_m21 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s28 and en_m22 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s28 and en_m23 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s28 and en_m24 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s28 and en_m25 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s28 and en_m26 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s28 and en_m27 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s28 and en_m28 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s28 and en_m29 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s28 and en_m30 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s28_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s28 and en_m31 and (S28_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(28,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 28 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 28 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S28_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(28,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S29_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s29"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 29 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s29 and en_m1 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s29 and en_m1 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s29 and en_m2 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s29 and en_m3 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s29 and en_m4 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s29 and en_m5 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s29 and en_m6 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s29 and en_m7 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s29 and en_m8 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s29 and en_m9 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s29 and en_m10 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s29 and en_m11 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s29 and en_m12 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s29 and en_m13 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s29 and en_m14 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s29 and en_m15 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s29 and en_m16 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s29 and en_m17 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s29 and en_m18 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s29 and en_m19 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s29 and en_m20 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s29 and en_m21 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s29 and en_m22 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s29 and en_m23 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s29 and en_m24 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s29 and en_m25 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s29 and en_m26 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s29 and en_m27 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s29 and en_m28 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s29 and en_m29 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s29 and en_m30 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s29_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s29 and en_m31 and (S29_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(29,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 29 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 29 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S29_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(29,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S30_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s30"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 30 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s30 and en_m1 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s30 and en_m1 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s30 and en_m2 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s30 and en_m3 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s30 and en_m4 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s30 and en_m5 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s30 and en_m6 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s30 and en_m7 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s30 and en_m8 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s30 and en_m9 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s30 and en_m10 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s30 and en_m11 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s30 and en_m12 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s30 and en_m13 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s30 and en_m14 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s30 and en_m15 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s30 and en_m16 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s30 and en_m17 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s30 and en_m18 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s30 and en_m19 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s30 and en_m20 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s30 and en_m21 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s30 and en_m22 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s30 and en_m23 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s30 and en_m24 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s30 and en_m25 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s30 and en_m26 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s30 and en_m27 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s30 and en_m28 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s30 and en_m29 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s30 and en_m30 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s30_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s30 and en_m31 and (S30_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(30,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 30 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 30 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S30_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(30,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S31_ARBITER_SCHEME"
                    type               = "param"
                    value_type         = "string"
                    default            = "3'd0"
                    editable           = "en_s31"
                    options            = "ext_arb_scheme_options()"
                    output_formatter   = "nostr"
                    title              = "Arbiter Scheme"
    />
    
    <!-- Subordinate 31 Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m00_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    editable           = "en_s31 and en_m1 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,0)"
                    title              = "Manager 0 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m01_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "1"
                    editable           = "en_s31 and en_m1 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,1)"
                    title              = "Manager 1 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m02_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "2"
                    editable           = "en_s31 and en_m2 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,2)"
                    title              = "Manager 2 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m03_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "3"
                    editable           = "en_s31 and en_m3 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,3)"
                    title              = "Manager 3 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m04_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "4"
                    editable           = "en_s31 and en_m4 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,4)"
                    title              = "Manager 4 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m05_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "5"
                    editable           = "en_s31 and en_m5 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,5)"
                    title              = "Manager 5 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m06_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "6"
                    editable           = "en_s31 and en_m6 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,6)"
                    title              = "Manager 6 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m07_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "7"
                    editable           = "en_s31 and en_m7 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,7)"
                    title              = "Manager 7 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m08_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "8"
                    editable           = "en_s31 and en_m8 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,8)"
                    title              = "Manager 8 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m09_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "9"
                    editable           = "en_s31 and en_m9 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,9)"
                    title              = "Manager 9 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m10_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "10"
                    editable           = "en_s31 and en_m10 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,10)"
                    title              = "Manager 10 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m11_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "11"
                    editable           = "en_s31 and en_m11 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,11)"
                    title              = "Manager 11 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m12_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "12"
                    editable           = "en_s31 and en_m12 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,12)"
                    title              = "Manager 12 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m13_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "13"
                    editable           = "en_s31 and en_m13 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,13)"
                    title              = "Manager 13 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m14_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "14"
                    editable           = "en_s31 and en_m14 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,14)"
                    title              = "Manager 14 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m15_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "15"
                    editable           = "en_s31 and en_m15 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,15)"
                    title              = "Manager 15 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m16_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "16"
                    editable           = "en_s31 and en_m16 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,16)"
                    title              = "Manager 16 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m17_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "17"
                    editable           = "en_s31 and en_m17 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,17)"
                    title              = "Manager 17 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m18_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "18"
                    editable           = "en_s31 and en_m18 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,18)"
                    title              = "Manager 18 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m19_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "19"
                    editable           = "en_s31 and en_m19 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,19)"
                    title              = "Manager 19 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m20_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "20"
                    editable           = "en_s31 and en_m20 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,20)"
                    title              = "Manager 20 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m21_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "21"
                    editable           = "en_s31 and en_m21 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,21)"
                    title              = "Manager 21 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m22_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "22"
                    editable           = "en_s31 and en_m22 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,22)"
                    title              = "Manager 22 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m23_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "23"
                    editable           = "en_s31 and en_m23 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,23)"
                    title              = "Manager 23 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m24_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "24"
                    editable           = "en_s31 and en_m24 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,24)"
                    title              = "Manager 24 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m25_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "25"
                    editable           = "en_s31 and en_m25 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,25)"
                    title              = "Manager 25 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m26_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "26"
                    editable           = "en_s31 and en_m26 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,26)"
                    title              = "Manager 26 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m27_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "27"
                    editable           = "en_s31 and en_m27 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,27)"
                    title              = "Manager 27 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m28_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "28"
                    editable           = "en_s31 and en_m28 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,28)"
                    title              = "Manager 28 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m29_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "29"
                    editable           = "en_s31 and en_m29 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,29)"
                    title              = "Manager 29 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m30_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "30"
                    editable           = "en_s31 and en_m30 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,30)"
                    title              = "Manager 30 Priority"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "s31_m31_pid"
                    type               = "input"
                    value_type         = "int"
                    default            = "31"
                    editable           = "en_s31 and en_m31 and (S31_ARBITER_SCHEME == '3\'d1')"
                    options            = "range(0,32)"
                    drc                = "ext_prio_idx_drc(31,31)"
                    title              = "Manager 31 Priority"
    />
    <!-- Subordinate 31 Actual Priority Index -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Subordinate 31 Settings"
                    group2             = "Manager Priority Settings"
                    id                 = "S31_M_PRIO_IDX"
                    type               = "param"
                    value_type         = "string"
                    value_expr         = "ext_actual_prio_list(31,m_prio_width,TOTAL_MASTER_CNT)"
                    editable           = "False"
                    output_formatter   = "nostr"
                    title              = "INFO: Actual Prio Index List"
    />
    <!-- Max Burst Size Settings-->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S0_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s0"
                    title              = "Subordinate 0 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S1_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s1"
                    title              = "Subordinate 1 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S2_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s2"
                    title              = "Subordinate 2 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S3_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s3"
                    title              = "Subordinate 3 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S4_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s4"
                    title              = "Subordinate 4 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S5_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s5"
                    title              = "Subordinate 5 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S6_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s6"
                    title              = "Subordinate 6 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S7_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s7"
                    title              = "Subordinate 7 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S8_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s8"
                    title              = "Subordinate 8 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S9_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s9"
                    title              = "Subordinate 9 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S10_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s10"
                    title              = "Subordinate 10 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S11_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s11"
                    title              = "Subordinate 11 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S12_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s12"
                    title              = "Subordinate 12 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S13_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s13"
                    title              = "Subordinate 13 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S14_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s14"
                    title              = "Subordinate 14 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S15_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s15"
                    title              = "Subordinate 15 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S16_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s16"
                    title              = "Subordinate 16 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S17_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s17"
                    title              = "Subordinate 17 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S18_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s18"
                    title              = "Subordinate 18 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S19_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s19"
                    title              = "Subordinate 19 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S20_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s20"
                    title              = "Subordinate 20 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S21_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s21"
                    title              = "Subordinate 21 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S22_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s22"
                    title              = "Subordinate 22 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S23_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s23"
                    title              = "Subordinate 23 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S24_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s24"
                    title              = "Subordinate 24 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S25_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s25"
                    title              = "Subordinate 25 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S26_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s26"
                    title              = "Subordinate 26 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S27_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s27"
                    title              = "Subordinate 27 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S28_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s28"
                    title              = "Subordinate 28 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S29_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s29"
                    title              = "Subordinate 29 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S30_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s30"
                    title              = "Subordinate 30 Max Burst Size"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Max Burst Size Subordinate Settings"
                    group2             = "Max Burst Size Settings"
                    id                 = "S31_MAX_BURST_SIZE"
                    type               = "param"
                    value_type         = "int"
                    options            = "[0, 32, 64, 128, 256]"
                    default            = "0"
                    hidden             = "TOTAL_MASTER_CNT == 1"
                    editable           = "en_s31"
                    title              = "Subordinate 31 Max Burst Size"
    />
    <!-- Hidden Parameters -->
    <!-- Manager Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m0"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(1)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M0 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m1"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(2)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M1 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m2"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(3)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M2 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m3"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(4)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M3 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m4"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(5)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M4 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m5"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(6)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M5 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m6"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(7)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M6 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m7"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(8)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M7 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m8"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(9)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M8 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m9"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(10)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M9 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m10"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(11)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M10 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m11"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(12)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M11 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m12"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(13)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M12 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m13"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(14)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M13 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m14"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(15)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M14 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m15"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(16)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M15 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m16"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(17)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M16 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m17"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(18)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M17 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m18"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(19)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M18 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m19"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(20)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M19 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m20"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(21)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M20 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m21"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(22)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M21 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m22"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(23)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M22 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m23"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(24)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M23 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m24"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(25)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M24 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m25"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(26)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M25 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m26"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(27)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M26 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m27"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(28)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M27 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m28"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(29)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M28 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m29"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(30)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M29 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m30"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(31)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M30 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_m31"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_master_range(32)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "M31 Enable/Disable"
    />
    <!-- Subordinate Settings -->
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s0"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(1)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S0 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s1"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(2)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S1 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s2"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(3)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S2 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s3"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(4)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S3 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s4"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(5)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S4 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s5"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(6)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S5 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s6"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(7)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S6 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s7"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(8)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S7 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s8"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(9)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S8 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s9"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(10)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S9 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s10"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(11)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S10 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s11"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(12)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S11 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s12"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(13)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S12 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s13"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(14)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S13 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s14"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(15)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S14 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s15"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(16)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S15 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s16"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(17)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S16 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s17"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(18)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S17 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s18"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(19)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S18 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s19"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(20)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S19 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s20"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(21)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S20 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s21"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(22)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S21 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s22"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(23)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S22 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s23"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(24)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S23 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s24"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(25)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S24 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s25"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(26)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S25 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s26"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(27)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S26 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s27"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(28)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S27 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s28"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(29)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S28 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s29"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(30)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S29 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s30"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(31)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S30 Enable/Disable"
    />
    <lsccip:setting conn_mod           = "lscc_ahbl_interconnect"
                    group1             = "Hidden Parameters"
                    id                 = "en_s31"
                    type               = "input"
                    value_type         = "int"
                    default            = "0"
                    value_expr         = "ext_check_slave_range(32)"
                    editable           = "False"
                    hidden             = "True"
                    title              = "S31 Enable/Disable"
    />
  </lsccip:settings>


  <lsccip:ports>
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 name          = "ahbl_hclk_i"
                 dir           = "in"
                 port_type     = "clock"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 name          = "ahbl_hresetn_i"
                 dir           = "in"
                 port_type     = "reset"
    />
    <!-- Manager 31 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_s31_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(31,M_ADDR_WIDTH)"
                 name          = "ahbl_s31_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(31,3)"
                 name          = "ahbl_s31_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(31,3)"
                 name          = "ahbl_s31_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_s31_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(31,4)"
                 name          = "ahbl_s31_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(31,2)"
                 name          = "ahbl_s31_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(31,DATA_WIDTH)"
                 name          = "ahbl_s31_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_s31_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_s31_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_s31_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_s31_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(31,DATA_WIDTH)"
                 name          = "ahbl_s31_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m31"
                 bus_interface = "AHBL_S31"
    />
    <!-- Subordinate 31 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_m31_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_m31_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(31,DATA_WIDTH)"
                 name          = "ahbl_m31_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_m31_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(31,M_ADDR_WIDTH)"
                 name          = "ahbl_m31_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(31,3)"
                 name          = "ahbl_m31_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(31,3)"
                 name          = "ahbl_m31_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_m31_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(31,4)"
                 name          = "ahbl_m31_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(31,2)"
                 name          = "ahbl_m31_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(31,DATA_WIDTH)"
                 name          = "ahbl_m31_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_m31_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(31,1)"
                 name          = "ahbl_m31_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s31"
                 bus_interface = "AHBL_M31"
    />
    <!-- Manager 30 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_s30_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(30,M_ADDR_WIDTH)"
                 name          = "ahbl_s30_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(30,3)"
                 name          = "ahbl_s30_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(30,3)"
                 name          = "ahbl_s30_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_s30_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(30,4)"
                 name          = "ahbl_s30_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(30,2)"
                 name          = "ahbl_s30_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(30,DATA_WIDTH)"
                 name          = "ahbl_s30_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_s30_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_s30_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_s30_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_s30_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(30,DATA_WIDTH)"
                 name          = "ahbl_s30_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m30"
                 bus_interface = "AHBL_S30"
    />
    <!-- Subordinate 30 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_m30_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_m30_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(30,DATA_WIDTH)"
                 name          = "ahbl_m30_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_m30_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(30,M_ADDR_WIDTH)"
                 name          = "ahbl_m30_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(30,3)"
                 name          = "ahbl_m30_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(30,3)"
                 name          = "ahbl_m30_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_m30_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(30,4)"
                 name          = "ahbl_m30_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(30,2)"
                 name          = "ahbl_m30_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(30,DATA_WIDTH)"
                 name          = "ahbl_m30_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_m30_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(30,1)"
                 name          = "ahbl_m30_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s30"
                 bus_interface = "AHBL_M30"
    />
    <!-- Manager 29 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_s29_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(29,M_ADDR_WIDTH)"
                 name          = "ahbl_s29_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(29,3)"
                 name          = "ahbl_s29_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(29,3)"
                 name          = "ahbl_s29_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_s29_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(29,4)"
                 name          = "ahbl_s29_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(29,2)"
                 name          = "ahbl_s29_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(29,DATA_WIDTH)"
                 name          = "ahbl_s29_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_s29_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_s29_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_s29_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_s29_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(29,DATA_WIDTH)"
                 name          = "ahbl_s29_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m29"
                 bus_interface = "AHBL_S29"
    />
    <!-- Subordinate 29 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_m29_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_m29_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(29,DATA_WIDTH)"
                 name          = "ahbl_m29_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_m29_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(29,M_ADDR_WIDTH)"
                 name          = "ahbl_m29_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(29,3)"
                 name          = "ahbl_m29_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(29,3)"
                 name          = "ahbl_m29_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_m29_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(29,4)"
                 name          = "ahbl_m29_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(29,2)"
                 name          = "ahbl_m29_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(29,DATA_WIDTH)"
                 name          = "ahbl_m29_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_m29_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(29,1)"
                 name          = "ahbl_m29_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s29"
                 bus_interface = "AHBL_M29"
    />
    <!-- Manager 28 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_s28_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(28,M_ADDR_WIDTH)"
                 name          = "ahbl_s28_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(28,3)"
                 name          = "ahbl_s28_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(28,3)"
                 name          = "ahbl_s28_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_s28_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(28,4)"
                 name          = "ahbl_s28_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(28,2)"
                 name          = "ahbl_s28_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(28,DATA_WIDTH)"
                 name          = "ahbl_s28_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_s28_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_s28_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_s28_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_s28_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(28,DATA_WIDTH)"
                 name          = "ahbl_s28_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m28"
                 bus_interface = "AHBL_S28"
    />
    <!-- Subordinate 28 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_m28_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_m28_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(28,DATA_WIDTH)"
                 name          = "ahbl_m28_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_m28_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(28,M_ADDR_WIDTH)"
                 name          = "ahbl_m28_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(28,3)"
                 name          = "ahbl_m28_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(28,3)"
                 name          = "ahbl_m28_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_m28_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(28,4)"
                 name          = "ahbl_m28_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(28,2)"
                 name          = "ahbl_m28_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(28,DATA_WIDTH)"
                 name          = "ahbl_m28_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_m28_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(28,1)"
                 name          = "ahbl_m28_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s28"
                 bus_interface = "AHBL_M28"
    />
    <!-- Manager 27 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_s27_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(27,M_ADDR_WIDTH)"
                 name          = "ahbl_s27_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(27,3)"
                 name          = "ahbl_s27_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(27,3)"
                 name          = "ahbl_s27_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_s27_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(27,4)"
                 name          = "ahbl_s27_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(27,2)"
                 name          = "ahbl_s27_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(27,DATA_WIDTH)"
                 name          = "ahbl_s27_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_s27_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_s27_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_s27_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_s27_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(27,DATA_WIDTH)"
                 name          = "ahbl_s27_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m27"
                 bus_interface = "AHBL_S27"
    />
    <!-- Subordinate 27 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_m27_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_m27_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(27,DATA_WIDTH)"
                 name          = "ahbl_m27_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_m27_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(27,M_ADDR_WIDTH)"
                 name          = "ahbl_m27_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(27,3)"
                 name          = "ahbl_m27_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(27,3)"
                 name          = "ahbl_m27_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_m27_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(27,4)"
                 name          = "ahbl_m27_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(27,2)"
                 name          = "ahbl_m27_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(27,DATA_WIDTH)"
                 name          = "ahbl_m27_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_m27_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(27,1)"
                 name          = "ahbl_m27_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s27"
                 bus_interface = "AHBL_M27"
    />
    <!-- Manager 26 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_s26_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(26,M_ADDR_WIDTH)"
                 name          = "ahbl_s26_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(26,3)"
                 name          = "ahbl_s26_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(26,3)"
                 name          = "ahbl_s26_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_s26_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(26,4)"
                 name          = "ahbl_s26_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(26,2)"
                 name          = "ahbl_s26_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(26,DATA_WIDTH)"
                 name          = "ahbl_s26_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_s26_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_s26_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_s26_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_s26_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(26,DATA_WIDTH)"
                 name          = "ahbl_s26_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m26"
                 bus_interface = "AHBL_S26"
    />
    <!-- Subordinate 26 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_m26_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_m26_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(26,DATA_WIDTH)"
                 name          = "ahbl_m26_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_m26_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(26,M_ADDR_WIDTH)"
                 name          = "ahbl_m26_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(26,3)"
                 name          = "ahbl_m26_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(26,3)"
                 name          = "ahbl_m26_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_m26_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(26,4)"
                 name          = "ahbl_m26_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(26,2)"
                 name          = "ahbl_m26_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(26,DATA_WIDTH)"
                 name          = "ahbl_m26_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_m26_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(26,1)"
                 name          = "ahbl_m26_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s26"
                 bus_interface = "AHBL_M26"
    />
    <!-- Manager 25 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_s25_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(25,M_ADDR_WIDTH)"
                 name          = "ahbl_s25_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(25,3)"
                 name          = "ahbl_s25_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(25,3)"
                 name          = "ahbl_s25_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_s25_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(25,4)"
                 name          = "ahbl_s25_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(25,2)"
                 name          = "ahbl_s25_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(25,DATA_WIDTH)"
                 name          = "ahbl_s25_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_s25_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_s25_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_s25_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_s25_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(25,DATA_WIDTH)"
                 name          = "ahbl_s25_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m25"
                 bus_interface = "AHBL_S25"
    />
    <!-- Subordinate 25 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_m25_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_m25_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(25,DATA_WIDTH)"
                 name          = "ahbl_m25_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_m25_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(25,M_ADDR_WIDTH)"
                 name          = "ahbl_m25_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(25,3)"
                 name          = "ahbl_m25_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(25,3)"
                 name          = "ahbl_m25_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_m25_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(25,4)"
                 name          = "ahbl_m25_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(25,2)"
                 name          = "ahbl_m25_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(25,DATA_WIDTH)"
                 name          = "ahbl_m25_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_m25_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(25,1)"
                 name          = "ahbl_m25_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s25"
                 bus_interface = "AHBL_M25"
    />
    <!-- Manager 24 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_s24_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(24,M_ADDR_WIDTH)"
                 name          = "ahbl_s24_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(24,3)"
                 name          = "ahbl_s24_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(24,3)"
                 name          = "ahbl_s24_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_s24_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(24,4)"
                 name          = "ahbl_s24_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(24,2)"
                 name          = "ahbl_s24_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(24,DATA_WIDTH)"
                 name          = "ahbl_s24_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_s24_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_s24_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_s24_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_s24_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(24,DATA_WIDTH)"
                 name          = "ahbl_s24_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m24"
                 bus_interface = "AHBL_S24"
    />
    <!-- Subordinate 24 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_m24_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_m24_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(24,DATA_WIDTH)"
                 name          = "ahbl_m24_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_m24_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(24,M_ADDR_WIDTH)"
                 name          = "ahbl_m24_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(24,3)"
                 name          = "ahbl_m24_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(24,3)"
                 name          = "ahbl_m24_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_m24_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(24,4)"
                 name          = "ahbl_m24_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(24,2)"
                 name          = "ahbl_m24_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(24,DATA_WIDTH)"
                 name          = "ahbl_m24_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_m24_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(24,1)"
                 name          = "ahbl_m24_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s24"
                 bus_interface = "AHBL_M24"
    />
    <!-- Manager 23 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_s23_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(23,M_ADDR_WIDTH)"
                 name          = "ahbl_s23_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(23,3)"
                 name          = "ahbl_s23_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(23,3)"
                 name          = "ahbl_s23_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_s23_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(23,4)"
                 name          = "ahbl_s23_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(23,2)"
                 name          = "ahbl_s23_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(23,DATA_WIDTH)"
                 name          = "ahbl_s23_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_s23_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_s23_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_s23_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_s23_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(23,DATA_WIDTH)"
                 name          = "ahbl_s23_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m23"
                 bus_interface = "AHBL_S23"
    />
    <!-- Subordinate 23 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_m23_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_m23_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(23,DATA_WIDTH)"
                 name          = "ahbl_m23_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_m23_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(23,M_ADDR_WIDTH)"
                 name          = "ahbl_m23_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(23,3)"
                 name          = "ahbl_m23_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(23,3)"
                 name          = "ahbl_m23_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_m23_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(23,4)"
                 name          = "ahbl_m23_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(23,2)"
                 name          = "ahbl_m23_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(23,DATA_WIDTH)"
                 name          = "ahbl_m23_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_m23_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(23,1)"
                 name          = "ahbl_m23_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s23"
                 bus_interface = "AHBL_M23"
    />
    <!-- Manager 22 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_s22_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(22,M_ADDR_WIDTH)"
                 name          = "ahbl_s22_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(22,3)"
                 name          = "ahbl_s22_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(22,3)"
                 name          = "ahbl_s22_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_s22_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(22,4)"
                 name          = "ahbl_s22_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(22,2)"
                 name          = "ahbl_s22_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(22,DATA_WIDTH)"
                 name          = "ahbl_s22_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_s22_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_s22_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_s22_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_s22_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(22,DATA_WIDTH)"
                 name          = "ahbl_s22_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m22"
                 bus_interface = "AHBL_S22"
    />
    <!-- Subordinate 22 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_m22_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_m22_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(22,DATA_WIDTH)"
                 name          = "ahbl_m22_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_m22_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(22,M_ADDR_WIDTH)"
                 name          = "ahbl_m22_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(22,3)"
                 name          = "ahbl_m22_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(22,3)"
                 name          = "ahbl_m22_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_m22_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(22,4)"
                 name          = "ahbl_m22_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(22,2)"
                 name          = "ahbl_m22_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(22,DATA_WIDTH)"
                 name          = "ahbl_m22_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_m22_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(22,1)"
                 name          = "ahbl_m22_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s22"
                 bus_interface = "AHBL_M22"
    />
    <!-- Manager 21 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_s21_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(21,M_ADDR_WIDTH)"
                 name          = "ahbl_s21_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(21,3)"
                 name          = "ahbl_s21_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(21,3)"
                 name          = "ahbl_s21_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_s21_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(21,4)"
                 name          = "ahbl_s21_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(21,2)"
                 name          = "ahbl_s21_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(21,DATA_WIDTH)"
                 name          = "ahbl_s21_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_s21_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_s21_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_s21_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_s21_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(21,DATA_WIDTH)"
                 name          = "ahbl_s21_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m21"
                 bus_interface = "AHBL_S21"
    />
    <!-- Subordinate 21 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_m21_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_m21_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(21,DATA_WIDTH)"
                 name          = "ahbl_m21_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_m21_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(21,M_ADDR_WIDTH)"
                 name          = "ahbl_m21_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(21,3)"
                 name          = "ahbl_m21_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(21,3)"
                 name          = "ahbl_m21_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_m21_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(21,4)"
                 name          = "ahbl_m21_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(21,2)"
                 name          = "ahbl_m21_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(21,DATA_WIDTH)"
                 name          = "ahbl_m21_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_m21_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(21,1)"
                 name          = "ahbl_m21_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s21"
                 bus_interface = "AHBL_M21"
    />
    <!-- Manager 20 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_s20_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(20,M_ADDR_WIDTH)"
                 name          = "ahbl_s20_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(20,3)"
                 name          = "ahbl_s20_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(20,3)"
                 name          = "ahbl_s20_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_s20_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(20,4)"
                 name          = "ahbl_s20_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(20,2)"
                 name          = "ahbl_s20_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(20,DATA_WIDTH)"
                 name          = "ahbl_s20_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_s20_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_s20_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_s20_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_s20_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(20,DATA_WIDTH)"
                 name          = "ahbl_s20_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m20"
                 bus_interface = "AHBL_S20"
    />
    <!-- Subordinate 20 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_m20_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_m20_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(20,DATA_WIDTH)"
                 name          = "ahbl_m20_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_m20_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(20,M_ADDR_WIDTH)"
                 name          = "ahbl_m20_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(20,3)"
                 name          = "ahbl_m20_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(20,3)"
                 name          = "ahbl_m20_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_m20_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(20,4)"
                 name          = "ahbl_m20_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(20,2)"
                 name          = "ahbl_m20_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(20,DATA_WIDTH)"
                 name          = "ahbl_m20_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_m20_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(20,1)"
                 name          = "ahbl_m20_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s20"
                 bus_interface = "AHBL_M20"
    />
    <!-- Manager 19 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_s19_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(19,M_ADDR_WIDTH)"
                 name          = "ahbl_s19_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(19,3)"
                 name          = "ahbl_s19_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(19,3)"
                 name          = "ahbl_s19_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_s19_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(19,4)"
                 name          = "ahbl_s19_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(19,2)"
                 name          = "ahbl_s19_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(19,DATA_WIDTH)"
                 name          = "ahbl_s19_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_s19_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_s19_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_s19_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_s19_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(19,DATA_WIDTH)"
                 name          = "ahbl_s19_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m19"
                 bus_interface = "AHBL_S19"
    />
    <!-- Subordinate 19 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_m19_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_m19_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(19,DATA_WIDTH)"
                 name          = "ahbl_m19_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_m19_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(19,M_ADDR_WIDTH)"
                 name          = "ahbl_m19_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(19,3)"
                 name          = "ahbl_m19_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(19,3)"
                 name          = "ahbl_m19_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_m19_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(19,4)"
                 name          = "ahbl_m19_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(19,2)"
                 name          = "ahbl_m19_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(19,DATA_WIDTH)"
                 name          = "ahbl_m19_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_m19_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(19,1)"
                 name          = "ahbl_m19_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s19"
                 bus_interface = "AHBL_M19"
    />
    <!-- Manager 18 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_s18_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(18,M_ADDR_WIDTH)"
                 name          = "ahbl_s18_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(18,3)"
                 name          = "ahbl_s18_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(18,3)"
                 name          = "ahbl_s18_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_s18_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(18,4)"
                 name          = "ahbl_s18_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(18,2)"
                 name          = "ahbl_s18_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(18,DATA_WIDTH)"
                 name          = "ahbl_s18_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_s18_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_s18_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_s18_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_s18_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(18,DATA_WIDTH)"
                 name          = "ahbl_s18_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m18"
                 bus_interface = "AHBL_S18"
    />
    <!-- Subordinate 18 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_m18_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_m18_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(18,DATA_WIDTH)"
                 name          = "ahbl_m18_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_m18_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(18,M_ADDR_WIDTH)"
                 name          = "ahbl_m18_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(18,3)"
                 name          = "ahbl_m18_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(18,3)"
                 name          = "ahbl_m18_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_m18_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(18,4)"
                 name          = "ahbl_m18_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(18,2)"
                 name          = "ahbl_m18_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(18,DATA_WIDTH)"
                 name          = "ahbl_m18_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_m18_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(18,1)"
                 name          = "ahbl_m18_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s18"
                 bus_interface = "AHBL_M18"
    />
    <!-- Manager 17 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_s17_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(17,M_ADDR_WIDTH)"
                 name          = "ahbl_s17_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(17,3)"
                 name          = "ahbl_s17_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(17,3)"
                 name          = "ahbl_s17_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_s17_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(17,4)"
                 name          = "ahbl_s17_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(17,2)"
                 name          = "ahbl_s17_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(17,DATA_WIDTH)"
                 name          = "ahbl_s17_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_s17_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_s17_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_s17_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_s17_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(17,DATA_WIDTH)"
                 name          = "ahbl_s17_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m17"
                 bus_interface = "AHBL_S17"
    />
    <!-- Subordinate 17 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_m17_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_m17_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(17,DATA_WIDTH)"
                 name          = "ahbl_m17_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_m17_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(17,M_ADDR_WIDTH)"
                 name          = "ahbl_m17_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(17,3)"
                 name          = "ahbl_m17_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(17,3)"
                 name          = "ahbl_m17_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_m17_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(17,4)"
                 name          = "ahbl_m17_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(17,2)"
                 name          = "ahbl_m17_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(17,DATA_WIDTH)"
                 name          = "ahbl_m17_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_m17_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(17,1)"
                 name          = "ahbl_m17_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s17"
                 bus_interface = "AHBL_M17"
    />
    <!-- Manager 16 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_s16_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(16,M_ADDR_WIDTH)"
                 name          = "ahbl_s16_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(16,3)"
                 name          = "ahbl_s16_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(16,3)"
                 name          = "ahbl_s16_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_s16_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(16,4)"
                 name          = "ahbl_s16_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(16,2)"
                 name          = "ahbl_s16_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(16,DATA_WIDTH)"
                 name          = "ahbl_s16_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_s16_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_s16_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_s16_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_s16_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(16,DATA_WIDTH)"
                 name          = "ahbl_s16_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m16"
                 bus_interface = "AHBL_S16"
    />
    <!-- Subordinate 16 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_m16_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_m16_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(16,DATA_WIDTH)"
                 name          = "ahbl_m16_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_m16_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(16,M_ADDR_WIDTH)"
                 name          = "ahbl_m16_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(16,3)"
                 name          = "ahbl_m16_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(16,3)"
                 name          = "ahbl_m16_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_m16_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(16,4)"
                 name          = "ahbl_m16_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(16,2)"
                 name          = "ahbl_m16_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(16,DATA_WIDTH)"
                 name          = "ahbl_m16_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_m16_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(16,1)"
                 name          = "ahbl_m16_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s16"
                 bus_interface = "AHBL_M16"
    />
    <!-- Manager 15 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_s15_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(15,M_ADDR_WIDTH)"
                 name          = "ahbl_s15_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(15,3)"
                 name          = "ahbl_s15_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(15,3)"
                 name          = "ahbl_s15_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_s15_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(15,4)"
                 name          = "ahbl_s15_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(15,2)"
                 name          = "ahbl_s15_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(15,DATA_WIDTH)"
                 name          = "ahbl_s15_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_s15_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_s15_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_s15_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_s15_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(15,DATA_WIDTH)"
                 name          = "ahbl_s15_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m15"
                 bus_interface = "AHBL_S15"
    />
    <!-- Subordinate 15 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_m15_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_m15_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(15,DATA_WIDTH)"
                 name          = "ahbl_m15_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_m15_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(15,M_ADDR_WIDTH)"
                 name          = "ahbl_m15_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(15,3)"
                 name          = "ahbl_m15_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(15,3)"
                 name          = "ahbl_m15_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_m15_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(15,4)"
                 name          = "ahbl_m15_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(15,2)"
                 name          = "ahbl_m15_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(15,DATA_WIDTH)"
                 name          = "ahbl_m15_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_m15_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(15,1)"
                 name          = "ahbl_m15_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s15"
                 bus_interface = "AHBL_M15"
    />
    <!-- Manager 14 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_s14_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(14,M_ADDR_WIDTH)"
                 name          = "ahbl_s14_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(14,3)"
                 name          = "ahbl_s14_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(14,3)"
                 name          = "ahbl_s14_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_s14_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(14,4)"
                 name          = "ahbl_s14_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(14,2)"
                 name          = "ahbl_s14_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(14,DATA_WIDTH)"
                 name          = "ahbl_s14_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_s14_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_s14_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_s14_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_s14_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(14,DATA_WIDTH)"
                 name          = "ahbl_s14_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m14"
                 bus_interface = "AHBL_S14"
    />
    <!-- Subordinate 14 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_m14_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_m14_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(14,DATA_WIDTH)"
                 name          = "ahbl_m14_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_m14_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(14,M_ADDR_WIDTH)"
                 name          = "ahbl_m14_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(14,3)"
                 name          = "ahbl_m14_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(14,3)"
                 name          = "ahbl_m14_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_m14_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(14,4)"
                 name          = "ahbl_m14_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(14,2)"
                 name          = "ahbl_m14_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(14,DATA_WIDTH)"
                 name          = "ahbl_m14_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_m14_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(14,1)"
                 name          = "ahbl_m14_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s14"
                 bus_interface = "AHBL_M14"
    />
    <!-- Manager 13 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_s13_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(13,M_ADDR_WIDTH)"
                 name          = "ahbl_s13_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(13,3)"
                 name          = "ahbl_s13_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(13,3)"
                 name          = "ahbl_s13_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_s13_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(13,4)"
                 name          = "ahbl_s13_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(13,2)"
                 name          = "ahbl_s13_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(13,DATA_WIDTH)"
                 name          = "ahbl_s13_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_s13_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_s13_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_s13_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_s13_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(13,DATA_WIDTH)"
                 name          = "ahbl_s13_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m13"
                 bus_interface = "AHBL_S13"
    />
    <!-- Subordinate 13 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_m13_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_m13_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(13,DATA_WIDTH)"
                 name          = "ahbl_m13_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_m13_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(13,M_ADDR_WIDTH)"
                 name          = "ahbl_m13_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(13,3)"
                 name          = "ahbl_m13_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(13,3)"
                 name          = "ahbl_m13_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_m13_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(13,4)"
                 name          = "ahbl_m13_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(13,2)"
                 name          = "ahbl_m13_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(13,DATA_WIDTH)"
                 name          = "ahbl_m13_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_m13_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(13,1)"
                 name          = "ahbl_m13_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s13"
                 bus_interface = "AHBL_M13"
    />
    <!-- Manager 12 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_s12_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(12,M_ADDR_WIDTH)"
                 name          = "ahbl_s12_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(12,3)"
                 name          = "ahbl_s12_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(12,3)"
                 name          = "ahbl_s12_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_s12_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(12,4)"
                 name          = "ahbl_s12_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(12,2)"
                 name          = "ahbl_s12_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(12,DATA_WIDTH)"
                 name          = "ahbl_s12_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_s12_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_s12_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_s12_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_s12_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(12,DATA_WIDTH)"
                 name          = "ahbl_s12_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m12"
                 bus_interface = "AHBL_S12"
    />
    <!-- Subordinate 12 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_m12_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_m12_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(12,DATA_WIDTH)"
                 name          = "ahbl_m12_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_m12_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(12,M_ADDR_WIDTH)"
                 name          = "ahbl_m12_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(12,3)"
                 name          = "ahbl_m12_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(12,3)"
                 name          = "ahbl_m12_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_m12_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(12,4)"
                 name          = "ahbl_m12_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(12,2)"
                 name          = "ahbl_m12_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(12,DATA_WIDTH)"
                 name          = "ahbl_m12_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_m12_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(12,1)"
                 name          = "ahbl_m12_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s12"
                 bus_interface = "AHBL_M12"
    />
    <!-- Manager 11 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_s11_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(11,M_ADDR_WIDTH)"
                 name          = "ahbl_s11_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(11,3)"
                 name          = "ahbl_s11_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(11,3)"
                 name          = "ahbl_s11_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_s11_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(11,4)"
                 name          = "ahbl_s11_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(11,2)"
                 name          = "ahbl_s11_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(11,DATA_WIDTH)"
                 name          = "ahbl_s11_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_s11_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_s11_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_s11_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_s11_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(11,DATA_WIDTH)"
                 name          = "ahbl_s11_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m11"
                 bus_interface = "AHBL_S11"
    />
    <!-- Subordinate 11 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_m11_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_m11_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(11,DATA_WIDTH)"
                 name          = "ahbl_m11_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_m11_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(11,M_ADDR_WIDTH)"
                 name          = "ahbl_m11_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(11,3)"
                 name          = "ahbl_m11_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(11,3)"
                 name          = "ahbl_m11_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_m11_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(11,4)"
                 name          = "ahbl_m11_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(11,2)"
                 name          = "ahbl_m11_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(11,DATA_WIDTH)"
                 name          = "ahbl_m11_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_m11_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(11,1)"
                 name          = "ahbl_m11_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s11"
                 bus_interface = "AHBL_M11"
    />
    <!-- Manager 10 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_s10_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(10,M_ADDR_WIDTH)"
                 name          = "ahbl_s10_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(10,3)"
                 name          = "ahbl_s10_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(10,3)"
                 name          = "ahbl_s10_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_s10_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(10,4)"
                 name          = "ahbl_s10_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(10,2)"
                 name          = "ahbl_s10_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(10,DATA_WIDTH)"
                 name          = "ahbl_s10_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_s10_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_s10_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_s10_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_s10_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(10,DATA_WIDTH)"
                 name          = "ahbl_s10_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m10"
                 bus_interface = "AHBL_S10"
    />
    <!-- Subordinate 10 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_m10_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_m10_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(10,DATA_WIDTH)"
                 name          = "ahbl_m10_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_m10_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(10,M_ADDR_WIDTH)"
                 name          = "ahbl_m10_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(10,3)"
                 name          = "ahbl_m10_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(10,3)"
                 name          = "ahbl_m10_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_m10_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(10,4)"
                 name          = "ahbl_m10_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(10,2)"
                 name          = "ahbl_m10_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(10,DATA_WIDTH)"
                 name          = "ahbl_m10_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_m10_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(10,1)"
                 name          = "ahbl_m10_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s10"
                 bus_interface = "AHBL_M10"
    />
    <!-- Manager 9 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_s09_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(9,M_ADDR_WIDTH)"
                 name          = "ahbl_s09_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(9,3)"
                 name          = "ahbl_s09_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(9,3)"
                 name          = "ahbl_s09_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_s09_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(9,4)"
                 name          = "ahbl_s09_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(9,2)"
                 name          = "ahbl_s09_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(9,DATA_WIDTH)"
                 name          = "ahbl_s09_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_s09_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_s09_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_s09_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_s09_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(9,DATA_WIDTH)"
                 name          = "ahbl_s09_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m9"
                 bus_interface = "AHBL_S09"
    />
    <!-- Subordinate 9 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_m09_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_m09_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(9,DATA_WIDTH)"
                 name          = "ahbl_m09_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_m09_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(9,M_ADDR_WIDTH)"
                 name          = "ahbl_m09_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(9,3)"
                 name          = "ahbl_m09_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(9,3)"
                 name          = "ahbl_m09_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_m09_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(9,4)"
                 name          = "ahbl_m09_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(9,2)"
                 name          = "ahbl_m09_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(9,DATA_WIDTH)"
                 name          = "ahbl_m09_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_m09_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(9,1)"
                 name          = "ahbl_m09_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s9"
                 bus_interface = "AHBL_M09"
    />
    <!-- Manager 8 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_s08_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(8,M_ADDR_WIDTH)"
                 name          = "ahbl_s08_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(8,3)"
                 name          = "ahbl_s08_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(8,3)"
                 name          = "ahbl_s08_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_s08_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(8,4)"
                 name          = "ahbl_s08_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(8,2)"
                 name          = "ahbl_s08_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(8,DATA_WIDTH)"
                 name          = "ahbl_s08_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_s08_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_s08_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_s08_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_s08_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(8,DATA_WIDTH)"
                 name          = "ahbl_s08_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m8"
                 bus_interface = "AHBL_S08"
    />
    <!-- Subordinate 8 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_m08_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_m08_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(8,DATA_WIDTH)"
                 name          = "ahbl_m08_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_m08_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(8,M_ADDR_WIDTH)"
                 name          = "ahbl_m08_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(8,3)"
                 name          = "ahbl_m08_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(8,3)"
                 name          = "ahbl_m08_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_m08_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(8,4)"
                 name          = "ahbl_m08_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(8,2)"
                 name          = "ahbl_m08_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(8,DATA_WIDTH)"
                 name          = "ahbl_m08_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_m08_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(8,1)"
                 name          = "ahbl_m08_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s8"
                 bus_interface = "AHBL_M08"
    />
    <!-- Manager 7 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_s07_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(7,M_ADDR_WIDTH)"
                 name          = "ahbl_s07_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(7,3)"
                 name          = "ahbl_s07_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(7,3)"
                 name          = "ahbl_s07_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_s07_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(7,4)"
                 name          = "ahbl_s07_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(7,2)"
                 name          = "ahbl_s07_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(7,DATA_WIDTH)"
                 name          = "ahbl_s07_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_s07_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_s07_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_s07_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_s07_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(7,DATA_WIDTH)"
                 name          = "ahbl_s07_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m7"
                 bus_interface = "AHBL_S07"
    />
    <!-- Subordinate 7 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_m07_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_m07_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(7,DATA_WIDTH)"
                 name          = "ahbl_m07_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_m07_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(7,M_ADDR_WIDTH)"
                 name          = "ahbl_m07_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(7,3)"
                 name          = "ahbl_m07_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(7,3)"
                 name          = "ahbl_m07_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_m07_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(7,4)"
                 name          = "ahbl_m07_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(7,2)"
                 name          = "ahbl_m07_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(7,DATA_WIDTH)"
                 name          = "ahbl_m07_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_m07_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(7,1)"
                 name          = "ahbl_m07_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s7"
                 bus_interface = "AHBL_M07"
    />
    <!-- Manager 6 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_s06_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(6,M_ADDR_WIDTH)"
                 name          = "ahbl_s06_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(6,3)"
                 name          = "ahbl_s06_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(6,3)"
                 name          = "ahbl_s06_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_s06_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(6,4)"
                 name          = "ahbl_s06_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(6,2)"
                 name          = "ahbl_s06_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(6,DATA_WIDTH)"
                 name          = "ahbl_s06_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_s06_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_s06_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_s06_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_s06_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(6,DATA_WIDTH)"
                 name          = "ahbl_s06_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m6"
                 bus_interface = "AHBL_S06"
    />
    <!-- Subordinate 6 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_m06_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_m06_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(6,DATA_WIDTH)"
                 name          = "ahbl_m06_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_m06_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(6,M_ADDR_WIDTH)"
                 name          = "ahbl_m06_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(6,3)"
                 name          = "ahbl_m06_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(6,3)"
                 name          = "ahbl_m06_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_m06_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(6,4)"
                 name          = "ahbl_m06_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(6,2)"
                 name          = "ahbl_m06_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(6,DATA_WIDTH)"
                 name          = "ahbl_m06_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_m06_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(6,1)"
                 name          = "ahbl_m06_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s6"
                 bus_interface = "AHBL_M06"
    />
    <!-- Manager 5 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_s05_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(5,M_ADDR_WIDTH)"
                 name          = "ahbl_s05_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(5,3)"
                 name          = "ahbl_s05_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(5,3)"
                 name          = "ahbl_s05_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_s05_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(5,4)"
                 name          = "ahbl_s05_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(5,2)"
                 name          = "ahbl_s05_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(5,DATA_WIDTH)"
                 name          = "ahbl_s05_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_s05_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_s05_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_s05_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_s05_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(5,DATA_WIDTH)"
                 name          = "ahbl_s05_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m5"
                 bus_interface = "AHBL_S05"
    />
    <!-- Subordinate 5 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_m05_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_m05_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(5,DATA_WIDTH)"
                 name          = "ahbl_m05_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_m05_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(5,M_ADDR_WIDTH)"
                 name          = "ahbl_m05_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(5,3)"
                 name          = "ahbl_m05_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(5,3)"
                 name          = "ahbl_m05_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_m05_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(5,4)"
                 name          = "ahbl_m05_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(5,2)"
                 name          = "ahbl_m05_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(5,DATA_WIDTH)"
                 name          = "ahbl_m05_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_m05_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(5,1)"
                 name          = "ahbl_m05_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s5"
                 bus_interface = "AHBL_M05"
    />
    <!-- Manager 4 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_s04_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(4,M_ADDR_WIDTH)"
                 name          = "ahbl_s04_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(4,3)"
                 name          = "ahbl_s04_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(4,3)"
                 name          = "ahbl_s04_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_s04_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(4,4)"
                 name          = "ahbl_s04_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(4,2)"
                 name          = "ahbl_s04_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(4,DATA_WIDTH)"
                 name          = "ahbl_s04_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_s04_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_s04_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_s04_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_s04_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(4,DATA_WIDTH)"
                 name          = "ahbl_s04_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m4"
                 bus_interface = "AHBL_S04"
    />
    <!-- Subordinate 4 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_m04_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_m04_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(4,DATA_WIDTH)"
                 name          = "ahbl_m04_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_m04_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(4,M_ADDR_WIDTH)"
                 name          = "ahbl_m04_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(4,3)"
                 name          = "ahbl_m04_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(4,3)"
                 name          = "ahbl_m04_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_m04_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(4,4)"
                 name          = "ahbl_m04_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(4,2)"
                 name          = "ahbl_m04_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(4,DATA_WIDTH)"
                 name          = "ahbl_m04_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_m04_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(4,1)"
                 name          = "ahbl_m04_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s4"
                 bus_interface = "AHBL_M04"
    />
    <!-- Manager 3 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_s03_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(3,M_ADDR_WIDTH)"
                 name          = "ahbl_s03_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(3,3)"
                 name          = "ahbl_s03_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(3,3)"
                 name          = "ahbl_s03_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_s03_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(3,4)"
                 name          = "ahbl_s03_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(3,2)"
                 name          = "ahbl_s03_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(3,DATA_WIDTH)"
                 name          = "ahbl_s03_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_s03_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_s03_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_s03_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_s03_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(3,DATA_WIDTH)"
                 name          = "ahbl_s03_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m3"
                 bus_interface = "AHBL_S03"
    />
    <!-- Subordinate 3 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_m03_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_m03_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(3,DATA_WIDTH)"
                 name          = "ahbl_m03_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_m03_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(3,M_ADDR_WIDTH)"
                 name          = "ahbl_m03_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(3,3)"
                 name          = "ahbl_m03_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(3,3)"
                 name          = "ahbl_m03_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_m03_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(3,4)"
                 name          = "ahbl_m03_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(3,2)"
                 name          = "ahbl_m03_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(3,DATA_WIDTH)"
                 name          = "ahbl_m03_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_m03_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(3,1)"
                 name          = "ahbl_m03_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s3"
                 bus_interface = "AHBL_M03"
    />
    <!-- Manager 2 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_s02_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(2,M_ADDR_WIDTH)"
                 name          = "ahbl_s02_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(2,3)"
                 name          = "ahbl_s02_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(2,3)"
                 name          = "ahbl_s02_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_s02_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(2,4)"
                 name          = "ahbl_s02_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(2,2)"
                 name          = "ahbl_s02_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(2,DATA_WIDTH)"
                 name          = "ahbl_s02_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_s02_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_s02_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_s02_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_s02_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(2,DATA_WIDTH)"
                 name          = "ahbl_s02_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m2"
                 bus_interface = "AHBL_S02"
    />
    <!-- Subordinate 2 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_m02_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_m02_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(2,DATA_WIDTH)"
                 name          = "ahbl_m02_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_m02_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(2,M_ADDR_WIDTH)"
                 name          = "ahbl_m02_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(2,3)"
                 name          = "ahbl_m02_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(2,3)"
                 name          = "ahbl_m02_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_m02_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(2,4)"
                 name          = "ahbl_m02_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(2,2)"
                 name          = "ahbl_m02_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(2,DATA_WIDTH)"
                 name          = "ahbl_m02_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_m02_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(2,1)"
                 name          = "ahbl_m02_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s2"
                 bus_interface = "AHBL_M02"
    />
    <!-- Manager 1 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_s01_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(1,M_ADDR_WIDTH)"
                 name          = "ahbl_s01_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(1,3)"
                 name          = "ahbl_s01_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(1,3)"
                 name          = "ahbl_s01_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_s01_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(1,4)"
                 name          = "ahbl_s01_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(1,2)"
                 name          = "ahbl_s01_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(1,DATA_WIDTH)"
                 name          = "ahbl_s01_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_s01_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_s01_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_s01_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_s01_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(1,DATA_WIDTH)"
                 name          = "ahbl_s01_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m1"
                 bus_interface = "AHBL_S01"
    />
    <!-- Subordinate 1 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_m01_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_m01_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(1,DATA_WIDTH)"
                 name          = "ahbl_m01_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_m01_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(1,M_ADDR_WIDTH)"
                 name          = "ahbl_m01_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(1,3)"
                 name          = "ahbl_m01_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(1,3)"
                 name          = "ahbl_m01_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_m01_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(1,4)"
                 name          = "ahbl_m01_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(1,2)"
                 name          = "ahbl_m01_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(1,DATA_WIDTH)"
                 name          = "ahbl_m01_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_m01_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(1,1)"
                 name          = "ahbl_m01_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s1"
                 bus_interface = "AHBL_M01"
    />
    <!-- Manager 0 Interface -->
    <!-- Manager-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_slv_i"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_s00_hsel_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_slv_i"
                 conn_range    = "ext_get_port_range(0,M_ADDR_WIDTH)"
                 name          = "ahbl_s00_haddr_slv_i"
                 dir           = "in"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_slv_i"
                 conn_range    = "ext_get_port_range(0,3)"
                 name          = "ahbl_s00_hburst_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_slv_i"
                 conn_range    = "ext_get_port_range(0,3)"
                 name          = "ahbl_s00_hsize_slv_i"
                 dir           = "in"
                 range         = "(2,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_slv_i"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_s00_hmastlock_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_slv_i"
                 conn_range    = "ext_get_port_range(0,4)"
                 name          = "ahbl_s00_hprot_slv_i"
                 dir           = "in"
                 range         = "(3,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_slv_i"
                 conn_range    = "ext_get_port_range(0,2)"
                 name          = "ahbl_s00_htrans_slv_i"
                 dir           = "in"
                 range         = "(1,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_slv_i"
                 conn_range    = "ext_get_port_range(0,DATA_WIDTH)"
                 name          = "ahbl_s00_hwdata_slv_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_slv_i"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_s00_hwrite_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_slv_i"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_s00_hready_slv_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <!-- Manager-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hreadyout_slv_o"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_s00_hreadyout_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_slv_o"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_s00_hresp_slv_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_slv_o"
                 conn_range    = "ext_get_port_range(0,DATA_WIDTH)"
                 name          = "ahbl_s00_hrdata_slv_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_m0"
                 bus_interface = "AHBL_S00"
    />
    <!-- Subordinate 0 Interface -->
    <!-- Subordinate-Side Input -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_i"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_m00_hready_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hresp_mstr_i"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_m00_hresp_mstr_i"
                 dir           = "in"
                 range         = "(0,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hrdata_mstr_i"
                 conn_range    = "ext_get_port_range(0,DATA_WIDTH)"
                 name          = "ahbl_m00_hrdata_mstr_i"
                 dir           = "in"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <!-- Subordinate-Side Output -->
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsel_mstr_o"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_m00_hsel_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_haddr_mstr_o"
                 conn_range    = "ext_get_port_range(0,M_ADDR_WIDTH)"
                 name          = "ahbl_m00_haddr_mstr_o"
                 dir           = "out"
                 range         = "(M_ADDR_WIDTH-1,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hburst_mstr_o"
                 conn_range    = "ext_get_port_range(0,3)"
                 name          = "ahbl_m00_hburst_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hsize_mstr_o"
                 conn_range    = "ext_get_port_range(0,3)"
                 name          = "ahbl_m00_hsize_mstr_o"
                 dir           = "out"
                 range         = "(2,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hmastlock_mstr_o"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_m00_hmastlock_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hprot_mstr_o"
                 conn_range    = "ext_get_port_range(0,4)"
                 name          = "ahbl_m00_hprot_mstr_o"
                 dir           = "out"
                 range         = "(3,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_htrans_mstr_o"
                 conn_range    = "ext_get_port_range(0,2)"
                 name          = "ahbl_m00_htrans_mstr_o"
                 dir           = "out"
                 range         = "(1,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwdata_mstr_o"
                 conn_range    = "ext_get_port_range(0,DATA_WIDTH)"
                 name          = "ahbl_m00_hwdata_mstr_o"
                 dir           = "out"
                 range         = "(DATA_WIDTH-1,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hwrite_mstr_o"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_m00_hwrite_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
    <lsccip:port conn_mod      = "lscc_ahbl_interconnect"
                 conn_port     = "ahbl_hready_mstr_o"
                 conn_range    = "ext_get_port_range(0,1)"
                 name          = "ahbl_m00_hready_mstr_o"
                 dir           = "out"
                 range         = "(0,0)"
                 dangling      = "not en_s0"
                 bus_interface = "AHBL_M00"
    />
  </lsccip:ports>


  <xi:include href="bus_interface.xml" parse="xml" />

      <lsccip:parameters>
          <lsccip:parameter>
              <lsccip:name>SB_COMPONENT_TYPE</lsccip:name>
              <lsccip:value>Bus</lsccip:value>
          </lsccip:parameter>
          <lsccip:parameter parameterId="SB_MIN_ADDR_RANGE" type="int">
              <lsccip:name>SB_MIN_ADDR_RANGE</lsccip:name>
              <lsccip:value>'h400</lsccip:value>
          </lsccip:parameter>
      </lsccip:parameters>

</lsccip:ip>